文献速递心血管CTDSA

采用新型计算流体力学算法的CT FFR用于缺血特异性冠状动脉疾病:一项中国多中心研究

CT FFR for Ischemia-Specific CAD With a New Computational Fluid Dynamics Algorithm: A Chinese Multicenter Study.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-08-14

该研究在中国9个医学中心回顾性纳入338例患者共422支血管,评估基于新型计算流体力学(CFD)的CT FFR(uCT-FFR)以有创FFR为参考标准检测病变特异性缺血的表现。结果显示uCT-FFR在各病变(包括中间病变)中的特异度、准确度和AUC均高于CTA和有创造影定性评估,且在灰区和钙化评分≥400与<400的患者间诊断性能无显著差异。

要点

  • uCT-FFR以有创FFR为参考,每支血管敏感度0.89、特异度0.91、准确度0.91。
  • 在中间病变(管腔狭窄30%至70%)中uCT-FFR特异度、准确度和AUC均高于CTA和有创造影(p < 0.001)。
  • 钙化评分≥400与<400患者间uCT-FFR诊断性能无显著差异(p = 0.393)。

核心结论

  • 这种新型基于计算流体力学的CT FFR方法在检测病变特异性缺血方面表现出良好性能,优于CTA和有创造影定性评估,尤其在中间病变中最为突出,并可能在灰区和重度钙化病变中具有诊断能力。

研究设计与样本

  • 回顾性分析中国9个医学中心338例连续患者共422支血管,均行冠状动脉CTA和有创FFR;CT FFR值通过新型现场计算流体力学CT FFR(uCT-FFR,版本1.5,United-Imaging Healthcare,上海,中国)获得;以有创FFR为参考标准。

诊断标准与关键数值

  • 以有创FFR为参考标准,uCT-FFR每支血管敏感度0.89、特异度0.91、准确度0.91;CTA敏感度0.92、特异度0.34、准确度0.55;有创造影敏感度0.94、特异度0.37、准确度0.58。

临床应用与阅片要点

  • 作者指出uCT-FFR在中间病变中诊断性能优于CTA和有创造影定性评估,并可能对灰区(FFR 0.75至0.80)和重度钙化病变具有诊断能力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to validate the feasibility of a novel structural and computational fluid dynamics-based fractional flow reserve (FFR) algorithm for coronary computed tomography angiography (CTA), using alternative boundary conditions to detect lesion-specific ischemia.

BACKGROUND: A new model of computed tomographic (CT) FFR relying on boundary conditions derived from structural deformation of the coronary lumen and aorta with transluminal attenuation gradient and assumptions regarding microvascular resistance has been developed, but its accuracy has not yet been validated.

METHODS: A total of 338 consecutive patients with 422 vessels from 9 Chinese medical centers undergoing CTA and invasive FFR were retrospectively analyzed. CT FFR values were obtained on a novel on-site computational fluid dynamics-based CT FFR (uCT-FFR [version 1.5, United-Imaging Healthcare, Shanghai, China]). Performance characteristics of uCT-FFR and CTA in detecting lesion-specific ischemia in all lesions, intermediate lesions (luminal stenosis 30% to 70%), and "gray zone" lesions (FFR 0.75 to 0.80) were calculated with invasive FFR as the reference standard. The effect of coronary calcification on uCT-FFR measurements was also assessed.

RESULTS: Per vessel sensitivities, specificities, and accuracies of 0.89, 0.91, and 0.91 with uCT-FFR, 0.92, 0.34, and 0.55 with CTA, and 0.94, 0.37, and 0.58 with invasive coronary angiography, respectively, were found. There was higher specificity, accuracy, and AUC for uCT-FFR compared with CTA and qualitative invasive coronary angiography in all lesions, including intermediate lesions (p < 0.001 for all). No significant difference in diagnostic accuracy was observed in the "gray zone" range versus the other 2 lesion groups (FFR ≤0.75 and >0.80; p = 0.397) and in patients with "gray zone" versus FFR ≤0.75 (p = 0.633) and versus FFR >0.80 (p = 0.364), respectively. No significant difference in the diagnostic performance of uCT-FFR was found between patients with calcium scores ≥400 and <400 (p = 0.393).

CONCLUSIONS: This novel computational fluid dynamics-based CT FFR approach demonstrates good performance in detecting lesion-specific ischemia. Additionally, it outperforms CTA and qualitative invasive coronary angiography, most notably in intermediate lesions, and may potentially have diagnostic power in gray zone and highly calcified lesions.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Tang CX, Liu CY, Lu MJ, et al. CT FFR for Ischemia-Specific CAD With a New Computational Fluid Dynamics Algorithm: A Chinese Multicenter Study. JACC Cardiovasc Imaging. 2019. PMID: 31422138. doi:10.1016/j.jcmg.2019.06.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。