文献速递胸部神经US

M型超声与透视测量获得性脑损伤患者膈肌活动度的比较

Comparison Between M-Mode Ultrasonography and Fluoroscopy for Diaphragm Excursion Measurement in Patients With Acquired Brain Injury.
PubMed 文献 · J Ultrasound Med · 2019-09-12

该前瞻性研究纳入50例获得性脑损伤患者,于入院时分别用M型超声和透视测量膈肌活动度,并与肺功能检查结果进行相关性分析。校正年龄、性别、身高和体重后,右侧相关系数为0.744(P < .001),左侧为0.631(P < .001);偏瘫亚组中瘫痪侧为0.507(P = .007),非瘫痪侧为0.677(P < .001)。非瘫痪侧膈肌活动度与最大吸气压、最大呼气压和峰值咳嗽流量显著相关(P < .05)。作者认为M型超声可作为获得性脑损伤后运动功能受损患者测量膈肌活动度的替代方法。

要点

  • M型超声与透视测量膈肌活动度在获得性脑损伤患者中呈中度至高度相关(右侧0.744,左侧0.631)。
  • 偏瘫患者中非瘫痪侧膈肌活动度与最大吸气压、最大呼气压及峰值咳嗽流量显著相关(P < .05)。
  • 作者认为M型超声可作为运动功能受损的获得性脑损伤患者测量膈肌活动度的替代方法。

核心结论

  • M型超声可作为获得性脑损伤后运动功能受损患者测量膈肌活动度的替代方法,非瘫痪侧膈肌功能保留可能影响脑损伤后的肺功能,提示卒中前呼吸功能的重要性。

研究设计与样本

  • 前瞻性研究,2017年9月至2018年4月纳入50例获得性脑损伤患者,入院时行肺功能检查、M型超声和透视测量膈肌活动度,采用偏相关分析评估超声与透视的相关性。

诊断标准与关键数值

  • 校正年龄、性别、身高和体重后,超声与透视测量膈肌活动度的相关系数右侧为0.744(P < .001),左侧为0.631(P < .001)。
  • 偏瘫患者亚组中,超声与透视的相关系数瘫痪侧为0.507(P = .007),非瘫痪侧为0.677(P < .001)。
  • 非瘫痪侧膈肌活动度与最大吸气压、最大呼气压和峰值咳嗽流量显著相关(P < .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Patients with acquired brain injury show decreased pulmonary function and diaphragm excursion (DE), which can affect functional outcomes. This study aimed to compare ultrasonography (US) and fluoroscopy for DE assessment and to determine how the relationship between pulmonary function test results and DE differs according to the paralytic condition.

METHODS: From September 2017 to April 2018, we prospectively enrolled patients with acquired brain injury. The patients underwent a pulmonary function test, including the functional vital capacity, forced expiratory volume at 1 second, forced expiratory volume at 1 second-to-functional vital capacity ratio, peak cough flow, and respiratory muscle strength such as the maximal inspiratory pressure and maximal expiratory pressure. Diaphragm excursion was measured with M-mode US and fluoroscopy on admission. A partial correlation analysis was used to assess the correlation between US and fluoroscopy for DE assessment.

RESULTS: During the study period, 50 patients with acquired brain injury were enrolled. After adjusting for age, sex, height, and weight, the correlation coefficients between US and fluoroscopy were 0.744 for the right side (P < .001) and 0.631 for the left side (P < .001). In a subgroup analysis for patients with hemiplegia, the correlation coefficients were 0.507 for the paretic side (P = .007) and 0.677 for the nonparetic side (P < .001). Diaphragm excursion in the nonparetic side was significantly correlated with the maximal inspiratory pressure, maximal expiratory pressure, and peak cough flow (P < .05).

CONCLUSIONS: M-mode US can be an alternative method for DE measurement in patients with impaired locomotion function after acquired brain injury. Preserved function of the nonparetic side might affect pulmonary function after brain injury, which suggests the importance of prestroke respiratory function.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Yoon SY, Moon HI, Kim JS, et al. Comparison Between M-Mode Ultrasonography and Fluoroscopy for Diaphragm Excursion Measurement in Patients With Acquired Brain Injury. J Ultrasound Med. 2019. PMID: 31512782. doi:10.1002/jum.15130

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。