文献速递胸部CT

局部晚期肺癌放疗深吸气屏气:INHALE试验中分次内几何不确定性的验证

Deep inspiration breath hold in locally advanced lung cancer radiotherapy: validation of intrafractional geometric uncertainties in the INHALE trial.
PubMed 文献 · Br J Radiol · 2019-09-26

INHALE前瞻性试验纳入局部晚期非小细胞肺癌患者,用光学跟踪引导深吸气屏气(DIBH)放疗,通过三次连续DIBH CT评估分次内肿瘤位置可重复性并计算PTV外扩。60/69例(87%)为初始DIBH依从,50/69例(72%)为全程DIBH依从;系统误差与随机误差小但与此前预试验不同,导致两项研究PTV外扩略有差异。

要点

  • 局部晚期NSCLC患者DIBH依从性高:初始87%、全程72%。
  • 连续DIBH间系统误差与随机误差小,但与此前预试验结果不同。
  • DIBH不能消除靶区位置不确定性,仅减轻,需在外扩中考虑。

核心结论

  • DIBH依从性和靶区位置可重复性高,但验证研究提示PTV外扩需在更大代表性患者队列中设计。
  • DIBH不能消除而是减轻靶区位置不确定性,需在治疗外扩中加以考虑。

研究设计与样本

  • 前瞻性试验,纳入局部晚期非小细胞肺癌患者88例,其中69例接受根治性放疗。
  • 采用光学跟踪引导的自愿、视觉引导DIBH,患者接受三次连续DIBH CT扫描用于放疗计划。
  • 评估外周肿瘤、淋巴结位置的分次内不确定性及两者间差异运动,并据此计算PTV外扩。

诊断标准与关键数值

  • 完成全部DIBH影像且肿瘤位置可重复性<8 mm者定义为初始DIBH依从。
  • 全程治疗均执行DIBH者定义为全程DIBH依从。
  • 连续DIBH间系统误差与随机误差小,但与此前预试验结果不同,致两项研究PTV外扩略有差异。

临床应用与阅片要点

  • DIBH放疗计划在7例患者中不优于对照,3例在治疗中失去DIBH能力,最终50/69例(72%)全程DIBH依从。
  • 作者指出PTV外扩设计应基于更大代表性患者群体的数据。

局限性

  • 系统误差与随机误差虽小但与此前预试验结果不同,导致两项研究PTV外扩略有差异。
  • 作者指出需在更大、代表性患者队列中设计PTV外扩。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Patients with locally advanced non-small cell lung cancer (NSCLC) were included in a prospective trial for radiotherapy in deep inspiration breath hold (DIBH). We evaluated DIBH compliance and target position reproducibility.

METHODS: Voluntary, visually guided DIBHs were performed with optical tracking. Patients underwent three consecutive DIBH CT scans for radiotherapy planning. We evaluated the intrafractional uncertainties in the position of the peripheral tumour, lymph nodes and differential motion between them, enabling PTV margins calculation. Patients who underwent all DIBH imaging and had tumour position reproducibility <8 mm were up-front DIBH compliant. Patients who performed DIBHs throughout the treatment course were overall DIBH compliant. Clinical parameters and DIBH-related uncertainties were validated against our earlier pilot study.

RESULTS: 69 of 88 included patients received definitive radiotherapy. 60/69 patients (87%) were up-front DIBH compliant. DIBH plan was not superior in seven patients and three lost DIBH ability during the treatment, leaving 50/69 patients (72%) overall DIBH compliant.The systematic and random errors between consecutive DIBHs were small but differed from the pilot study findings. This led to slightly different PTV margins between the two studies.

CONCLUSIONS: DIBH compliance and reproducibility was high. Still, this validation study highlighted the necessity of designing PTV margins in larger, representative patient cohorts.

ADVANCES IN KNOWLEDGE: We demonstrated high DIBH compliance in locally advanced NSCLC patients. DIBH does not eliminate but mitigates the target position uncertainty, which needs to be accounted for in treatment margins. Margin design should be based on data from larger representative patient groups.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Josipovic M, Aznar MC, Thomsen JB, et al. Deep inspiration breath hold in locally advanced lung cancer radiotherapy: validation of intrafractional geometric uncertainties in the INHALE trial. Br J Radiol. 2019. PMID: 31544478. doi:10.1259/bjr.20190569

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。