文献速递心血管技术与安全MR

低场磁共振成像在心脏节律管理设备患者中的安全性和有效性

Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices.
PubMed 文献 · Eur J Radiol · 2019-07-09

研究纳入338例植入心脏节律管理设备的患者,评估0.2 T低场MRI的安全性和诊断效率。除1例因反复严重恶心中断外,所有扫描均可有效分析,未诱发心律失常或抑制起搏器功能,设备参数无显著变化。低场MRI对起搏器依赖及废弃导线患者亦安全有效。

要点

  • 0.2 T低场MRI在起搏器、ICD及CRT患者中未诱发心律失常或抑制起搏器功能。
  • 除1例因反复严重恶心中断外,所有446个感兴趣区扫描均可有效分析。
  • 起搏器依赖患者及废弃导线患者行低场MRI亦未见临床或技术并发症。

核心结论

  • 0.2 T低场MRI在心脏节律管理设备患者中临床和技术并发症方面有效且安全,即使存在起搏器依赖或废弃导线。

研究设计与样本

  • 研究纳入338例植入心脏节律管理设备的患者,评估446个感兴趣区的0.2 T MRI扫描。
  • 设备包括298台起搏器、25台ICD、8台CRT-ICD和7台CRT起搏器。
  • 患者中62例(18.3%)为起搏器依赖,52例(15.4%)植入1.5 T磁共振条件兼容起搏器,13例(3.9%)存在废弃导线。
  • 患者62%为男性,MRI扫描时年龄76.1 ± 9.2岁,设备植入后时间4.1 ± 3.2年。

诊断标准与关键数值

  • 与MRI前设备 interrogation 相比,电池电压、起搏捕获阈值、内源性ECG感知、导线阻抗以及ICD设备的 shock 阻抗在检查后均无显著变化。

临床应用与阅片要点

  • 0.2 T低场MRI可用于心脏节律管理设备患者的影像检查,包括起搏器依赖和废弃导线患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Low-field magnetic resonance imaging (MRI), i.e. MRI with a static magnetic field strength <0.5 T, has been reported to be safe in patients with pacemakers, however there are no data about the safety of low-field MRI in patients with implantable cardioverter defibrillators (ICD) and/or cardiac resynchronization therapy (CRT). We aimed to investigate the safety and diagnostic efficiency of routine low-field MRI in patients with different devices for cardiac rhythm management (i.e. pacemakers and ICD, including devices with CRT).

METHOD: MRI scans of 446 regions of interest were evaluated with field strength of 0.2 T in 338 patients (62% male; age at MRI scan 76.1 ± 9.2 years; time since device implantation 4.1 ± 3.2 years) with cardiac rhythm management devices (298 pacemakers, 25 ICD, 8 CRT-ICD, and 7 CRT pacemakers). This analysis included 62 pacemaker-dependent patients (18.3%), 52 patients with 1.5-Tesla-MR conditional pacemakers (15.4%) and 13 patients with abandoned leads (3.9%).

RESULTS: Except for one examination, which was interrupted because of recurrent severe nausea, all MRI scans could be analyzed efficiently. No induction of arrhythmia or inhibition of pacemaker function occurred. Compared to the device interrogation before MRI, there were no significant changes in battery voltage, pacing capture threshold, sensing of intrinsic ECG, lead impedance, as well as shock impedance in ICD devices after completed examination.

CONCLUSIONS: Low-field MRI examinations (0.2 T) were efficient and safe regarding clinical and technical complications in patients with devices for cardiac rhythm management, even in case of pacemaker-dependency or the presence of abandoned leads.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Schukro C, Puchner SB. Safety and efficiency of low-field magnetic resonance imaging in patients with cardiac rhythm management devices. Eur J Radiol. 2019. PMID: 31439265. doi:10.1016/j.ejrad.2019.07.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。