文献速递骨肌MR

胫骨骨应力性损伤:简化5分钟磁共振方案的诊断性能与阅片者间一致性

Tibial bone stress injury: diagnostic performance and inter-reader agreement of an abbreviated 5-min magnetic resonance protocol.
PubMed 文献 · Skeletal Radiol · 2019-08-17

这项回顾性研究纳入88例疑似胫骨骨应力性损伤患者的95次MR检查,由3名肌骨放射科医生分别用仅含轴位脂肪抑制T2加权图像的简化方案(5分钟)和完整方案(25分钟)独立分级。结果显示两种方案在分级准确率和阅片者间一致性上均无显著差异,简化方案完整检查的汇总准确率分别为47.8%和50.2%,Kendall一致性系数分别为0.805和0.767。

要点

  • 简化5分钟MR方案(仅轴位脂肪抑制T2WI)与完整25分钟方案对胫骨骨应力性损伤的分级准确率无显著差异。
  • 完整方案与简化方案的汇总完全准确率分别为47.8%和50.2%,1级内准确率分别为82.8%和82.0%。
  • 两种方案的阅片者间一致性均达到「相当一致」水平,Kendall系数分别为0.805和0.767。

核心结论

  • 简化5分钟MR方案与完整25分钟方案在评估疑似胫骨骨应力性损伤时,分级准确率和阅片者间一致性均无显著差异。

研究设计与样本

  • IRB批准的回顾性研究,纳入88例疑似胫骨骨应力性损伤患者的95次连续MR检查,由3名肌骨放射科医生独立分级;简化方案仅含轴位脂肪抑制T2加权图像,完整方案为25分钟。

关键影像表现/征象

  • 原文未报告具体影像征象描述。

诊断标准与关键数值

  • 完整方案汇总完全准确率47.8%,1级内准确率82.8%,2级内准确率96.1%,简化方案对应分别为50.2%、82.0%、93.9%。
  • 采用将2、3、4A级合并为一组的「临床相关」简化分类时,完整方案准确率58.6%,简化方案64.2%。
  • 完整方案阅片者间Kendall一致性系数0.805,简化方案0.767,两者无显著差异。

临床应用与阅片要点

  • 原文未据此给出临床推荐。
  • 作者结论为简化方案与完整方案在胫骨骨应力性损伤分级中诊断性能无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance and inter-reader agreement of an abbreviated (5 min) MR protocol compared to a complete (25 min) protocol, for evaluation of suspected tibial bone stress injury.

MATERIALS AND METHODS: This IRB-approved retrospective study consisted of 95 consecutive MR examinations in 88 patients with suspected tibial bone stress injury. Three musculoskeletal radiologists independently classified all examinations utilizing both an abbreviated protocol consisting only of axial T2-weighted images with fat suppression, and after a washout period again classified the complete examinations. Accuracy was calculated as proportion of cases classified exactly, within 1 grade, within 2 grades, and also utilizing a simplified "clinically relevant" classification combining grades 2, 3, and 4A into a single group. Significance testing was performed with the chi-test, and a post-hoc power analysis was performed. Inter-reader agreement was calculated with Kendall's coefficient of concordance, with significance testing performed utilizing the z-test after bootstrapping to obtain the standard error.

RESULTS AND CONCLUSIONS: There was no significant difference in accuracy of grading tibial bone stress injuries between complete and abbreviated examinations. For complete exams, pooled exact accuracy was 47.8%; accuracy within 1 grade was 82.8%; and accuracy within 2 grades was 96.1%. For the abbreviated protocol, corresponding accuracies were 50.2, 82.0, and 93.9%. With the "clinically relevant" simplified classification, accuracy was 58.6% for complete exams and 64.2% for abbreviated exams. There was no significant difference in inter-reader agreement, with substantial agreement demonstrated for both complete (Kendall coefficient of concordance 0.805) and abbreviated examinations (coefficient of 0.767).

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Mann JR, Wieschhoff GG, Tai R, et al. Tibial bone stress injury: diagnostic performance and inter-reader agreement of an abbreviated 5-min magnetic resonance protocol. Skeletal Radiol. 2019. PMID: 31420694. doi:10.1007/s00256-019-03297-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。