指南与共识骨肌CTDR

二维与三维CT对pilon骨折分型及治疗建议的观察者内与观察者间可靠性的影响

Impact of two- and three-dimensional computed tomography use on intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendation.
指南 / 共识 · Orthop Traumatol Surg Res · 2019-09-18

研究纳入10名骨科专家和10名住院医师,使用25例pilon骨折影像,分别在X线片、加入二维CT及加入三维CT时按Rüedi-Allgöwer和AO/OTA分型并选择治疗方案。结果显示二维CT较X线片显著提高分型可靠性,三维CT较二维CT未显著提高;治疗建议的总体观察者间可靠性各影像方式间无显著差异,但住院医师的观察者间一致性从X线片的轻微一致提高到二维CT的中等一致。

要点

  • 二维CT较X线片显著提高pilon骨折分型的观察者内和观察者间可靠性,住院医师改善更明显。
  • 在二维CT基础上加做三维CT,未显著提高分型及治疗建议的观察者内与观察者间可靠性。
  • 治疗建议的总体观察者间可靠性在不同影像方式间无显著差异。

核心结论

  • 使用三维CT与二维CT相比,pilon骨折分型及治疗建议的观察者内和观察者间可靠性未提高。
  • 二维CT图像提高了专家分型的观察者内和观察者间可靠性,以及住院医师分型与治疗建议的观察者间可靠性。

研究设计与样本

  • 病例对照研究,证据等级IV。
  • 10名骨科专家和10名住院医师,使用25例pilon骨折影像完成分型与治疗选择调查。
  • 调查先使用X线片,3周后加入二维CT,6周后加入三维CT。
  • 按Rüedi-Allgöwer和AO/OTA分型,计算Kappa系数评估可靠性。

诊断标准与关键数值

  • 以Kappa系数评估观察者内与观察者间可靠性。
  • 专家分型的观察者内可靠性在使用二维CT较仅用X线片时显著提高。
  • 加用三维CT较二维CT未显著提高观察者内可靠性。
  • 二维CT显著提高两种分型的总体观察者间一致性,住院医师改善幅度更大。
  • 三维CT未提高两种分型的观察者间可靠性。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) have been increasingly used in various intra-articular fractures including pilon fracture. However, no study has investigated intraobserver and interobserver reliabilities of pilon fracture classification using 3D CT images.

HYPOTHESIS: (1) Intraobserver and interobserver agreements of fracture classifications and treatment recommendations will improve by using 2D CT images compared to using plain radiographs only; (2) agreements will improve by adding 3D CT images compared to adding 2D CT images; and (3) agreements of orthopedic residents rather than specialists will be influenced more by imaging modality.

MATERIALS AND METHODS: Ten orthopedic specialists and 10 residents completed a survey to classify the fractures according to the Rüedi-Allgöwer and AO/OTA classifications and to select treatment options using 25 pilon fracture images. The survey was conducted using plain radiographs, with 2D and 3D CT images introduced 3 and 6weeks later, respectively. Kappa coefficients were calculated to determine reliabilities.

RESULTS: Intraobserver reliabilities for fracture classifications in specialists significantly improved by using 2D images compared to using plain radiographs only. Addition of 3D CT did not significantly improve intraobserver reliabilities compared to those with 2D CT. Use of 2D CT images significantly improved overall interobserver agreement of both classifications, with the improvement being greater for residents. Use of 3D CT images did not improve the interobserver reliability of both classifications. Overall interobserver reliabilities for treatment recommendations did not significantly differ according to the imaging modality. However, interobserver agreement among residents significantly improved from slight agreement using radiographs only to fair agreement using 2D CT images.

DISCUSSION: Intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendations did not improve between using 3D and 2D CT. Using 2D CT images improved the intraobserver and interobserver reliabilities of the fracture classifications in specialists and the interobserver reliabilities of the fracture classifications and the treatment recommendations in residents.

LEVEL OF EVIDENCE: IV, case control study.

来源:Orthop Traumatol Surg Res,查看原文。版权归原作者所有。

引用

  1. Byun SE, Choi W, Choi Y, et al. Impact of two- and three-dimensional computed tomography use on intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendation. Orthop Traumatol Surg Res. 2019. PMID: 31542310. doi:10.1016/j.otsr.2019.07.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。