文献速递腹部MRUS

肝纤维化无创评估:MR弹性成像与瞬时弹性成像及体素内不相干运动扩散加权MRI的比较

Non-invasive assessment of hepatic fibrosis: comparison of MR elastography to transient elastography and intravoxel incoherent motion diffusion-weighted MRI.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

本研究纳入100例慢性肝病患者和25名健康志愿者,对比MR弹性成像(MRE)、瞬时弹性成像(TE)及体素内不相干运动(IVIM)扩散加权MRI对肝纤维化分期的诊断效能。结果显示MRE在判别显著纤维化(≥F2)、晚期纤维化(≥F3)及肝硬化(F4)的AUC均显著高于TE和Dt,而TE与IVIM的诊断效能相当。

要点

  • MRE肝硬度值随纤维化分期升高呈强正相关(r=0.910,P<0.001)。
  • MRE判别≥F2、≥F3、F4的AUC分别为0.965、0.957、0.983,均显著高于TE和Dt(均P<0.05)。
  • TE与IVIM的Dt在判别纤维化分期上除F4外无显著差异(P>0.05)。

核心结论

  • MRE对显著纤维化、晚期纤维化的诊断效能优于TE和IVIM,而TE与IVIM的诊断效能相当。

研究设计与样本

  • 纳入100例慢性肝病患者和25名健康志愿者,术前在3T MRI设备上行MRE和IVIM,并行超声TE;以纤维化分期为参考,比较LSM-MRE、LSM-TE及扩散参数(Dt、假扩散系数、灌注分数f、ADC)的诊断效能。

诊断标准与关键数值

  • LSM-MRE判别≥F2、≥F3、F4的AUC分别为0.965、0.957、0.983。
  • LSM-TE判别≥F2、≥F3、F4的AUC分别为0.906、0.913、0.931。
  • Dt判别≥F2、≥F3、F4的AUC分别为0.875、0.879、0.861。
  • LSM-MRE与LSM-TE值均与纤维化分期正相关(r=0.910和0.813,P<0.001)。
  • Dt、f、ADC值均与纤维化分期负相关(r=-0.727、-0.503、-0.601,均P<0.001)。

临床应用与阅片要点

  • 作者结论认为MRE在预测显著纤维化和晚期纤维化方面诊断效能优异,优于TE和IVIM。
  • 作者结论认为TE与IVIM的诊断效能相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the ability of MR elastography (MRE) with transient elastography (TE) and intravoxel incoherent motion (IVIM) diffusion-weighted MRI in staging hepatic fibrosis (HF).

MATERIALS AND METHODS: 100 patients with chronic liver disease and 25 healthy volunteers underwent preoperative MRE, IVIM on a 3T MRI unit, and ultrasound-based TE. Liver stiffness measurement from MRE (LSM-MRE) and liver stiffness measurement from TE (LSM-TE) were measured; four diffusion parameters including the true diffusion coefficient (Dt), pseudo-diffusion coefficient, perfusion fraction (f), and apparent diffusion coefficient (ADC) were calculated. Receiver operating characteristic (ROC) curves were performed for significant parameters to compare the diagnosis performance for detecting HF.

RESULTS: LSM-MRE and LSM-TE values showed positive correlation with the fibrosis stage (r = 0.910 and 0.813, P < 0.001). Dt, f, and ADC values showed negative correlation with the fibrosis stage (r = - 0.727, - 0.503, and - 0.601, all P < 0.001). The area under the ROC curve (AUC) of LSM-MRE (AUC = 0.965, 0.957, 0.983) was significantly higher than that of LSM-TE (AUC = 0.906, 0.913, 0.931) and Dt (AUC = 0.875, 0.879, 0.861) in discriminating significant HF (≥ F2), advanced HF (≥ F3), or cirrhosis (F4) (all P < 0.05). Although LSM-TE showed higher AUCs than Dt in detecting fibrosis stages, there were no significant differences between LSM-TE and Dt (P > 0.05) except for detecting F4 (P < 0.05).

CONCLUSION: MRE shows excellent diagnostic performance for predicting significant fibrosis, advanced fibrosis compared with TE and IVIM, while TE and IVIM have comparable diagnostic performance.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Fu F, Li X, Chen C, et al. Non-invasive assessment of hepatic fibrosis: comparison of MR elastography to transient elastography and intravoxel incoherent motion diffusion-weighted MRI. Abdom Radiol (NY). 2020. PMID: 31372777. doi:10.1007/s00261-019-02140-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。