文献速递妇产影像腹部MR

磁敏感加权成像用于术前评估盆腔子宫内膜异位症范围的探索性研究

Exploratory study of the interest of MR susceptibility-weighted imaging for the pre-operative assessment of pelvic endometriosis extent.
PubMed 文献 · Eur J Radiol · 2019-06-24

这项前瞻性研究在2017年6月至2018年4月纳入74例子宫内膜异位症诊断或术前评估患者,采用3T MRI在常规序列基础上加做SWAN序列,其中10例接受腹腔镜手术并与MRI结果对照。结果显示81%的病灶在SWAN序列上出现与出血相关的信号丢失,而仅52%的病灶在T1加权序列上呈高信号;

要点

  • SWAN序列上81%的子宫内膜异位症病灶可见与出血相关的信号丢失,高于T1加权高信号病灶的52%。
  • 加做SWAN序列后MRI诊断敏感度94%、特异度73%,常规方案分别为88%和69%。

核心结论

  • SWI可通过检测子宫内膜异位症病灶的出血特征来提高MRI的诊断准确率。

研究设计与样本

  • 前瞻性研究,在子宫内膜异位症诊断或术前评估阶段进行,时间为2017年6月至2018年4月。
  • 共纳入74例患者,其中10例接受腹腔镜手术并与MRI结果对照。
  • 采用3T MRI设备,协议包括T2W、T1W(含和不含脂肪饱和序列),并加做SWI序列T2-star加权血管成像(SWAN)。
  • 由2位读者分别先用常规MR协议、再用补充SWAN序列评估诊断效能和观察者间一致性。

关键影像表现/征象

  • 81%的子宫内膜异位症病灶在SWAN序列上出现与出血特征相关的信号丢失。
  • 仅52%的病灶在T1加权序列上呈高信号植入灶。

诊断标准与关键数值

  • 完整协议(含SWAN序列)诊断敏感度94%、特异度73%。
  • 常规协议诊断敏感度88%、特异度69%。
  • 加做SWAN序列对子宫骶骨韧带、子宫颈后 site 和 torus uterinus 受累的评估尤其有改善。

临床应用与阅片要点

  • 在常规MRI协议中加做SWAN序列有助于检出子宫内膜异位症病灶的出血特征,从而提高诊断效能。
  • SWAN序列对子宫骶骨韧带、子宫颈后 site 和 torus uterinus 受累的评估改善尤为明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance of magnetic resonance imaging (MRI) with susceptibility-weighted imaging (SWI) in the assessment of endometriosis.

MATERIAL AND METHODS: This prospective study was performed during the diagnostic step or the pre-operative assessment of endometriosis, between June 2017 and April 2018. The MRI was conducted with a 3T MRI device; protocol included T2W, T1W, with and without fat-saturation sequences completed with a SWI sequence: T2-star weighted angiography (SWAN). The diagnostic performance values of MRI and inter-observer agreement were first evaluated with a conventional MR protocol and then with the complementary SWAN sequence by 2 readers. MRI results were correlated with surgical findings in patients who underwent laparoscopy.

RESULTS: 74 patients were included in the study, and among them 10 patients were treated by laparoscopy. 81% of the endometriosis lesions had signal losses on the SWAN sequence related to hemorrhagic character whereas only 52% of the lesions had T1-weighted hyperintense implants. Diagnostic performance of the MRI examination was improved by the use of the SWAN sequence compared to the conventional MR protocol (Se = 94% and Spe = 73% in complete protocol and Se = 88% and Spe = 69% in conventional protocol), especially for the involvement of torus uterinus, utero-sacral ligament and retro-cervical site. An excellent interobserver agreement (қ-value = 0,94) was noted between the two readers.

CONCLUSION: SWI can improve the diagnostic accuracy of MRI by allowing the detection of hemorrhagic character of endometriosis lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pin L, Monseau-Thiburce AC, Ziade-Coularis C, et al. Exploratory study of the interest of MR susceptibility-weighted imaging for the pre-operative assessment of pelvic endometriosis extent. Eur J Radiol. 2019. PMID: 31439249. doi:10.1016/j.ejrad.2019.06.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。