文献速递外周血管心血管US

利用二维超声向量血流成像优化三维无散度流场重建

Optimization of 3-D Divergence-Free Flow Field Reconstruction Using 2-D Ultrasound Vector Flow Imaging.
PubMed 文献 · Ultrasound Med Biol · 2019-08-02

本研究优化了基于一维阵列探头的高帧率超声粒子成像测速(UIV)获取二维速度、再重建三维无散度流场的插值算法,通过优化无散度基减少边界Runge现象并以广义最小残差法加速求解。在解析Womersley流、稳态螺旋流、直管体模与颈动脉分叉体模四例中,速度场平均相对误差分别为0.82%、4.8%、6.01%和12.8%,较前方法精度提升15%–75%、重建速度加速53–874倍。

要点

  • 一维阵列探头结合HFR UIV多平面二维速度可重建三维无散度流场。
  • 四例测试速度场平均相对误差0.82%–12.8%,精度较前方法提升15%–75%。
  • 重建速度较前方法加速53–874倍。

核心结论

  • 所提方法为使用一维阵列探头在动脉中重建三维血流提供了一种有效且快速的方法。

研究设计与样本

  • 方法学研究,使用解析非稳态Womersley流解与计算流体动力学稳态螺旋流解的粗二维子采样,以及直管体模和颈动脉分叉体模的HFR UIV多平面二维速度场,与计算流体动力学流场对比。

关键影像表现/征象

  • 解析非稳态Womersley流解经粗二维子采样重建全流场,速度场平均相对误差0.82%。
  • 计算流体动力学稳态螺旋流解经粗二维子采样重建全流场,速度场平均相对误差4.8%。
  • 直管体模经HFR UIV多平面二维速度场重建三维流场,与计算流体动力学相比速度场平均相对误差6.01%。
  • 颈动脉分叉体模经HFR UIV多平面二维速度场重建三维流场,与计算流体动力学相比速度场平均相对误差12.8%。

临床应用与阅片要点

  • 作者认为该方法为使用一维阵列探头在动脉中重建三维血流提供了有效且快速的方法。
  • 优化无散度基以减少域边界附近的Runge现象,并在特定条件下用广义最小残差算法求解以缩短求解时间。

局限性

  • 原文在结论中未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

3-D blood vector flow imaging is of great value in understanding and detecting cardiovascular diseases. Currently, 3-D ultrasound vector flow imaging requires 2-D matrix probes, which are expensive and suffer from suboptimal image quality. Our recent study proposed an interpolation algorithm to obtain a divergence-free reconstruction of the 3-D flow field from 2-D velocities obtained by high-frame-rate ultrasound particle imaging velocimetry (High Frame Rate echo-Particle Imaging Velocimetry, also known as HFR Ultrasound Imaging Velocimetry (UIV)), using a 1-D array transducer. The aim of this work was to significantly improve the accuracy and reduce the time-to-solution of our previous approach, thereby paving the way for clinical translation. More specifically, accuracy was improved by optimising the divergence-free basis to reduce Runge phenomena near domain boundaries, and time-to-solution was reduced by demonstrating that under certain conditions, the resulting system could be solved using widely available and highly optimised generalised minimum residual algorithms. To initially illustrate the utility of the approach, coarse 2-D subsamplings of an analytical unsteady Womersely flow solution and a steady helical flow solution obtained using computational fluid dynamics were used successfully to reconstruct full flow solutions, with 0.82% and 4.8% average relative errors in the velocity field, respectively. Subsequently, multiplane 2-D velocity fields were obtained through HFR UIV for a straight-tube phantom and a carotid bifurcation phantom, from which full 3-D flow fields were reconstructed. These were then compared with flow fields obtained via computational fluid dynamics in each of the two configurations, and average relative errors of 6.01% and 12.8% in the velocity field were obtained. These results reflect 15%-75% improvements in accuracy and 53- to 874-fold acceleration of reconstruction speeds for the four cases, compared with the previous divergence-free flow reconstruction method. In conclusion, the proposed method provides an effective and fast method to reconstruct 3-D flow in arteries using a 1-D array transducer.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhou X, Vincent P, Zhou X, et al. Optimization of 3-D Divergence-Free Flow Field Reconstruction Using 2-D Ultrasound Vector Flow Imaging. Ultrasound Med Biol. 2019. PMID: 31378550. doi:10.1016/j.ultrasmedbio.2019.06.402

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。