文献速递神经外周血管MRDSA

对比增强磁共振高分辨率可变翻转角快速自旋回波(T1 SPACE)技术在横窦狭窄诊断中的作用

Role of contrast-enhanced magnetic resonance high-resolution variable flip angle turbo-spin-echo (T1 SPACE) technique in diagnosis of transverse sinus stenosis.
PubMed 文献 · Eur J Radiol · 2019-09-10

本研究为前瞻性研究,纳入62例疑似特发性颅内高压且经PC MRV证实横窦狭窄的患者,所有患者均行腰椎穿刺、PC MRV、增强T1 SPACE序列及DSA检查。结果显示增强T1 SPACE在测量狭窄方面与DSA的相关性(AUC=0.953)优于PC MRV(AUC=0.871),且增强T1 SPACE检测到37处窦内充盈缺损,而PC MRV源图像仅检出20处。作者认为增强T1 SPACE序列在评估狭窄和检测病变方面较PC MRV更敏感和特异,可能有助于患者选择和指导治疗。

要点

  • 增强T1 SPACE测量横窦狭窄与DSA的AUC为0.953,优于PC MRV的0.871。
  • 增强T1 SPACE检出37处窦内充盈缺损,PC MRV源图像仅检出20处。
  • 增强T1 SPACE与DSA的加权κ为0.868,PC MRV为0.653。

核心结论

  • 增强T1 SPACE序列在评估横窦狭窄患者的狭窄程度和检测病变方面较PC MRV更敏感和特异。
  • 应用该技术准确判断横窦狭窄的存在和范围可能有助于患者选择和指导治疗。

研究设计与样本

  • 前瞻性研究,纳入2016年11月至2018年10月间62例疑似特发性颅内高压且经PC MRV证实横窦狭窄的患者。
  • 所有患者均行腰椎穿刺、PC MRV、增强T1 SPACE序列及DSA检查,以DSA为标准成像。

关键影像表现/征象

  • 增强T1 SPACE检出37处窦内充盈缺损,而PC MRV源图像仅检出20处。

诊断标准与关键数值

  • 增强T1 SPACE测量狭窄与DSA的AUC为0.953,PC MRV为0.871。
  • 增强T1 SPACE与DSA的Kendall秩相关系数rk=0.895、加权κ=0.868;PC MRV的rk=0.753、加权κ=0.653。

临床应用与阅片要点

  • 作者认为,使用增强T1 SPACE准确判断横窦狭窄的存在和范围可能有助于患者选择和指导治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Transverse sinus stenosis (TSS) is the most sensitive imaging characteristic of idiopathic intracranial hypertension (IIH). This study aimed to assess the diagnostic performance of contrast-enhanced magnetic resonance high-resolution variable flip angle turbo-spin-echo (T1 SPACE) technique in TSS patients and evaluate the diagnostic accuracy of enhanced T1 SPACE, and phase-contrast magnetic resonance venography (PC MRV) with digital subtraction angiography (DSA) as standard imaging.

METHOD: This prospective study enrolled 62 patients with suspected IIH and PC MRV-confirmed transverse sinus stenosis. All patients underwent lumbar puncture, PC MRV, enhanced T1 SPACE sequences and DSA examination. The accuracy, sensitivity, and specificity of enhanced T1 SPACE in detecting venous sinus stenosis were calculated and compared with those of PC MRV. Intermodality agreement (Kendall's rank correlation coefficients and weighted kappa statistic) was assessed.

RESULTS: Sixty-two patients were enrolled from November 2016 to October 2018. For the measured stenosis, better correlation was observed in enhanced T1 SPACE and DSA (AUC = 0.953) than PC MRV (AUC = 0.871). Intermodality agreement of enhanced T1 SPACE (rk = 0.895 and weighted ĸ = 0.868) was better than PC MRV (rk = 0.753 and weighted ĸ = 0.653) compared with DSA. Thirty-seven intrasinus filling defects were detected by contrast-enhanced T1 SPACE, while only twenty of them were detected on source imaging of PC MRV.

CONCLUSIONS: The contrast-enhanced T1 SPACE sequence was more sensitive and specific compared with PC MRV in assessing stenosis and detecting lesions in TSS patients. Accurate determination of the presence and extent of TSS using this technique might be useful in patient selection and guiding the treatment.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Quan T, Ren Y, Lin Y, et al. Role of contrast-enhanced magnetic resonance high-resolution variable flip angle turbo-spin-echo (T1 SPACE) technique in diagnosis of transverse sinus stenosis. Eur J Radiol. 2019. PMID: 31539793. doi:10.1016/j.ejrad.2019.108644

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。