文献速递骨肌US

髌下切面:测量股骨远端软骨厚度的超声新技术

The Transverse Infrapatellar View: A New Ultrasound Technique to Measure Distal Femoral Cartilage Thickness.
PubMed 文献 · J Ultrasound Med · 2019-08-26

研究在19名无症状年轻人和70例疼痛性膝骨关节炎患者中,比较伸膝位髌下切面与屈膝位髌上切面超声测量股骨远端软骨厚度的可靠性和表面效度。髌下切面组间ICC为0.856-0.858,高于髌上切面的0.315-0.523;髌下切面在髁间窝和外侧髁处能显著区分对照组与膝骨关节炎组。结论认为髌下超声评估股骨远端软骨厚度可作为髌上评估的可靠替代方法。

要点

  • 伸膝位髌下切面测量股骨远端软骨厚度的组间ICC为0.856-0.858,高于屈膝位髌上切面的0.315-0.523。
  • 髌下切面在髁间窝(P < .001)和外侧髁(P = .006)处能显著区分对照组与膝骨关节炎组。
  • 髌上切面仅在能外侧髁区域显著区分对照组与膝骨关节炎组(P = .014)。

核心结论

  • 髌下超声评估股骨远端软骨厚度可作为髌上超声评估膝骨关节炎患者的可靠替代方法。

研究设计与样本

  • 在19名年轻无症状成人(对照组)和70例疼痛性膝骨关节炎患者中比较髌下切面与髌上切面超声测量股骨远端软骨厚度的可靠性研究;髌下切面于伸膝位将探头置于髌腱上、向股骨远端髁倾斜60°获得。

关键影像表现/征象

  • 髌下切面在伸膝位将探头置于髌腱上并向股骨远端髁倾斜60°获取图像。
  • 软骨厚度在股骨内侧髁、髁间窝和股骨外侧髁三个位置测量。
  • 症状性膝骨关节炎患者中,髌下切面测量的组间ICC为0.856-0.858,髌上切面为0.315-0.523。

诊断标准与关键数值

  • 髌下切面软骨厚度在髁间窝处对照组与膝骨关节炎组差异显著(P < .001),在外侧髁处差异显著(P = .006)。
  • 髌上切面软骨厚度仅在股骨外侧髁区域对照组与膝骨关节炎组差异显著(P = .014)。
  • 组间ICC:髌下切面0.856-0.858,髌上切面0.315-0.523(症状性膝骨关节炎患者)。

临床应用与阅片要点

  • 伸膝位髌下切面可作为膝骨关节炎患者测量股骨远端软骨厚度的可靠替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine the reliability and face validity of ultrasound (US) measurements of distal femoral cartilage thickness (CT) using the infrapatellar view (IPV) with knee extension compared to the traditional suprapatellar view (SPV) with knee hyperflexion in young asymptomatic participants and patients with painful knee osteoarthritis (KOA).

METHODS: The IPV was obtained in an extended knee position by placing the US transducer on the patellar tendon at a 60° angle tilted toward the distal femoral condyle in 19 young adults (control group) and 70 patients with KOA. The CT was measured at the medial femoral condyle, the intercondylar notch, and the lateral femoral condyle.

RESULTS: The inter-rater intraclass correlation coefficient was higher for IPV-based CT measurement (range, 0.856-0.858) compared to SPV-based CT measurement (range, 0.315-0.523) among the patients with symptomatic KOA. The IPV-based CT differed significantly between the control group and the KOA group at the intercondylar notch (P < .001) and lateral femoral condyle (P = .006). The SPV-based CT differed significantly between the control group and the KOA group only at the lateral femoral condyle region (P = .014).

CONCLUSIONS: An infrapatellar US evaluation of the distal femoral CT can be a reliable alternative method to a suprapatellar US evaluation for patients with KOA.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lee SW, Patel J, Van Dien C, et al. The Transverse Infrapatellar View: A New Ultrasound Technique to Measure Distal Femoral Cartilage Thickness. J Ultrasound Med. 2019. PMID: 31452247. doi:10.1002/jum.15122

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。