计算定量MR图像特征——鉴别胶质母细胞瘤与单发脑转移瘤的潜在有用工具
本研究回顾性纳入55例患者(30例胶质母细胞瘤、25例单发脑转移瘤),基于T2W、SWI、CET1图像提取分形与纹理定量参数,评估其鉴别两种肿瘤的能力。结果显示T2W图像的全部5个GLCM参数及CET1图像除相关性外的GLCM参数在两组间有显著差异,纹理特征较分形特征更具鉴别价值,联合多个GLCM参数可提高诊断效能。
要点
- T2W图像的全部5个GLCM纹理参数在胶质母细胞瘤与单发脑转移瘤间均有显著差异。
- CET1图像上除相关性(SCOR)外的GLCM参数在两组间有显著差异。
- 纹理特征较分形特征在鉴别胶质母细胞瘤与单发转移瘤中更具显著性。
核心结论
- 计算辅助定量图像分析可能提高诊断准确性;纹理特征在鉴别胶质母细胞瘤与单发脑转移瘤中较分形特征更具显著性。
研究设计与样本
- 回顾性研究,纳入55例患者(30例胶质母细胞瘤、25例单发脑转移瘤),行T2W/SWI/CET1 MRI,采用盒计数法和灰度共生矩阵(GLCM)法估算分形与纹理分析定量参数。
诊断标准与关键数值
- T2W图像全部5个GLCM参数在胶质母细胞瘤与单发转移瘤间有显著差异;CET1图像除相关性(SCOR)外的GLCM参数有显著差异;SWI图像仅角二阶矩(SASM)和对比度(SCON)两个参数值不同;T2W图像上二值盒维数(Dbin)、归一化盒维数(Dnorm)和空隙度(λ)以及CET1图像上Dnorm共3个分形特征在两组间有显著差异;最高敏感度和特异度分别来自T2W图像的逆差矩(SIDM)和CET1图像的SIDM;联合多个GLCM参数获得更好结果。
临床应用与阅片要点
- T2W图像提供的组间显著差异参数最多,其次为CET1和SWI图像;作者认为计算辅助定量图像分析可能提高诊断准确性,纹理特征较分形特征更具鉴别价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Glioblastomas (GBM) and metastases are the most frequent malignant brain tumors in the adult population. Their presentation on conventional MRI is quite similar, but treatment strategy and prognosis are substantially different. Even with advanced MR techniques, in some cases diagnostic uncertainty remains. The main objective of this study was to determine whether fractal, texture, or both MR image analyses could aid in differentiating glioblastoma from solitary brain metastasis.
METHOD: In a retrospective study of 55 patients (30 glioblastomas and 25 solitary metastases) who underwent T2W/SWI/CET1 MRI, quantitative parameters of fractal and texture analysis were estimated, using box-counting and gray level co-occurrence matrix (GLCM) methods.
RESULTS: All five GLCM parameters obtained from T2W images showed significant difference between glioblastomas and solitary metastases, as well as on CET1 images except correlation (SCOR), contrary to SWI images which showed different values of two parameters (angular second moment-SASM and contrast-SCON). Only three fractal features (binary box dimension-Dbin, normalized box dimension-Dnorm and lacunarity-λ) measured on T2W and Dnorm measured on CET1 images significantly differed GBMs from solitary metastases. The highest sensitivity and specificity were obtained from inverse difference moment (SIDM) on T2W and SIDM on CET1 images, respectively. Combination of several GLCM parameters yielded better results. The processing of T2W images provided the most significantly different parameters between the groups, followed by CET1 and SWI images.
CONCLUSIONS: Computational-aided quantitative image analysis may potentially improve diagnostic accuracy. According to our results texture features are more significant than fractal-based features in differentiation glioblastoma from solitary metastasis.
引用
- Petrujkić K, Milošević N, Rajković N, et al. Computational quantitative MR image features - a potential useful tool in differentiating glioblastoma from solitary brain metastasis. Eur J Radiol. 2019. PMID: 31473463. doi:10.1016/j.ejrad.2019.08.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。