文献速递心血管外周血管MR

应用四维血流磁共振成像评估法洛四联症修复术后患者升主动脉的血流模式

Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging.
PubMed 文献 · Korean J Radiol · 2019-01-01

本研究纳入44例法洛四联症修复术后患者和11名志愿者,采用四维血流磁共振成像评估升主动脉血流模式,发现修复术后组升主动脉扩张、血流喷射角增大、壁面剪切应力降低;亚组分析显示主动脉扩张组TOF修复时年龄更高、升主动脉水平血流喷射角更大、平均壁面剪切应力更低。

要点

  • TOF修复术后患者升主动脉窦部、窦管交界及中段升主动脉直径显著大于志愿者。
  • TOF修复术后患者窦管交界和升主动脉水平血流喷射角显著增大,流速和壁面剪切应力显著降低。
  • TOF修复术后主动脉扩张组修复时年龄更高、升主动脉水平血流喷射角更大、平均壁面剪切应力更低。

核心结论

  • 法洛四联症修复术后患者血流喷射角增大、升主动脉扩张并继发性壁面剪切应力降低;除已知危险因素外,血流偏心性可能影响法洛四联症修复术后患者的主动脉扩张。

研究设计与样本

  • 研究纳入44例法洛四联症修复术后患者(男25例、女19例,平均年龄28.9±8.4岁)和11名志愿者(男10例、女1例,平均年龄33.7±8.8岁),均接受四维血流磁共振成像检查。

关键影像表现/征象

  • 法洛四联症修复术后组Valsalva窦、窦管交界和中段升主动脉直径均显著高于志愿者组(分别为p=0.002、p<0.001、p=0.013)。
  • 法洛四联症修复术后组窦管交界和升主动脉水平血流喷射角显著大于志愿者组(分别为p<0.001和p=0.003),流速和壁面剪切应力参数显著降低。
  • 血流位移在法洛四联症修复术后组与志愿者组间无统计学显著差异(p=0.817)。
  • 主动脉扩张组血流位移高于非扩张组,但无统计学显著性(p=0.217)。

诊断标准与关键数值

  • 法洛四联症修复术后组与志愿者组比较:Valsalva窦直径p=0.002、窦管交界直径p<0.001、中段升主动脉直径p=0.013,均为修复术后组显著更高。
  • 法洛四联症修复术后组与志愿者组比较:窦管交界血流喷射角p<0.001、升主动脉血流喷射角p=0.003,均为修复术后组显著更大;流速和壁面剪切应力参数显著更低;血流位移p=0.817。
  • 主动脉扩张组与非扩张组比较:修复时年龄p=0.039(扩张组更高)、升主动脉水平血流喷射角p=0.003(扩张组更大)、平均壁面剪切应力p=0.039(扩张组更低)、血流位移p=0.217(无统计学显著性)。

临床应用与阅片要点

  • 四维血流磁共振成像可定量评估法洛四联症修复术后升主动脉血流喷射角、壁面剪切应力和血流位移等血流动力学参数。
  • 阅片时需关注窦管交界和升主动脉水平的血流喷射角增大及壁面剪切应力降低,这些参数与主动脉扩张相关。
  • 主动脉扩张组修复时年龄更高、升主动脉水平血流喷射角更大、平均壁面剪切应力更低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate flow pattern characteristics in the ascending aorta (AA) with four-dimensional (4D)-flow MRI and to determine predictors of aortic dilatation late after tetralogy of Fallot (TOF) repair.

MATERIALS AND METHODS: This study included 44 patients with repaired TOF (25 males and 19 females; mean age, 28.9 ± 8.4 years) and 11 volunteers (10 males and 1 female, mean age, 33.7 ± 8.8 years) who had undergone 4D-flow MRI. The aortic diameters, velocity, wall shear stress (WSS), flow jet angle (FJA), and flow displacement (FD) at the level of the sinotubular junction (STJ) and mid-AA were compared between the repaired TOF and volunteer groups. The hemodynamic and clinical parameters were also compared between the aortic dilatation and non-dilatation subgroups in the repaired TOF group.

RESULTS: The diameters of the sinus of Valsalva, STJ, and AA were significantly higher in the repaired TOF group than in the volunteer group (p = 0.002, p < 0.001, and p = 0.013, respectively). The FJAs at the STJ and AA were significantly greater in the repaired TOF group (p < 0.001 and p = 0.003, respectively), while velocities and WSS parameters were significantly lower. FD showed no statistically significant difference (p = 0.817). In subgroup analysis, age at TOF repair was significantly higher (p = 0.039) and FJA at the level of the AA significantly greater (p = 0.003) and mean WSS were significantly lower (p = 0.039) in the aortic dilatation group. FD were higher in the aortic dilatation group without statistical significance (p = 0.217).

CONCLUSION: Patients with repaired TOF have an increased FJA, dilated AA, and secondarily decreased WSS. In addition to known risk factors, flow eccentricity may affect aortic dilatation in patients with repaired TOF.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee S, Kim YJ, Jung JW, et al. Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging. Korean J Radiol. 2019. PMID: 31464112. doi:10.3348/kjr.2019.0096

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。