不良斑块特征与充血性血流储备分数及瞬时无波形比率的关联强于静息瞬时无波形比率
本PACIFIC试验亚研究前瞻性纳入120例疑似冠心病患者共257支血管,评估CT斑块特征(正性重构、低衰减斑块、点状钙化、餐巾环征)与有创压力指标的关系。多变量分析显示正性重构和点状钙化是FFR受损的独立预测因子,但不良斑块特征与无充血药物iFR无独立关联;CT易损斑块特征与充血性指标(FFR、iFRa)独立相关,而与静息iFR及Pd/Pa无关。
要点
- 正性重构和点状钙化是FFR受损的独立预测因子,但与静息iFR无独立关联。
- CT易损斑块特征与充血性指标FFR及iFRa独立相关,与静息iFR及Pd/Pa无关。
- 狭窄≥70%和斑块体积是FFR与iFR共同的独立相关因素。
核心结论
- CT易损斑块特征与充血性血流指标(FFR和iFRa)独立相关,而与静息iFR和Pd/Pa无独立关联;充血对压力衍生指标的影响可能不仅取决于狭窄的血流动力学严重程度,还取决于斑块特征。
研究设计与样本
- PACIFIC试验的前瞻性子研究,纳入120例疑似冠心病患者(62%男性,年龄58.3±8.6岁),前瞻性评估257支血管;采用256层冠状动脉CT血管成像评估狭窄严重程度和斑块特征(正性重构、低衰减斑块、点状钙化、餐巾环征),并行有创冠状动脉压力测量(FFR、iFR、Pd/Pa及腺苷负荷下无波形期压力比iFRa)。
关键影像表现/征象
- 170支(66%)冠状动脉存在动脉粥样硬化斑块。
- 以血管为单位,管腔狭窄严重程度与FFR、iFR、Pd/Pa及iFRa受损均显著相关。
- 多变量分析显示FFR和iFR均与狭窄≥70%独立相关(分别为-0.10,p<0.001和-0.09,p=0.003),亦与斑块体积独立相关(分别为-0.02,p=0.020和-0.02,p=0.030)。
诊断标准与关键数值
- 多变量分析中,正性重构(-0.10,p<0.001)和点状钙化(-0.07,p=0.021)是FFR受损的独立预测因子。
- 不良斑块特征与无充血药物iFR无独立关联。
- CT斑块特征与有创压力测量指标(FFR、iFR、Pd/Pa、iFRa)进行关联分析。
临床应用与阅片要点
- 阅片时评估CT斑块特征(正性重构、点状钙化等)有助于理解充血性压力指标(FFR、iFRa)的受损机制。
- 静息iFR与CT易损斑块特征无独立关联,解读iFR时需注意其与充血性指标反映的信息可能不同。
- 狭窄≥70%和斑块体积与FFR及iFR均独立相关,报告时需同时关注狭窄程度和斑块负荷。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The current substudy of the PACIFIC (Prospective Comparison of Cardiac PET/CT, SPECT/CT Perfusion Imaging and CT Coronary Angiography With Invasive Coronary Angiography) trial explores the impact of computed tomography (CT)-derived unfavorable plaque features on both hyperemic and non-hyperemic flow indices.
BACKGROUND: Next to lesion severity, plaque vulnerability as assessed using coronary CT angiography affects fractional flow reserve (FFR), which is associated with imminent acute coronary syndromes. Instantaneous wave-free ratio (iFR) has recently emerged as an alternative for FFR to interrogate coronary lesions for ischemia. It is, however, unknown whether vasodilator-free assessment with iFR is associated with plaque stability similarly as FFR.
METHODS: Of 120 patients (62% men, age 58.3 ± 8.6 years) with suspected coronary artery disease, 257 vessels were prospectively evaluated. Each patient underwent 256-slice coronary CT angiography to assess stenosis severity and plaque features (positive remodeling [PR], low attenuation plaque [LAP], spotty calcification [SC], and napkin ring sign [NRS]), as well as intracoronary pressure measurements (FFR, iFR, Pd/Pa, and pressure ratio during adenosine within the wave-free period [iFRa]). CT-derived plaque characteristics were related to these invasive pressure measurements.
RESULTS: Atherosclerotic plaques were present in 170 (66%) coronary arteries. On a per-vessel basis, luminal stenosis severity was significantly associated with impaired FFR, iFR, Pd/Pa, and iFRa. Multivariable analysis revealed that FFR and iFR were independently related to ≥70% stenosis (-0.10, p < 0.001 and -0.09, p = 0.003, respectively) and plaque volume (-0.02, p = 0.020 and -0.02, p = 0.030, respectively). Additionally, PR and SC were also independent predictors of an impaired FFR (-0.10, p < 0.001 and -0.07, p = 0.021, respectively), but adverse plaque characteristics were not independently related to the vasodilator-free iFR.
CONCLUSIONS: CT-derived vulnerable plaque characteristics are independently associated with hyperemic flow indices as assessed with FFR and iFRa, but not with non-hyperemic indices such as iFR and Pd/Pa. These findings suggest that the effects of hyperemia on pressure-derived indices might depend not only on hemodynamic stenosis severity but also on plaque characteristics.
引用
- Driessen RS, de Waard GA, Stuijfzand WJ, et al. Adverse Plaque Characteristics Relate More Strongly With Hyperemic Fractional Flow Reserve and Instantaneous Wave-Free Ratio Than With Resting Instantaneous Wave-Free Ratio. JACC Cardiovasc Imaging. 2019. PMID: 31422133. doi:10.1016/j.jcmg.2019.06.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。