文献速递腹部儿科影像泌尿生殖CT

儿童腹盆部CT图像质量比较:不同峰值千伏下低渗对比剂与含碘量较低的等渗对比剂

Comparison of image quality of abdominopelvic CT in paediatric patients: low osmolar contrast media versus less iodine-containing iso-osmolar contrast media at different peak kilovoltages.
PubMed 文献 · Clin Radiol · 2019-08-17

回顾性分析101例低渗对比剂与102例等渗对比剂儿童腹盆部CT,比较不同管电压下图像质量。等渗对比剂组客观强化程度显著较低,但主观强化及图像质量评分组间无统计学差异;作者认为低管电压方案下使用等渗对比剂可行。

要点

  • 等渗对比剂组客观强化程度显著低于低渗对比剂组(p<0.05)。
  • 仅120 kVp条件下主观强化评分低渗对比剂组显著更高(p=0.002)。
  • 主观图像质量评分两组间无统计学差异,低管电压下等渗对比剂可行。

核心结论

  • 低管电压方案下使用等渗对比剂行儿童腹盆部CT是可行的;等渗对比剂组客观强化程度显著较低,但主观强化和图像质量评估组间无统计学差异。

研究设计与样本

  • 回顾性图像分析,低渗对比剂组101例与等渗对比剂组102例儿童(<18岁)腹盆部CT检查,比较不同管电压下图像质量。

关键影像表现/征象

  • 客观测量显示低渗对比剂组强化程度显著更高(p<0.05)。
  • 主观分析中仅120 kVp条件下低渗对比剂组强化显著更强(p=0.002)。

诊断标准与关键数值

  • 四名放射科医师采用四点量表主观评估强化程度、图像噪声、线束硬化伪影及整体图像质量。
  • 区分等渗对比剂的总体敏感度为57.1%,特异度为56.9%。
  • 120 kVp条件下区分等渗对比剂的敏感度为80.6%。

临床应用与阅片要点

  • 儿童腹盆部CT采用低管电压方案时,等渗对比剂可用于图像采集。
  • 阅片时注意等渗对比剂组客观强化程度较低,但主观图像质量与低渗对比剂组无统计学差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the effect of iso-osmolar contrast media (IOCM) at different tube voltages on image quality for abdominal computed tomography (CT) in paediatric patients.

MATERIALS AND METHODS: The low osmolar contrast media (LOCM) group and IOCM group consisted of 101 and 102 CT examinations, respectively, in patients <18 years old. Images were reviewed retrospectively. Objective measurement of the contrast enhancement and noise were analysed and contrast-to-noise ratios (CNRs) of the abdominal aorta, portal vein, and liver were calculated. Four radiologists participated in subjective analysis using a four-point scale system to evaluate degrees of contrast enhancement, image noise, beam-hardening artefact, and overall image quality. Reader performance for correctly differentiating the two kinds of contrast media was evaluated.

RESULTS: Regarding the objective measurement, contrast enhancement was significantly higher in the LOCM group (p<0.05). In subjective analysis, only CT using 120 kVp showed significantly stronger enhancement in the LOCM group (p=0.002), and sensitivity to differentiate the IOCM was 80.6%. Overall sensitivity and specificity for correctly differentiating IOCM were 57.1%, and 56.9%, respectively.

CONCLUSION: The application of IOCM was found to be feasible for performing paediatric abdominopelvic CT with a low tube voltage protocol. Although objective measurements of contrast enhancement were significantly lower in the IOCM group, subjective contrast enhancement and image quality assessments were not statistically different between groups.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Kim M, Hwang JY, Choo KS, et al. Comparison of image quality of abdominopelvic CT in paediatric patients: low osmolar contrast media versus less iodine-containing iso-osmolar contrast media at different peak kilovoltages. Clin Radiol. 2019. PMID: 31431254. doi:10.1016/j.crad.2019.06.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。