在肿瘤患者常规CT检查中应用自动展开肋骨图像后处理提高良恶性肋骨病变的检出
该回顾性研究纳入1008例于2018年7月至2019年1月在本机构接受胸部CT的肿瘤患者,比较自动展开肋骨图像后处理与传统横断面CT阅读对肋骨病变的检出效能,参考标准为FDG PET、Ga-DOMITATE PET/CT、骨扫描或影像随访(>6个月)。展开肋骨图像检出305个病变,传统阅读检出104个;对恶性肋骨病变,展开肋骨图像敏感度97.7%、特异度98.5%、阳性预测值96.6%、阴性预测值99%,传统阅读分别为76.4%、100%、92.7%、90.5%。作者结论认为展开肋骨图像重组对肋骨病变检出显著优于传统横断面CT阅读,应应用于所有患者,尤其是肿瘤背景患者。
要点
- 展开肋骨图像检出305个病变,传统横断面CT仅检出104个。
- 恶性肋骨病变敏感度展开肋骨97.7% vs 传统76.4%,特异度98.5% vs 100%。
- 展开肋骨算法对硬化性肋骨病变及直径>1 cm病变的检出显著更优(P<0.01)。
核心结论
- 展开肋骨图像重组对肋骨病变的检出显著优于传统横断面CT阅读,作者建议所有患者尤其肿瘤背景患者使用。
研究设计与样本
- 回顾性研究,纳入1008例住院和门诊患者(年龄63.66±14.25岁,范围18.67-95.67岁;女性405例、男性603例),于2018年7月至2019年1月在本机构接受胸部CT。
- CT协议:120 kV;100 mAs;矩阵512×512;准直0.6 mm;重建层厚3 mm和1 mm,分别采用软组织空间分辨率核(I30f)和锐利核(B70f)。
- 传统诊断使用横断面图像及3 mm层厚冠状面重组;1 mm层厚图像数据自动后处理为三维展开肋骨,约4周后独立阅读。
- 参考标准为F-FDG PET、Ga-DOMITATE PET/CT、骨扫描或影像随访(>6个月)。
关键影像表现/征象
- 展开肋骨图像检出305个肋骨病变,传统横断面CT检出104个;其中恶性89个、良性202个。
- 展开肋骨图像对直径<1 cm(P<0.02)和>1 cm(P<0.007)的恶性肋骨病变检出均显著。
- 展开肋骨算法对硬化性肋骨病变及直径>1 cm病变的检出显著更优(P<0.01)。
诊断标准与关键数值
- 恶性肋骨病变:展开肋骨图像敏感度97.7%、特异度98.5%、阳性预测值96.6%、阴性预测值99%。
- 恶性肋骨病变:传统横断面图像敏感度76.4%、特异度100%、阳性预测值92.7%、阴性预测值90.5%。
临床应用与阅片要点
- 展开肋骨图像重组可提高肋骨病变检出,尤其对硬化性病变和直径>1 cm病变。
- 作者建议所有患者尤其肿瘤背景患者使用展开肋骨图像重组。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to evaluate the performance of the automated computed tomography (CT) postprocessing software unfolded rib images for improved detection of both benign and malignant rib lesions during routine diagnostic workup of oncological patients.
MATERIALS AND METHODS: One thousand eight in-patients and out-patients (63.66 ± 14.25 years; range, 18.67-95.67 years; 405 females and 603 males), undergoing chest CT between July 2018 to January 2019 at our institution, were retrospectively evaluated. Patients underwent chest CT alone or as part of a whole-body CT staging/restaging. The CT protocol consisted of the following: 120 kV; 100 mAs; matrix, 512 × 512; collimation, 0.6 mm; reconstructed section thickness of 3 mm and 1 mm using a soft tissue spatial resolution kernel (I30f) and a sharp kernel (B70f). Both transversal image data sets were used for "conventional" diagnosis including coronal reformates with 3-mm slice thickness. One-millimeter slice thickness image data sets of all patients were additionally directed from the scanner to a computational server where they were automatically postprocessed to 3-dimensional unfolded ribs. The "unfolding" of the rib using the centerline as an axis allows a synchronous display and rotation of all ribs by mouse scrolling. These postprocessed image data sets were evaluated in a separate reading session (approximately 4 weeks later). The readers had no information about the underlying medical history or clinical presentation. They were asked to record the lesion number, site of involvement along the rib (proximal, body, distal), number of the involved ribs, and the character of the lesion in terms of lytic versus sclerotic versus mixed lytic/sclerotic. The standard of reference was F-FDG PET, Ga-DOMITATE PET/CT, bone scan, or imaging follow-up (>6 months).
RESULTS: From a total of 1008 evaluated patients, 763 (73.02%) were hemato-oncologic patients. A total of 104 rib lesions were found by transversal CT image reading, whereas the unfolded rib image reading detected 305 lesions. Eighty-nine were classified malignant, and 202 were classified benign. Detection of malignant rib lesions proved significant both for less than 1 cm (P < 0.02) and more than 1 cm in diameter (P < 0.007). The sensitivity, specificity, positive predictive value, and negative predictive value for detection of malignant rib lesions were 97.7%, 98.5%, 96.6%, and 99% for unfolding ribs, and 76.4%, 100%, 92.7%, and 90.5% for conventional (transversal) image reading, respectively. Detection of sclerotic rib lesions and lesions greater than 1 cm in diameter were significantly better (P < 0.01) for the unfolding rib algorithm.
CONCLUSIONS: The "unfolded rib" reformates are significantly superior for rib lesion detection compared with conventional transversal CT scan reading and should therefore be used in all patients, particularly those with an oncologic background.
引用
- Ekert K, Kloth C, Fritz J, et al. Improved Detection of Benign and Malignant Rib Lesions in the Routine Computed Tomography Workup of Oncological Patients Using Automated Unfolded Rib Image Postprocessing. Invest Radiol. 2020. PMID: 31498161. doi:10.1097/RLI.0000000000000599
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。