PACS整合半自动影像软件可改善多发性硬化日常疾病活动检测
该研究将半自动容积FLAIR对比软件VisTarsier整合入PACS日常流程,对906对MS脑MRI检查对进行比较。软件辅助组20%报告新病灶,常规对比组9%,软件使用与检出新发或增大病灶的OR为4.15(P=.040),86.9%的受访放射科医生认为每份报告可节省至少2-5分钟。
要点
- 软件辅助阅片时20%的检查对报告新病灶,仅常规对比时为9%。
- 软件使用与检出新发或增大病灶相关,OR为4.15(P=.040)。
- 86.9%的问卷受访者认为软件每份报告至少节省2-5分钟。
核心结论
- VisTarsier可在真实临床环境中实施,接受度良好,并保持了回顾性环境中显示的准确性。
研究设计与样本
- 研究纳入2年内538例患者的906对检查,软件辅助组841对、仅常规对比组65对,以广义线性混合模型比较新病灶报告数,并向参与放射科医生发放问卷。
关键影像表现/征象
- 软件为每份含容积FLAIR序列的新发MS脑MRI检查生成额外的配准图像系列,提供彩色编码的疾病活动变化图。
- 软件辅助的检查中20%报告有新病灶,仅常规对比的检查中为9%。
诊断标准与关键数值
- 软件使用与检出新发或增大病灶的OR为4.15(P=.040)。
- 软件辅助组841对检查中20%报告新病灶,仅常规对比组65对检查中9%报告新病灶。
- 86.9%的问卷受访者认为软件每份扫描报告至少节省2-5分钟。
临床应用与阅片要点
- 可将半自动容积FLAIR对比软件整合入PACS日常流程,用于MS脑MRI的疾病活动检测。
- 软件自动生成彩色编码变化图作为额外配准图像系列供报告参考。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The standard for evaluating interval radiologic activity in MS, side-by-side MR imaging comparison, is restricted by its time-consuming nature and limited sensitivity. VisTarsier, a semiautomated software for comparing volumetric FLAIR sequences, has shown better disease-activity detection than conventional comparison in retrospective studies. Our objective was to determine whether implementing this software in day-to-day practice would show similar efficacy.
MATERIALS AND METHODS: VisTarsier created an additional coregistered image series for reporting a color-coded disease-activity change map for every new MS MR imaging brain study that contained volumetric FLAIR sequences. All other MS studies, including those generated during software-maintenance periods, were interpreted with side-by-side comparison only. The number of new lesions reported with software assistance was compared with those observed with traditional assessment in a generalized linear mixed model. Questionnaires were sent to participating radiologists to evaluate the perceived day-to-day impact of the software.
RESULTS: Nine hundred six study pairs from 538 patients during 2 years were included. The semiautomated software was used in 841 study pairs, while the remaining 65 used conventional comparison only. Twenty percent of software-aided studies reported having new lesions versus 9% with standard comparison only. The use of this software was associated with an odds ratio of 4.15 for detection of new or enlarging lesions (P = .040), and 86.9% of respondents from the survey found that the software saved at least 2-5 minutes per scan report.
CONCLUSIONS: VisTarsier can be implemented in real-world clinical settings with good acceptance and preservation of accuracy demonstrated in a retrospective environment.
引用
- Dahan A, Pereira R, Malpas CB, et al. PACS Integration of Semiautomated Imaging Software Improves Day-to-Day MS Disease Activity Detection. AJNR Am J Neuroradiol. 2019. PMID: 31515214. doi:10.3174/ajnr.A6195
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。