文献速递腹部泌尿生殖MR

扩散加权成像视觉评估与表观扩散系数定量诊断急性阑尾炎的准确性、标准及临床意义

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

回顾性纳入51例右下腹痛患者,比较T2WI单独与联合DWI诊断急性阑尾炎的准确性,并测定阑尾及阑尾周围组织ADC值。联合DWI后两名阅片者准确性分别由78.4%和82.4%提升至86.3%。阑尾周围组织低ADC值区分复杂性与非复杂性阑尾炎的准确性达97.1%。

要点

  • T2WI联合DWI诊断急性阑尾炎的准确性高于单独T2WI。
  • 阑尾周围组织ADC值可区分非复杂性与复杂性阑尾炎。
  • 阑尾炎阑尾ADC值低于正常阑尾。

核心结论

  • DWI联合T2WI诊断阑尾炎准确性高,炎症阑尾ADC值低于正常阑尾,阑尾周围组织低ADC值是复杂性阑尾炎的显著表现。

研究设计与样本

  • 回顾性研究纳入51例右下腹痛患者,包括非复杂性阑尾炎25例、复杂性阑尾炎10例、非阑尾炎16例,均行MR检查。
  • 两名放射科医师独立测量阑尾直径和壁厚度,在轴位T2WI上评估壁缺损、脓肿、腔外气体或阑尾结石,并用5分法评估DWI信号强度,测定阑尾及阑尾周围组织ADC值。
  • 采用受试者工作特征分析确定截断值。

关键影像表现/征象

  • 炎症阑尾ADC值低于正常阑尾。
  • 阑尾周围组织呈低ADC值是复杂性阑尾炎的显著表现。

诊断标准与关键数值

  • 诊断急性阑尾炎:仅用T2WI时阅片者1准确性78.4%、阅片者2准确性82.4%,联合T2WI与DWI后两者准确性均为86.3%。
  • 阑尾ADC截断值1.41×10-3 mm2/s诊断阑尾炎准确性78.4%,截断值1.26×10-3 mm2/s准确性76.5%。
  • 阑尾周围组织ADC截断值1.03×10-3 mm2/s与0.91×10-3 mm2/s区分非复杂性与复杂性阑尾炎准确性97.1%。

临床应用与阅片要点

  • 阅片时可结合T2WI与DWI信号评估阑尾炎,并测量阑尾及阑尾周围组织ADC值辅助判断。
  • 阑尾周围组织低ADC值提示复杂性阑尾炎。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis.

METHODS: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis.

RESULTS: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10-3 and 1.26 × 10-3 mm2/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10-3 and 0.91 × 10-3 mm2/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%.

CONCLUSIONS: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Inoue A, Furukawa A, Nitta N, et al. Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis. Abdom Radiol (NY). 2019. PMID: 31420704. doi:10.1007/s00261-019-02180-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。