半自动胎儿智能导航超声心动图即使在经验较少者手中也有助于心脏评估
研究对30例孕中期胎儿的时空图像相关容积数据集,由3位不同经验水平的医师用FINE方法评估,分析检查时间和诊断切面重建,并在4周培训后复评观察者间和观察者内变异。结果显示初学者在复评时明显改善,先进者和专家未见进一步改善;FINE技术可靠且易于学习,半自动流程有助于标准化和节省时间地评估胎儿心脏。
要点
- FINE半自动流程可在所有30个容积数据集上完成检查。
- 初学者在4周培训后诊断切面正确显示明显改善(P=.0087)。
- 先进者和专家在复评时未见进一步改善(P>.999;P=.8383)。
核心结论
- FINE技术可靠且易于学习,半自动工作流程支持标准化和节省时间地评估胎儿心脏,可能有助于检测胎儿心脏异常。
研究设计与样本
- 研究对30例孕中期胎儿的时空图像相关容积数据集,由3位胎儿超声心动图经验水平不同的医师用FINE方法评估,分析检查时间和诊断切面正确重建,并由盲法专家评估所有诊断切面的完成情况和正确显示数量(时间t0),4周培训后复评(时间t1)以确定观察者间和观察者内变异。
关键影像表现/征象
- 所有操作者均能在全部30个容积数据集上完成检查。
- 在t0时,初学者与先进者(P=.0013)及专家(P<.0001)之间的观察者间变异高。
- 在t1时,初学者观察者内变异明显改善(P=.0087),而先进者和专家在正确实现所有诊断切面方面未见进一步改善(P>.999;P=.8383)。
临床应用与阅片要点
- FINE半自动工作流程可用于标准化和节省时间地评估胎儿心脏。
- 作者认为半自动评估胎儿心脏可能有助于检测胎儿心脏异常。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the interobserver and intraobserver variability and corresponding learning curve in a semiautomatic approach for a standardized assessment of the fetal heart (fetal intelligent navigation echocardiography [FINE]).
METHODS: A total of 30 stored spatiotemporal image correlation volume data sets of second-trimester fetuses were evaluated by 3 physicians with different levels of expertise in fetal echocardiography by using the FINE approach. Data were analyzed regarding the examination time and proper reconstruction of the diagnostic cardiac planes. The completions and numbers of correct depictions of all diagnostic planes were evaluated by a blinded expert (time t0). To determine interobserver and intraobserver variability, the volumes were reassessed after a 4-week training interval (time t1).
RESULTS: All operators were able to perform the investigation on all 30 volumes. At t0, the interobserver variability between the beginner and both the advanced (P = .0013) and expert (P < .0001) examiners was high. Focusing on intraobserver variability at t1, the beginner showed a marked improvement (P = .0087), whereas in advanced and expert hands, no further improvement regarding proper achievement of all diagnostic planes could be noticed (P > .999; P = .8383). The beginner also showed improvement in the mean investigation time (t0, 82.8 seconds; t1, 73.4 seconds; P = .0895); nevertheless, the advanced and expert examiners were faster in completing the examination (t1, advanced, 20.9 seconds; expert, 28.3 seconds; each P < .0001).
CONCLUSIONS: Based on our results, the FINE technique is a reliable and easily learned method. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized and time-saving manner. A semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.
引用
- Gembicki M, Hartge DR, Dracopoulos C, et al. Semiautomatic Fetal Intelligent Navigation Echocardiography Has the Potential to Aid Cardiac Evaluations Even in Less Experienced Hands. J Ultrasound Med. 2019. PMID: 31411353. doi:10.1002/jum.15105
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。