CT鱼嘴壶腹征:主胰管型及混合型导管内乳头状黏液性肿瘤的高度特异性征象
本研究回顾性盲法分析44例组织学确诊的导管内乳头状黏液性肿瘤(IPMN)患者与87例年龄匹配的胰管扩张对照,定义CT鱼嘴壶腹征为从胰管连续延伸至十二指肠腔的水样密度柱。该征象见于18.5%的主胰管型/混合型IPMN患者,特异度100%、阳性预测值100%、阴性预测值79.8%,但与高级别异型增生或浸润无显著关联。
要点
- CT鱼嘴壶腹征定义为从胰管连续延伸至十二指肠腔的水样密度柱,是主胰管型/混合型IPMN的高度特异性征象。
- 该征象在主胰管型/混合型IPMN中特异度100%、阳性预测值100%、阴性预测值79.8%,见于18.5%的患者。
- CT鱼嘴壶腹征与高级别异型增生或浸润的存在无显著关联。
核心结论
- CT鱼嘴壶腹征是新报道的主胰管型及混合型IPMN高度特异性征象;若CT上识别出鱼嘴壶腹,主胰管型或混合型IPMN的可能性很高。
研究设计与样本
- 回顾性盲法病例对照研究,纳入44例组织学确诊的IPMN患者与87例年龄匹配的CT胰管扩张对照,并按胰管扩张程度匹配。
关键影像表现/征象
- CT鱼嘴壶腹征表现为从胰管连续延伸至十二指肠腔的水样密度柱。
- 该征象可在18.5%的主胰管型/混合型IPMN患者中识别。
诊断标准与关键数值
- CT鱼嘴壶腹征诊断主胰管型/混合型IPMN:特异度100%、阳性预测值100%、阴性预测值79.8%。
- CT鱼嘴壶腹征与高级别异型增生或浸润无显著关联。
临床应用与阅片要点
- 阅片时若见从胰管连续延伸至十二指肠腔的水样密度柱(CT鱼嘴壶腹征),提示主胰管型或混合型IPMN可能性很高。
- 该征象与高级别异型增生或浸润无显著关联,不能据此判断肿瘤侵袭性或分级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Main duct and mixed intraductal papillary mucinous neoplasms (IPMN) are pre-malignant cystic pancreatic neoplasms associated with pancreatic duct dilatation. Distinguishing these from benign causes of pancreatic duct dilatation is important in order to allow appropriate surveillance or surgery. A patulous duodenal papilla with extrusion of mucus at endoscopic evaluation, the endoscopic fish mouth ampulla (E-FMA) sign, is reported in main duct and mixed IPMN. We aimed to establish whether a CT correlate (CT-FMA) of this sign exists and whether this was associated with the presence of invasion or high-grade dysplasia. We defined the CT-FMA sign as an uninterrupted column of water attenuation material running from the pancreatic duct to the duodenal lumen.
METHODS: A retrospective, blinded review of 44 patients with histologically confirmed IPMN and 87 age-matched controls with pancreatic duct dilatation on CT was undertaken. A case-control series matched for the degree of pancreatic duct dilatation was used to compare the rates of invasion or high-grade dysplasia between main duct and mixed IPMN patients, with and without a CT-FMA sign.
RESULTS: The CT-FMA sign could be identified in 18.5% patients with main duct/mixed IPMN with specificity 100%, positive predictive value 100% and negative predictive value 79.8%. A significant association was found between CT-FMA in main duct/mixed IPMN compared to controls, but not with the presence of high-grade dysplasia or invasion.
CONCLUSIONS: The CT-FMA sign is a newly reported, highly specific sign of MD and mixed IPMN.
ADVANCES IN KNOWLEDGE: If a fish mouth ampulla is identified at CT, a diagnosis of main duct or mixed IPMN is highly likely.
引用
- Zhang TT, Sadler TJ, Whitley S, et al. The CT fish mouth ampulla sign: a highly specific finding in main duct and mixed intraductal papillary mucinous neoplasms. Br J Radiol. 2019. PMID: 31430199. doi:10.1259/bjr.20190461