文献速递神经头颈外周血管MRUS

同时非增强血管成像与斑块内出血(SNAP)序列用于颈部动脉夹层的影像评估

Simultaneous non-contrast angiography and intraplaque haemorrhage (SNAP) imaging for cervical artery dissections.
PubMed 文献 · Clin Radiol · 2019-08-12

本研究纳入53例疑似颈部动脉夹层(CeAD)患者,评估SNAP序列(单次扫描同时获得非增强MRA与重T1加权血管壁图像)诊断CeAD的效能,并与常规序列及颈部血管超声对比。SNAP诊断敏感度72.2%、特异度98.2%,与常规序列一致性良好(κ=0.76),与超声一致性极好(κ=0.83),且对壁内血肿的信噪比高于T1W-BB、T2W-BB及PD-VISTA序列(p<0.05)。

要点

  • SNAP单次扫描可同时获得非增强MRA和重T1加权血管壁图像,诊断CeAD敏感度72.2%、特异度98.2%。
  • SNAP与常规序列诊断一致性良好(κ=0.76),与颈部血管超声一致性极好(κ=0.83)。
  • SNAP显示壁内血肿的信噪比高于T1W-BB、T2W-BB和PD-VISTA序列(p<0.05)。

核心结论

  • SNAP序列在诊断CeAD中表现良好,且对壁内血肿的信噪比优于常规T1W-BB等序列,作者认为其有潜力成为高度怀疑CeAD患者筛查及治疗后壁内血肿随访的优先选择。

研究设计与样本

  • 纳入53例疑似CeAD患者,均行SNAP序列(单次扫描同时获得非增强MRA与重T1加权血管壁图像)、常规MRI序列(3D时间飞跃法MRA和T1加权黑血成像)及颈部血管超声检查,分析SNAP诊断CeAD的敏感度、特异度及其与常规序列和超声的一致性,并在随访中比较SNAP与T1W-BB血管壁图像上壁内血肿的绝对信号和信号指数。

关键影像表现/征象

  • SNAP序列可同时显示非增强血管成像与重T1加权血管壁图像,用于识别颈部动脉夹层。
  • 随访中SNAP与T1W-BB血管壁图像上壁内血肿的绝对信号和信号指数无显著差异。
  • SNAP序列显示壁内血肿的信噪比高于T1W-BB、T2W-BB和PD-VISTA序列(p<0.05)。

诊断标准与关键数值

  • SNAP序列诊断CeAD的敏感度为72.2%,特异度为98.2%。
  • SNAP与常规序列诊断CeAD的一致性为Cohen's κ=0.76(p<0.05)。
  • SNAP与颈部血管超声诊断CeAD的一致性为Cohen's κ=0.83(p<0.05)。

临床应用与阅片要点

  • 作者认为SNAP序列有潜力成为高度怀疑CeAD患者筛查的优先选择。
  • 作者认为SNAP序列有潜力用于治疗后壁内血肿的随访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the feasibility of high-resolution magnetic resonance imaging (MRI) with a simultaneous non-contrast angiography and intraplaque haemorrhage (SNAP) sequence in identifying cervical artery dissections (CeAD).

MATERIALS AND METHODS: Fifty-three patients with suspected CeAD underwent the SNAP sequence (including non-contrast magnetic resonance angiography [MRA] and heavy T1-weighting vessel wall images simultaneously in a single scan) and conventional MRI sequences (including three-dimensional [3D] time-of-flight MRA and T1-weighted black-blood imaging [T1W BB]) and cervical vascular ultrasound (CVUS). In diagnosis of CeAD, the diagnostic sensitivity and specificity of SNAP, and the diagnostic coherence between SNAP and conventional sequences and between SNAP and CVUS was analysed. At follow-up, the absolute signal (AS) and signal index (SI) of the intramural haematoma (IMH) between vessel wall images on SNAP and T1W-BB images were compared. The image quality of SNAP was analysed by comparing the signal-to-noise ratio (SNR) between vessel wall images from the SNAP and T1W-BB sequences.

RESULTS: The SNAP sequence was found to provide good performance in the diagnosis of CeAD (sensitivity 72.2%, specificity 98.2%); good agreement was found between SNAP and conventional sequences (Cohen's κ=0.76, p<0.05); and excellent agreement was found between SNAP and CVUS (Cohen's κ=0.83, p<0.05). There was no significant difference between AS or SI of the IMH of the vessel wall images within the SNAP and T1W-BB sequences during the review. The SNAP sequence had higher SNR of the IMH compared to T1W-BB, T2W-BB, proton-density-weighted volume isotropic turbo-spin-echo acquisition imaging (PD-VISTA) sequences (p<0.05).

CONCLUSION: The SNAP sequence holds the potential to be preferred choice for screening of patients with a high suspicion of CeAD and for the follow-up of IMH after treatment.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Huang RJ, Lu Y, Zhu M, et al. Simultaneous non-contrast angiography and intraplaque haemorrhage (SNAP) imaging for cervical artery dissections. Clin Radiol. 2019. PMID: 31416601. doi:10.1016/j.crad.2019.06.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。