文献速递心血管儿科影像胸部CT

新生儿先天性心脏病术前诊断中的心脏CT:通过省略测试团注或团注追踪实现辐射剂量优化

Cardiac CT in the Preoperative Diagnostics of Neonates with Congenital Heart Disease: Radiation Dose Optimization by Omitting Test Bolus or Bolus Tracking.
PubMed 文献 · Acad Radiol · 2019-08-20

这项回顾性研究纳入25例2009至2018年接受高螺距CTA的先天性心脏病新生儿,采用手工注射对比剂(1.5 ml/kg体重)和固定扫描延迟、省略测试团注或团注追踪。所有检查均可诊断且无不良事件,中位CTDIvol为0.50 mGy、剂量长度乘积为8 mGy×cm,蒙特卡洛模拟有效剂量中位0.66 mSv,图像质量评分1.2±0.4、对比噪声比16.1±7.0,与术中所见对照诊断准确率100%。作者结论认为该方案安全、可降低剂量并提供详细心脏解剖信息。

要点

  • 新生儿先心病高螺距CTA省略测试团注或团注追踪,中位CTDIvol 0.50 mGy、有效剂量中位0.66 mSv。
  • 全部25例检查均可诊断、无不良事件,平均图像质量评分1.2±0.4、对比噪声比16.1±7.0。
  • 与术中对照诊断准确率100%,心脏解剖未见新诊断或显著差异。

核心结论

  • 新生儿先心病心脏高螺距CTA省略额外测试团注或团注追踪扫描可安全、降低剂量地完成,图像质量很好,能提供详细心脏解剖信息以支持个体化无创治疗规划。

研究设计与样本

  • 回顾性研究,纳入2009至2018年25例先天性心脏病新生儿,行高螺距CTA(螺距3.4、80 kV),手工注射对比剂1.5 ml/kg体重,按各自心脏缺陷设定固定扫描延迟,评估诊断、不良事件、辐射剂量参数、客观(对比噪声比)与主观(4点Likert量表)图像质量,并与术中所见对照诊断准确率。

关键影像表现/征象

  • 所有检查均可诊断评估,无不良事件。
  • 图像仅有极轻微噪声,平均图像质量评分1.2±0.4,平均对比噪声比16.1±7.0。
  • 后续心脏手术中未发现新诊断或显著差异,诊断准确率100%。

诊断标准与关键数值

  • 中位CT剂量指数容积(CTDIvol)0.50 mGy(范围0.15–0.94)。
  • 中位剂量长度乘积8 mGy×cm(范围3–17)。
  • 蒙特卡洛模拟估算有效剂量中位0.66 mSv(范围0.25–1.40 mSv),低于既往同类组发表水平。
  • 主观图像质量采用4点Likert量表,平均评分1.2±0.4。

临床应用与阅片要点

  • 对新生儿先心病CTA,可采用高螺距(3.4)、80 kV、手工注射1.5 ml/kg对比剂并按心脏缺陷设定固定扫描延迟,省略测试团注或团注追踪以降低剂量。
  • 作者结论认为该方案安全、可降低剂量,图像质量很好,能提供详细心脏解剖信息并支持个体化无创治疗规划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Congenital heart diseases (CHD) belong to the leading causes of infant mortality worldwide. Prognostic improvements result from multimodal therapy strategies leading to an increased demand for noninvasive imaging. The aim of the study was to further optimize cardiac CT radiation dose by omitting the test bolus or bolus tracking scan, which can have a relevant share of radiation exposure, especially in neonates.

MATERIALS AND METHODS: This retrospective study included 25 neonates with CHD who received a CT angiography (CTA) from 2009 to 2018. The examinations were performed as a high-pitch CTA (pitch 3.4, 80 kV) with manual contrast administration (1.5 ml/kg body weight) and fixed scan delay depending on the respective heart defect. Diagnosis, adverse events, radiation dose parameters, objective (contrast-to-noise ratio) and subjective (4-point Likert scale) image quality as well as diagnostic accuracy compared to intraoperative findings was assessed.

RESULTS: All examinations were diagnostically evaluable without adverse events. The median CT dose index volume (CTDIvol) was 0.50 mGy (range, 0.15-0.94), the median dose-length product was 8 mGy × cm (range, 3-17). The estimation of the effective dose by Monte Carlo simulation revealed lower median dose levels 0.66 mSv (range, 0.25-1.40 mSv) than previously published in comparable groups. All examinations achieved a very good mean image quality score of 1.2 ± 0.4 with only minimal image noise and mean contrast-to-noise ratio of 16.1 ± 7.0. Diagnostic accuracy was 100 % as cardiac anatomy revealed no new diagnoses or significant differences in the subsequent cardiac surgery.

CONCLUSION: Cardiac high-pitch CTA of neonates with CHD can be performed safely and dose-reducing without additional test bolus or bolus tracking scan. With very good image quality, it provides a detailed insight into the cardiac anatomy and thus enables a differentiated, noninvasive therapy planning.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Schindler P, Kehl HG, Wildgruber M, et al. Cardiac CT in the Preoperative Diagnostics of Neonates with Congenital Heart Disease: Radiation Dose Optimization by Omitting Test Bolus or Bolus Tracking. Acad Radiol. 2019. PMID: 31444109. doi:10.1016/j.acra.2019.07.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。