文献速递妇产影像腹部MR

多b值扩散加权成像用于早期子宫内膜癌风险分层的术前评估

Multi-b-value diffusion weighted imaging for preoperative evaluation of risk stratification in early-stage endometrial cancer.
PubMed 文献 · Eur J Radiol · 2019-08-12

本研究纳入53例术前接受13个b值(0~2000s/mm²)多b值DWI的早期子宫内膜癌患者,由两名放射科医师独立测量ADC、D、D*和f值。中危组较低危组ADC和D值显著降低(P=0.000和0.011),高危组较低危组ADC和D值亦显著降低(P=0.001和0.013),f值仅在低危与中危组间有显著差异(P=0.011)。ADC值识别低危早期子宫内膜癌的AUC最高(0.892),ADC联合f值的AUC为0.912、敏感度81.1%、特异度87.5%。

要点

  • 早期子宫内膜癌中危组较低危组ADC和D值显著降低,高危组较低危组亦显著降低。
  • f值仅在低危与中危组间有显著差异(P=0.011)。
  • ADC联合f值鉴别低危早期子宫内膜癌的AUC为0.912(敏感度81.1%、特异度87.5%)。

核心结论

  • 多b值DWI参数为早期子宫内膜癌风险分层评估提供有价值的影像生物标志物,该手段可能有助于选择最佳治疗方式并促进更个性化的肿瘤诊疗。

研究设计与样本

  • 研究纳入53例术前接受多b值DWI(13个b值,0~2000s/mm²)的早期子宫内膜癌患者,由两名放射科医师独立测量ADC、D、D*和f值,采用二元逻辑回归模型计算有统计学意义的联合参数预测概率,并对所有单一及联合参数行ROC分析。

诊断标准与关键数值

  • 中危组较低危组ADC和D值显著降低(P=0.000和0.011),高危组较低危组ADC和D值显著降低(P=0.001和0.013),f值仅在低危与中危组间有显著差异(P=0.011)。单一参数中ADC值识别低危早期子宫内膜癌的AUC最高(AUC=0.892);ADC联合f值诊断效能最佳,AUC=0.912、敏感度81.1%、特异度87.5%。

临床应用与阅片要点

  • 作者认为多b值DWI参数可为早期子宫内膜癌风险分层评估提供有价值的影像生物标志物,可能有助于选择最佳治疗方式并促进更个性化的肿瘤诊疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the application of multi-b-value DWI parameters for the assessment of risk stratification in early-stage endometrial cancer (EC).

MATERIAL AND METHODS: Fifty-three patients with early-stage EC who preoperatively underwent multi-b-value DWI with 13 b values (from 0 to 2000s/mm²) were included in this study. Multi-b-value DWI derived parameters, including apparent diffusion coefficient (ADC), true diffusivity (D), perfusion-related diffusivity (D*) and perfusion fraction (f) were measured independently by two radiologists. In addition, binary logical regression model was used to calculate predicative probability of combined parameters indicating statistical significance in differentiating risk stratification of early-stage endometrial cancer. Receiver operating characteristic analysis was performed for all single and combined parameters.

RESULTS: The ADC and D values were significantly lower in intermedium-risk compared with low-risk (P = 0.000 and 0.011), as well as high-risk compared with low-risk of early-stage EC (P = 0.001 and 0.013), while f values only showed significant differences between low-risk and intermedium-risk groups (P = 0.011). Among the single parameters, the ADC values had the highest area under the ROC curve (AUC) in the identification of the low-risk of early-stage EC (AUC=0.892). Moreover, the combination of ADC and f value had the best diagnostic performance with the AUC of 0.912, the sensitivity of 81.1% and the specificity of 87.5%.

CONCLUSION: The multi-b-value DWI parameters provide valuable imaging biomarkers for the assessment of risk stratification in early-stage endometrial cancer. This approach might facilitate the selection of the optimal therapeutic approach and lead to the greater personalization of cancer care.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang Q, Yu X, Lin M, et al. Multi-b-value diffusion weighted imaging for preoperative evaluation of risk stratification in early-stage endometrial cancer. Eur J Radiol. 2019. PMID: 31446209. doi:10.1016/j.ejrad.2019.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。