超低剂量CT联合自适应统计迭代重建-V技术检测肺结节的可行性研究
本研究在中国人群中评估超低剂量CT(ULDCT)联合自适应统计迭代重建-V(ASiR-V)检测肺结节的临床价值。188例低剂量CT(LDCT)检出肺结节的患者接受结节中心局部ULDCT扫描,ULDCT有效剂量较LDCT降低89.7%,总结节检出敏感度90.4%,≥6 mm结节敏感度98.2%,结节类型和直径是敏感度的独立预测因素,BMI对检出无影响。
要点
- ULDCT较LDCT辐射剂量降低89.7%,有效剂量0.096±0.006 mSv vs 0.93±0.32 mSv(P<0.001)。
- ULDCT总结节检出敏感度90.4%(170/188),≥6 mm结节敏感度98.2%(54/55)。
- 结节类型和直径是检出敏感度的独立预测因素(P<0.05),BMI无影响(P>0.05)。
核心结论
- 对于BMI≤30 kg/m2的人群,ULDCT可在LDCT约10%的辐射剂量下用于肺结节管理。
研究设计与样本
- 可行性研究,纳入188例BMI 16.41–29.87 kg/m2、LDCT检出肺结节的患者,对所选结节中心行3 cm扫描长度的局部ULDCT;LDCT采用Assist kV(120/100 kV)/Smart mA模式,ULDCT采用120 kV/2.8 mAs,图像以ASiR-V 50%重建;以LDCT所见结节的存在和类型为参考标准。
诊断标准与关键数值
- LDCT共显示188个结节,包括123个实性结节和65个亚实性结节。
- ULDCT总结节检出敏感度90.4%(170/188),≥6 mm结节敏感度98.2%(54/55)。
- 多因素分析显示结节类型和直径是检出敏感度的独立预测因素(P<0.05),患者BMI对结节检出无影响(P>0.05)。
临床应用与阅片要点
- 作者结论认为,对于BMI≤30 kg/m2的人群,ULDCT可在LDCT约10%的辐射剂量下用于肺结节管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the clinical value of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) in the detection of pulmonary nodules in a Chinese population.
METHOD: One hundred eighty-eight patients (16.41 ≤ BMI ≤ 29.87 kg/m2) with pulmonary nodules detected on low-dose chest CT (LDCT) underwent local ULDCT at the center of the chosen nodule with a scan length of 3 cm. LDCT was performed using the Assist kV (120/100 kV)/Smart mA mode and at 120 kV/2.8 mAs for ULDCT. After scanning, CT images were reconstructed with ASiR-V 50%. For both scans, nodule diameters were measured and reference standards were established for the presence and types of lung nodules found on LDCT. The sensitivity of ULDCT was compared against the standard, and logistic regression analysis was used to determine the independent predictors for nodule detection.
RESULTS: Compared with LDCT (0.93 ± 0.32 mSv), a 89.7% dose decrease was seen with ULDCT, for which the calculated effective dose was 0.096 ± 0.006 mSv (P < 0.001). LDCT showed 188 nodules, including 123 solid and 65 subsolid nodules. The overall sensitivity for nodule detection in ULDCT was 90.4% (170/188), and 98.2% (54/55) for nodules ≥ 6 mm. In multivariate analysis, nodule types and diameters were independent predictors of sensitivity (P < 0.05). However, patients' BMI had no effect on nodule detection (P > 0.05).
CONCLUSIONS: ULDCT can be used in the management of pulmonary nodules for people with BMI ≤ 30 kg/m2 at 10% radiation dose of LDCT.
引用
- Ye K, Zhu Q, Li M, et al. A feasibility study of pulmonary nodule detection by ultralow-dose CT with adaptive statistical iterative reconstruction-V technique. Eur J Radiol. 2019. PMID: 31521879. doi:10.1016/j.ejrad.2019.108652
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。