文献速递胸部CT

深度学习算法用于减小CT层厚:对肺癌影像组学特征可重复性的影响

Deep Learning Algorithm for Reducing CT Slice Thickness: Effect on Reproducibility of Radiomic Features in Lung Cancer.
PubMed 文献 · Korean J Radiol · 2019-01-01

该研究回顾性评估CT层厚对肺癌影像组学特征可重复性的影响,并探讨基于卷积神经网络的超分辨率算法能否改善不同层厚图像所得特征的可重复性。结果显示层厚显著影响特征可重复性,超分辨率算法可显著提高可重复性。

要点

  • CT层厚显著影响肺癌影像组学特征的可重复性,1mm与5mm图像间平均CCC仅0.27。
  • 肿瘤强度特征可重复性最好,小波特征最差。
  • 基于CNN的超分辨率算法可显著提高不同层厚图像间特征的可重复性。

核心结论

  • 肺癌影像组学特征的可重复性受CT层厚显著影响,基于CNN的超分辨率算法可改善该可重复性。

研究设计与样本

  • 回顾性评估2017年7月至2017年12月间100例经病理证实的肺癌的1mm、3mm和5mm层厚CT图像。

诊断标准与关键数值

  • 可重复性以一致性相关系数(CCC)≥0.85为达标;原始1mm vs 3mm、1mm vs 5mm、3mm vs 5mm的平均CCC分别为0.41、0.27、0.65(所有比较p<0.001);达到CCC≥0.85的特征比例分别为3.6%、1.0%、21.5%。

临床应用与阅片要点

  • 应用CNN超分辨率算法后,三组配对的平均CCC分别提高至0.58、0.45、0.72(所有比较p<0.001);可重复特征比例分别增至36.3%、17.4%、36.9%。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To retrospectively assess the effect of CT slice thickness on the reproducibility of radiomic features (RFs) of lung cancer, and to investigate whether convolutional neural network (CNN)-based super-resolution (SR) algorithms can improve the reproducibility of RFs obtained from images with different slice thicknesses.

MATERIALS AND METHODS: CT images with 1-, 3-, and 5-mm slice thicknesses obtained from 100 pathologically proven lung cancers between July 2017 and December 2017 were evaluated. CNN-based SR algorithms using residual learning were developed to convert thick-slice images into 1-mm slices. Lung cancers were semi-automatically segmented and a total of 702 RFs (tumor intensity, texture, and wavelet features) were extracted from 1-, 3-, and 5-mm slices, as well as the 1-mm slices generated from the 3- and 5-mm images. The stabilities of the RFs were evaluated using concordance correlation coefficients (CCCs).

RESULTS: The mean CCCs for the comparisons of original 1 mm vs. 3 mm, 1 mm vs. 5 mm, and 3 mm vs. 5 mm images were 0.41, 0.27, and 0.65, respectively (p < 0.001 for all comparisons). Tumor intensity features showed the best reproducibility while wavelets showed the lowest reproducibility. The majority of RFs failed to achieve reproducibility (CCC ≥ 0.85; 3.6%, 1.0%, and 21.5%, respectively). After applying the CNN-based SR algorithms, the reproducibility significantly improved in all three pairings (mean CCCs: 0.58, 0.45, and 0.72; p < 0.001 for all comparisons). The reproducible RFs also increased (36.3%, 17.4%, and 36.9%, respectively).

CONCLUSION: The reproducibility of RFs in lung cancer is significantly influenced by CT slice thickness, which can be improved by the CNN-based SR algorithms.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Park S, Lee SM, Do KH, et al. Deep Learning Algorithm for Reducing CT Slice Thickness: Effect on Reproducibility of Radiomic Features in Lung Cancer. Korean J Radiol. 2019. PMID: 31544368. doi:10.3348/kjr.2019.0212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。