文献速递心血管MR

使用压缩感知与运动校正的完全自由呼吸腺苷负荷心脏MRI:与标准屏气检查的功能参数、灌注及延迟强化比较

Complete Free-breathing Adenosine Stress Cardiac MRI Using Compressed Sensing and Motion Correction: Comparison of Functional Parameters, Perfusion, and Late Enhancement with the Standard Breath-holding Examination.
PubMed 文献 · Radiol Cardiothorac Imaging · 2019-08-22

前瞻性纳入40例连续患者行3-T MRI,比较自由呼吸(FB)与屏气(BH)腺苷负荷心脏MRI的功能、灌注及延迟强化。FB与BH功能参数一致性良好,灌注缺损范围、LGE及诊断信心相当。作者认为FB腺苷负荷心脏MRI可提供诊断级图像质量,可能成为无法配合多次屏气及长时间检查患者的替代方案。

要点

  • FB与BH的左、右心室功能参数Bland-Altman分析一致性良好。
  • BH左心室主观图像质量显著优于FB(P < .01),右心室两者相当(P > .99)。
  • 灌注缺损范围、LGE及诊断信心在FB与BH间相当。

核心结论

  • 自由呼吸腺苷负荷心脏MRI可提供诊断级图像质量,可能成为无法满足多次屏气及长时间检查要求患者的替代选择。

研究设计与样本

  • 前瞻性纳入40例连续患者,使用3-T MRI行功能成像、灌注及延迟钆强化序列,均分别采集屏气与自由呼吸(压缩感知联合在线运动校正)图像。
  • 以屏气检查为参考标准,采用Bland-Altman图和线性混合模型比较左、右心室功能参数。
  • 主观图像质量采用五分法评分(1=不可诊断,5=很好);灌注与LGE的诊断信心采用三分法评分(1=低,3=高),图像质量采用五分法评分;采用Wilcoxon检验比较图像质量与诊断信心。

诊断标准与关键数值

  • 左、右心室功能参数在屏气与自由呼吸序列间Bland-Altman分析显示良好一致性。
  • 左心室主观图像质量屏气序列显著更优(P < .01),右心室两者相当(P > .99)。
  • 灌注缺损范围、LGE及诊断信心在两组间相当。

临床应用与阅片要点

  • 电影序列扫描时间屏气为218秒(范围130-385秒),自由呼吸为16秒(范围11-27秒)。
  • LGE序列扫描时间屏气为371秒(范围239-502秒),自由呼吸为189秒(范围122-286秒)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare free-breathing (FB) stress cardiac MRI examinations with the reference standard breath-holding (BH) examination.

MATERIALS AND METHODS: A total of 40 consecutive patients were enrolled prospectively and were examined with 3-T MRI. Functional imaging, perfusion, and late gadolinium enhancement (LGE) sequences were performed in BH and FB by using compressed sensing and in-line motion correction. Left ventricle (LV) and right ventricle (RV) functional parameters in BH and FB examinations were compared by using Bland-Altman plots and linear mixed models. Subjective image quality was assessed with a five-point scale (1 = nondiagnostic, 5 = very good). For perfusion and LGE imaging, diagnostic confidence was rated with a three-point scale (1 = low, 3 = high), and image quality was rated with a five-point scale (1 = nondiagnostic, 5 = very good). The Wilcoxon test was used to compare image quality and diagnostic confidence.

RESULTS: Bland-Altman plots showed good agreement for LV and RV functional parameters in BH and FB sequences. Subjective image quality was significantly better with the BH sequences in the LV (P < .01) but was comparable in the RV (P > .99). Scanning time was 218 seconds (range, 130-385 seconds) for cine BH and 16 seconds (range, 11-27 seconds) for cine FB. Extent of perfusion defects, LGE, and diagnostic confidence was comparable between groups. Scanning time was 371 seconds (range, 239-502 seconds) for the LGE BH sequence and 189 seconds (range, 122-286 seconds) for the LGE FB sequence.

CONCLUSION: FB adenosine stress cardiac MRI delivers diagnostic image quality and could represent an alternative for use in patients who are unable to meet the demands of multiple BHs and long examination times.© RSNA, 2019.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Treutlein C, Wiesmüller M, May MS, et al. Complete Free-breathing Adenosine Stress Cardiac MRI Using Compressed Sensing and Motion Correction: Comparison of Functional Parameters, Perfusion, and Late Enhancement with the Standard Breath-holding Examination. Radiol Cardiothorac Imaging. 2019. PMID: 33778508. doi:10.1148/ryct.2019180017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。