文献速递外周血管技术与安全US

使用微泡空化增强外周动脉疾病患者的组织灌注

Augmentation of Tissue Perfusion in Patients With Peripheral Artery Disease Using Microbubble Cavitation.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-08-14

该研究在小鼠中优化超声空化参数后,首次在健康志愿者和外周动脉疾病患者中验证对比超声能否增加下肢灌注。优化条件下联合静脉微泡对比剂使小腿肌肉血流量增加超过2倍,而单纯超声无效,提示可能成为外周动脉疾病的治疗方法。

要点

  • 临床扫描仪经编程优化声学条件后,超声联合微泡对比剂可使健康人和外周动脉疾病患者小腿肌肉血流量增加超过2倍。
  • 单纯超声无此效果,血流增加依赖于静脉微泡对比剂与优化声学环境的联合应用。
  • 小鼠中高线密度和长脉冲持续时间在空化区释放ATP最多,血流 consistently 增加3至4倍。

核心结论

  • 使用优化声学环境的微泡超声可增加肢体骨骼肌灌注,提示可能成为外周动脉疾病的治疗方法。

研究设计与样本

  • 临床前小鼠实验优化声学参数后,在健康志愿者和外周动脉疾病患者中进行的首次人体研究(注册号NCT03195556),评估小腿超声单独或联合静脉微泡对比剂输注10分钟的效果。

诊断标准与关键数值

  • 小鼠中所有声学条件下超声暴露肢体血流均增加;仅最低线密度时,长脉冲(40周期)较小脉冲(5周期)灌注呈阶梯式增加;较高线密度时,无论脉冲持续时间,超声暴露肢体血流 consistently 增加3至4倍。
  • 高线密度和长脉冲持续时间在空化区释放ATP最多。
  • 人体中优化条件联合静脉对比剂使健康受试者和外周动脉疾病患者小腿肌肉血流量均增加超过2倍,而单纯超声无效果。

临床应用与阅片要点

  • 作者认为,使用优化声学环境的微泡超声可增加肢体骨骼肌灌注,提出了治疗外周动脉疾病患者的可能性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The authors investigated ideal acoustic conditions on a clinical scanner custom-programmed for ultrasound (US) cavitation-mediated flow augmentation in preclinical models. We then applied these conditions in a first-in-human study to test the hypothesis that contrast US can increase limb perfusion in normal subjects and patients with peripheral artery disease (PAD).

BACKGROUND: US-induced cavitation of microbubble contrast agents augments tissue perfusion by convective shear and secondary purinergic signaling that mediates release of endogenous vasodilators.

METHODS: In mice, unilateral exposure of the proximal hindlimb to therapeutic US (1.3 MHz, mechanical index 1.3) was performed for 10 min after intravenous injection of lipid microbubbles. US varied according to line density (17, 37, 65 lines) and pulse duration. Microvascular perfusion was evaluated by US perfusion imaging, and in vivo adenosine triphosphate (ATP) release was assessed using in vivo optical imaging. Optimal parameters were then used in healthy volunteers and patients with PAD where calf US alone or in combination with intravenous microbubble contrast infusion was performed for 10 min.

RESULTS: In mice, flow was augmented in the US-exposed limb for all acoustic conditions. Only at the lowest line density was there a stepwise increase in perfusion for longer (40-cycle) versus shorter (5-cycle) pulse duration. For higher line densities, blood flow consistently increased by 3-fold to 4-fold in the US-exposed limb irrespective of pulse duration. High line density and long pulse duration resulted in the greatest release of ATP in the cavitation zone. Application of these optimized conditions in humans together with intravenous contrast increased calf muscle blood flow by >2-fold in both healthy subjects and patients with PAD, whereas US alone had no effect.

CONCLUSIONS: US of microbubbles when using optimized acoustic environments can increase perfusion in limb skeletal muscle, raising the possibility of a therapy for patients with PAD. (Augmentation of Limb Perfusion With Contrast Ultrasound; NCT03195556).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Mason OR, Davidson BP, Sheeran P, et al. Augmentation of Tissue Perfusion in Patients With Peripheral Artery Disease Using Microbubble Cavitation. JACC Cardiovasc Imaging. 2019. PMID: 31422129. doi:10.1016/j.jcmg.2019.06.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。