文献速递神经介入DSA

编织式腔内桥接装置治疗后血管造影动脉瘤闭塞的预测因素:单中心中期随访经验

Predicting Factors of Angiographic Aneurysm Occlusion after Treatment with the Woven EndoBridge Device: A Single-Center Experience with Midterm Follow-Up.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-09-19

该单中心研究纳入86例颅内动脉瘤患者,评估编织式腔内桥接装置治疗后中期随访中动脉瘤闭塞和装置形态改变的预测因素。多因素分析显示宽开口(≥4mm)是不完全闭塞的独立因素,规则形态是充分闭塞的独立因素,而不规则形态和宽开口增加装置形态改变概率。装置高度降低在不完全闭塞动脉瘤中更常见,但并非闭塞的独立预后因素。

要点

  • 宽开口(≥4mm)是不完全闭塞的独立预测因素,规则形态是充分闭塞的独立预测因素。
  • 不规则形态和宽开口显著增加编织式腔内桥接装置形态改变的概率。
  • 装置高度降低在不完全闭塞动脉瘤中更常见,但并非闭塞的独立预后因素。

核心结论

  • 宽开口存在时良好闭塞的可能性降低5倍,而规则形态动脉瘤闭塞可能性高6倍。
  • 编织式腔内桥接装置形态改变受动脉瘤形态和开口大小强烈影响,且与血管造影闭塞无独立关联。

研究设计与样本

  • 单中心研究,纳入86例患者/动脉瘤,要求至少12个月血管造影随访。
  • 采用单因素和多因素分析评估充分闭塞(Raymond-Roy 1/Raymond-Roy 2)和编织式腔内桥接装置形态改变(装置高度降低)的独立预测因素。

关键影像表现/征象

  • 动脉瘤平均大小为5.5mm(范围3-11.5mm)。
  • 最常见位置为大脑中动脉(43/86=50%)、基底动脉尖(13/86=15.1%)和前交通动脉(12/86=14%)。
  • 21例患者(21/86=24%)伴有急性蛛网膜下腔出血。
  • 即刻和长期Raymond-Roy 1/Raymond-Roy 2闭塞率分别为49%(42/86)和80%(68/86)。
  • 22%(19/86)的病例检测到编织式腔内桥接装置形态改变。

诊断标准与关键数值

  • 充分闭塞定义为Raymond-Roy 1/Raymond-Roy 2。
  • 宽开口(≥4mm)是不完全闭塞的独立因素(OR=0.2;95%CI,0.01-1;P=.04)。
  • 规则动脉瘤形态是充分闭塞的独立因素(OR=5.9;95%CI,1.4-24;P=.01)。
  • 不规则形态(OR=5.4;95%CI,1.4-19;P=.01)和宽开口(OR=9.8;95%CI,1.6-60;P=.03)显著增加编织式腔内桥接装置形态改变的概率。

临床应用与阅片要点

  • 宽开口(≥4mm)动脉瘤采用编织式腔内桥接装置治疗后不完全闭塞风险较高。
  • 规则形态动脉瘤采用编织式腔内桥接装置治疗后充分闭塞可能性较高。
  • 装置高度降低在不完全闭塞动脉瘤中更常见(6/12=50% versus 13/74=17.5%),但非独立预后因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge is increasingly used for the treatment of intracranial aneurysms. We examined factors leading to aneurysm occlusion and Woven EndoBridge shape change during a midterm follow-up.

MATERIALS AND METHODS: Patients with a minimum 12-month angiographic follow-up were included. Through a univariate and multivariate analysis, independent predictors of adequate occlusion (Raymond-Roy 1/Raymond-Roy 2) and Woven EndoBridge shape change (decrease of the height of the device) were assessed.

RESULTS: Eighty-six patients/aneurysms were included. The aneurysm mean size was 5.5 mm (range, 3-11.5 mm). The most common locations were the MCA (43/86 = 50%), basilar tip (13/86 = 15.1%), and anterior communicating artery (12/86 = 14%). Twenty-one patients (21/86 = 24%) had acute SAH. Immediate and long-term Raymond-Roy 1/Raymond-Roy 2 occlusion rates were 49% (42/86) and 80% (68/86), respectively. Woven EndoBridge shape change was detected among 22% (19/86) of cases. At binary logistic regression, wide ostium (≥4 mm) (OR = 0.2; 95% CI, 0.01-1; P = .04) and regular aneurysm morphology (OR = 5.9; 95% CI, 1.4-24; P = .01) were independent factors of incomplete and adequate aneurysm occlusion, respectively. In addition, irregular morphology (OR = 5.4; 95%CI, 1.4-19; P = .01) and a wide ostium (OR = 9.8; 95% CI, 1.6-60; P = .03) significantly increased the probability of the Woven EndoBridge shape change. Decrease of the Woven EndoBridge height was more common among incompletely occluded aneurysms (6/12 = 50% versus 13/74 = 17.5%), but it was not an independent prognosticator of occlusion at the multivariate model.

CONCLUSIONS: The likelihood of good occlusion was 5 times lower in the presence of a wide ostium, whereas aneurysms with regular morphology were 6 times more likely to be occluded. Woven EndoBridge shape modification was strongly influenced by the aneurysm shape and ostium size, and it was not independently associated with the angiographic occlusion.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Cagnazzo F, Ahmed R, Zannoni R, et al. Predicting Factors of Angiographic Aneurysm Occlusion after Treatment with the Woven EndoBridge Device: A Single-Center Experience with Midterm Follow-Up. AJNR Am J Neuroradiol. 2019. PMID: 31537514. doi:10.3174/ajnr.A6221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。