增强T2星加权血管成像(ESWAN)在鉴别卵巢交界性与恶性上皮性肿瘤中的价值
本研究纳入34例患者共37个病灶(交界性上皮性卵巢肿瘤14个、恶性上皮性卵巢肿瘤23个),分析ESWAN的幅度图、相位图、R2*图和T2*图。交界性肿瘤的R2*值低于恶性组(P<0.001),T2*值高于恶性组(P=0.01);R2*值的AUC为0.894,优于T2*值的0.776。结论认为R2*和T2*值可用于定量鉴别两者,R2*诊断效能更好。
要点
- 交界性上皮性卵巢肿瘤R2*值低于恶性组(P<0.001),T2*值高于恶性组(P=0.01)。
- R2*值鉴别两者的AUC为0.894,截断值7.50 Hz,敏感度85.7%、特异度82.6%、准确率86.5%。
- T2*值AUC为0.776,截断值143.73 ms,敏感度71.4%、特异度82.6%、准确率78.4%。
核心结论
- R2*和T2*值可定量鉴别交界性与恶性上皮性卵巢肿瘤,R2*诊断效能优于T2*。
研究设计与样本
- 研究纳入34例患者共37个病灶,其中交界性上皮性卵巢肿瘤14个、恶性上皮性卵巢肿瘤23个。
- 由两名观察者分析ESWAN的幅度图、相位图、R2*图和T2*图,感兴趣区沿肿瘤边界绘制于实性面积最大的层面,参照脂肪抑制T2WI和T1WI。
- 采用组内相关系数检验两名观察者三次测量的一致性,Bland-Altman图评估两名观察者平均测量值的一致性。
关键影像表现/征象
- 交界性组与恶性组的幅度值和相位值均无统计学差异。
- 交界性组R2*值低于恶性组(P<0.001),T2*值高于恶性组(P=0.01)。
诊断标准与关键数值
- R2*值鉴别交界性与恶性上皮性卵巢肿瘤的AUC为0.894,截断值7.50 Hz,敏感度85.7%、特异度82.6%、准确率86.5%。
- T2*值鉴别两者的AUC为0.776,截断值143.73 ms,敏感度71.4%、特异度82.6%、准确率78.4%。
临床应用与阅片要点
- 阅片时可测量肿瘤实性区R2*和T2*值,交界性肿瘤倾向R2*较低、T2*较高。
- R2*值诊断效能优于T2*值,可作为定量鉴别的优先指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the potential of ESWAN in differentiating borderline epithelial ovarian tumors (BEOTs) from malignant epithelial ovarian tumors (MEOTs).
METHOD: Thirty-four patients with 37 lesions were enrolled, including 14 BEOTs and 23 MEOTs. The magnitude, phase, R2* and T2* maps were analyzed by two observers. The regions of interest were drawn along the boundaries of tumors on the slice with maximal solid area, according to fat suppression T2WI and T1WI. The consistency among the three measurements taken by two observers was tested by intra-class correlation coefficients. Agreement of average values measured by two observers was evaluated by Bland-Altman plots. All the data of BEOTs and MEOTs were compared using the independent-sample t test. The receiver operating characteristic curve was used to evaluate the diagnostic performance.
RESULTS: No statistical differences were observed in the magnitude and phase values between two tumor groups. The R2* value of BEOTs was lower than that of MEOTs (P < 0.001), whereas the T2* value of BEOTs was higher than that of MEOTs (P = 0.01). The area under the curve of R2* values was 0.894 and the corresponding cutoff value was 7.50 Hz, with the sensitivity, specificity and accuracy of 85.7%, 82.6% and 86.5%, respectively. The AUC of T2* values was 0.776 and the corresponding cutoff value was 143.73 ms with the sensitivity, specificity and accuracy of 71.4%, 82.6% and 78.4%, respectively.
CONCLUSIONS: R2* and T2* values can be used for quantificationally differentiating BEOTs from MEOTs and the R2* has better diagnostic performance.
引用
- Han X, Sun M, Wang M, et al. The enhanced T2 star weighted angiography (ESWAN) value for differentiating borderline from malignant epithelial ovarian tumors. Eur J Radiol. 2019. PMID: 31439240. doi:10.1016/j.ejrad.2019.07.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。