文献速递心血管MR

压缩感知实时电影成像在临床实践中评估心室功能、容积与质量

Compressed sensing real-time cine imaging for assessment of ventricular function, volumes and mass in clinical practice.
PubMed 文献 · Eur Radiol · 2019-08-01

本研究对100例连续患者采用压缩感知单次屏气实时电影序列与参考分段多次屏气稳态自由进动序列进行心脏磁共振电影成像,比较左右心室射血分数、舒张末期容积及左心室质量。结果显示两种序列相关性极佳,压缩感知序列将扫描时间从510±109秒缩短至23±6秒,瓣膜反流与室壁运动障碍显示无临床相关信息的丢失。

要点

  • 压缩感知单次屏气实时电影序列与常规多次屏气SSFP序列测得的左右心室功能参数相关性极佳(r≥0.979)。
  • 压缩感知序列平均扫描时间23±6秒,显著短于多次屏气SSFP序列的510±109秒(p<0.001)。
  • 压缩感知图像对二尖瓣或三尖瓣反流显示良好(AUC分别为0.85和0.81),对室壁运动障碍显示极佳(AUC≥0.97)。

核心结论

  • 压缩感知实时单次屏气电影成像在日常实践中将心脏磁共振扫描时间缩短近20倍,同时提供可靠的左右心室测量,瓣膜反流和室壁运动障碍显示无临床相关信息丢失。

研究设计与样本

  • 研究纳入100例连续患者,采用心脏磁共振电影成像,同时采集参考分段多次屏气稳态自由进动序列和原型单次屏气实时压缩感知序列,两种序列提供相同的层数、位置和厚度。

关键影像表现/征象

  • 压缩感知序列平均扫描时间为23±6秒,多次屏气稳态自由进动序列为510±109秒(p<0.001)。
  • 压缩感知图像上二尖瓣反流显示良好(AUC=0.85),三尖瓣反流显示良好(AUC=0.81)。
  • 压缩感知图像上室壁运动障碍显示极佳(AUC≥0.97)。

诊断标准与关键数值

  • 左心室射血分数两种序列间相关系数r=0.995。
  • 左心室舒张末期容积相关系数r=0.997。
  • 左心室质量相关系数r=0.981。
  • 右心室射血分数相关系数r=0.979。
  • 右心室舒张末期容积相关系数r=0.983。

临床应用与阅片要点

  • 压缩感知实时单次屏气电影序列可用于日常实践中评估左右心室功能、容积和质量。
  • 该序列可缩短心脏磁共振扫描时间并改善患者工作流程。
  • 阅片时压缩感知图像对瓣膜反流和室壁运动障碍的显示无临床相关信息丢失。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study was conducted in order to evaluate the accuracy of a compressed sensing (CS) real-time single-breath-hold cine sequence for the assessment of left and right ventricular functional parameters in daily practice.

METHODS: Cardiac magnetic resonance (CMR) cine images were acquired from 100 consecutive patients using both the reference segmented multi-breath-hold steady-state free precession (SSFP) acquisition and a prototype single-breath-hold real-time CS sequence, providing the same slice number, position, and thickness. For both sequences, the left (LV) and right ventricular (RV) ejection fractions (EF) and end-diastolic volumes (EDV) were assessed as well as LV mass (LVM). The visualization of wall-motion disorders (WMD) and signal void related to mitral or tricuspid regurgitation was also analyzed.

RESULTS: The CS sequence mean scan time was 23 ± 6 versus 510 ± 109 s for the multi-breath-hold SSFP sequence (p < 0.001). There was an excellent correlation between the two sequences regarding mean LVEF (r = 0.995), LVEDV (r = 0.997), LVM (r = 0.981), RVEF (r = 0.979), and RVEDV (r = 0.983). Moreover, inter- and intraobserver agreements were very strong with intraclass correlations of 0.96 and 0.99, respectively. On CS images, mitral or tricuspid regurgitation visualization was good (AUC = 0.85 and 0.81, respectively; ROC curve analysis) and wall-motion disorder visualization was excellent (AUC ≥ 0.97).

CONCLUSION: CS real-time single-breath-hold cine imaging reduces CMR scan duration by almost 20 times in daily practice while providing reliable measurements of both left and right ventricles. There was no clinically relevant information loss regarding valve regurgitation and wall-motion disorder depiction.

KEY POINTS: • Compressed sensing single-breath-hold real-time cine imaging is a reliable sequence in daily practice. • Fast CS real-time imaging reduces CMR scan time and improves patient workflow. • There is no clinically relevant information loss with CS regarding heart valve regurgitation or wall-motion disorders.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Vermersch M, Longère B, Coisne A, et al. Compressed sensing real-time cine imaging for assessment of ventricular function, volumes and mass in clinical practice. Eur Radiol. 2019. PMID: 31372784. doi:10.1007/s00330-019-06341-2