研究以40只雄性Sprague-Dawley大鼠为对象,通过蛋氨酸-胆碱缺乏饮食诱导不同时长肝脂肪变性,以组织病理学为参考标准,评估超声归一化局部方差(NLV)技术诊断肝脂肪变性的效能。结果显示NLV检测轻、中、重度肝脂肪变性的AUC分别为0.953、0.896、0.735,在检测≥轻度或≥中度肝脂肪变性时与磁共振波谱(MRS)诊断效能相当;多因素线性回归显示肝脂肪变性程度是影响NLV值的唯一显著因素(p < 0.001)。

要点

  • NLV检测轻度肝脂肪变性的AUC为0.953,检测中度者为0.896,检测重度者为0.735。
  • NLV在检测≥轻度或≥中度肝脂肪变性时与MRS诊断效能相当。
  • 肝脂肪变性程度是影响NLV值的唯一显著因素(p < 0.001)。

核心结论

  • 超声NLV值在评估不同程度肝脂肪变性方面表现出令人满意的诊断效能,肝脂肪变性程度是影响NLV值的唯一显著因素。

研究设计与样本

  • 研究纳入40只雄性Sprague-Dawley大鼠,按蛋氨酸-胆碱缺乏饮食喂养不同时长(0、2、4、6、8、10、12天或2、3、4周,每组4只)分组;每段饮食期结束后行MRS和NLV检查,随后处死大鼠行组织病理学评估作为参考标准;采用ROC曲线分析评估NLV检测不同程度肝脂肪变性的诊断能力,采用单因素和多因素线性回归分析确定与NLV值相关的因素。

诊断标准与关键数值

  • NLV检测轻度、中度、重度肝脂肪变性的ROC曲线下面积分别为0.953、0.896、0.735;NLV在检测≥轻度或≥中度肝脂肪变性时诊断效能与MRS相当;多因素线性回归显示肝脂肪变性程度是影响NLV值的唯一显著因素(p < 0.001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance of the normalized local variance (NLV) ultrasound technique in the assessment of hepatic steatosis, and to identify the factors that influence the NLV value using histopathological examination as the reference standard.

MATERIALS AND METHODS: Forty male Sprague-Dawley rats were fed a methionine-choline-deficient diet for variable periods (0, 2, 4, 6, 8, 10, or 12 days or 2, 3, or 4 weeks; four rats per group). At the end of each diet duration, magnetic resonance spectroscopy (MRS) and NLV examination were performed. Thereafter, the rats were sacrificed and their livers were histopathologically evaluated. Receiver operating characteristic (ROC) curve analysis was performed to assess the diagnostic capability of the NLV value in the detection of varying degrees of hepatic steatosis. Univariate and multivariate linear regressions were used to determine the factors associated with the NLV value.

RESULTS: The areas under the ROC curve for the detection of mild, moderate, and severe hepatic steatosis were 0.953, 0.896, and 0.735, respectively. The NLV value showed comparable diagnostic performance to that of MRS in the detection of ≥ mild or ≥ moderate hepatic steatosis. Multivariate linear regression analysis revealed that the degree of hepatic steatosis was the only significant factor affecting the NLV value (p < 0.001).

CONCLUSION: The NLV value of ultrasound demonstrated satisfactory diagnostic performance in the assessment of varying degrees of hepatic steatosis. The degree of hepatic steatosis was the only significant factor that affected the NLV value.