弥散峰度成像对前列腺癌的诊断评估:在活检人群中的检测
前瞻性评估弥散峰度成像与标准弥散加权成像相比,在活检人群中区分前列腺癌与良性前列腺增生的可行性,以及区分低级别与高级别恶性区域的能力。147例疑似前列腺癌患者行1.5-T多参数MRI,弥散峰度成像采用5个b值。ADC、D和K能在外周带和移行带区分良恶性组织(P<0.01),但不能区分低级别与高级别病变,也不能区分GS 3+4与GS 4+3;K在外周带和移行带区分前列腺癌与良性前列腺增生的曲线下面积显著大于ADC。
要点
- ADC、D和K在外周带和移行带均可区分前列腺癌与良性前列腺增生(P<0.01)。
- K区分前列腺癌与良性前列腺增生的曲线下面积在外周带和移行带均显著大于ADC。
- ADC、D和K均不能区分低级别(GS 3+3)与高级别(GS≥3+4)病变,也不能区分GS 3+4与GS 4+3。
核心结论
- 弥散峰度模型可能在前列腺癌检测和诊断中增加价值,但不能区分低级别与高级别前列腺癌(包括GS 3+4与GS 4+3)。
研究设计与样本
- 前瞻性研究,纳入147例连续疑似前列腺癌患者,行1.5-T多参数MRI。
- 弥散峰度成像采用5个b值(0、600、800、1600和2400 sec/mm²)。
- 由两名放射科医师在ADC、D和K图上进行感兴趣区(ROI)测量。
- 采用混合模型方差分析和受试者工作特征曲线分析数据;采用Pearson相关系数分析外周带和移行带中三个参数(ADC、D、K)在所有患者中的相关性,以及前列腺癌组中三个参数与肿瘤Gleason评分(GS)的相关性。
诊断标准与关键数值
- 58例患者证实为前列腺癌(9例GS 3+3[外周带/移行带=4/5],49例GS≥7[外周带/移行带=26/23]),89例为良性前列腺增生。
- ADC、D和K在外周带和移行带区分良性与肿瘤组织(P<0.01),但在区分低级别(GS 3+3)与高级别(GS≥3+4)病变以及GS 3+4与GS 4+3方面表现不佳。
- GS与ADC、D呈弱相关(外周带:ADC r=-0.113,D r=-0.139;移行带:ADC r=-0.104,D r=-0.103),GS与K呈中度相关(外周带:K r=0.492;移行带:K r=0.433,P<0.01)。
- K区分前列腺癌与良性前列腺增生的曲线下面积在外周带和移行带均显著大于ADC。
临床应用与阅片要点
- 在外周带和移行带,ADC、D和K均可用于区分前列腺癌与良性前列腺增生。
- K区分前列腺癌与良性前列腺增生的曲线下面积在外周带和移行带均显著大于ADC。
- ADC、D和K均不能区分低级别与高级别前列腺癌,包括GS 3+4与GS 4+3。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To prospectively assess the feasibility of diffusional kurtosis (DK) imaging for distinguishing prostate cancer(PCa) from benign prostate hyperplasia (BPH) in comparison with standard diffusion-weighted (DW) imaging, as well as low-from high-grade malignant regions.
MATERIALS AND METHODS: 147 consecutive patients with suspected PCa underwent multi-parametric 1.5-TMR. Diffusion kurtosis imaging was acquired with with 5 b values (0,600,800,1600,and 2400sec/mm2).Region of interest (ROI)-based measurements were performed on ADC, D, and K map by two radiologists. Data were analyzed by using mixed-model analysis of variance and receiver operating characteristic curves. Correlations among the three parameters (ADC,D and K) in all patients, and correlations between three parameters with the tumor Gleason score (GS) in PCa group were analyzed using Pearson's correlation coefficient in peripheral zone(PZ) and transiton zone(TZ).
RESULTS: 58 patients were proved with PCa (9 GS 3 + 3[PZ/TZ = 4/5], 49 GS ≥ 7 [PZ/TZ = 26/23]), and 89 patients were with BPH. ADC,D and K were able to distinguish benignance from tumor tissue both in PZ and TZ(P<0.01), but performed poorly in neither differentiating low-(GS 3 + 3) from high-grade (GS≥3 + 4) disease, nor GS(3 + 4) from GS(4 + 3).There was a weak correlation between the GS and ADC, D (PZ:ADC r=-0.113, D r=-0.139; TZ:ADC r=-0.104,D r=-0.103), while a moderate correlation between the GS and K(PZ:K r = 0.492; TZ:K r = 0.433, P<0.01).K had significantly greater area under the curve for differentiating PCa from BHP than ADC both in PZ and TZ.
CONCLUSION: DK model may add value in PCa detection and diagnosis, but none can differentiate low-from high-grade PCas (including GS=3+4 from GS=4+3).
引用
- Ding K, Yao Y, Gao Y, et al. Diagnostic evaluation of diffusion kurtosis imaging for prostate cancer: Detection in a biopsy population. Eur J Radiol. 2019. PMID: 31439233. doi:10.1016/j.ejrad.2019.07.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。