文献速递心血管CT

疑似支架内再狭窄或冠状动脉疾病进展患者中CT灌注与冠状动脉CT血管成像的比较

CT Perfusion Versus Coronary CT Angiography in Patients With Suspected In-Stent Restenosis or CAD Progression.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-08-14

本研究连续纳入150例既往冠状动脉支架置入并转诊行有创冠状动脉造影的稳定患者,比较冠状动脉CTA、腺苷负荷CTP及两者联合以有创冠状动脉造影和有创FFR为标准诊断支架内再狭窄或疾病进展的性能。CTP的诊断率与诊断准确率均显著高于冠状动脉CTA,联合评估诊断准确率最高,冠状动脉CTA+CTP辐射暴露为4.15±1.5 mSv。

要点

  • 在既往支架置入患者中,CTP的诊断率显著高于冠状动脉CTA(患者水平96% vs 68%;p<0.0001)。
  • 以有创冠状动脉造影为标准,CTP诊断准确率显著高于冠状动脉CTA(区域水平92.1% vs 85.5%,p<0.03;患者水平86.7% vs 76.7%,p<0.03)。
  • 冠状动脉CTA+CTP联合评估的诊断准确率最高(区域水平95.8%)。

核心结论

  • 在冠状动脉支架置入患者中,与单独冠状动脉CTA相比,CTP显著提高了诊断率与诊断准确率,对照标准包括有创冠状动脉造影和有创FFR。

研究设计与样本

  • 连续纳入既往冠状动脉支架置入的稳定患者150例(132例男性,平均年龄65.1±9.1岁),均行负荷心肌CTP及静息CTP+冠状动脉CTA,使用16 cm Z轴覆盖扫描仪;临床需要时在有创冠状动脉造影中行有创FFR;以有创冠状动脉造影和有创FFR为临床标准,进行支架水平、区域水平和患者水平分析。

诊断标准与关键数值

  • CTP诊断率显著高于冠状动脉CTA:区域水平96.7% vs 91.1%(p<0.0001),患者水平96% vs 68%(p<0.0001)。
  • 以有创冠状动脉造影为标准,CTP诊断准确率显著高于冠状动脉CTA:区域水平92.1% vs 85.5%(p<0.03),患者水平86.7% vs 76.7%(p<0.03)。
  • 冠状动脉CTA+CTP联合评估的诊断准确率最高:区域水平95.8%。
  • CTP诊断准确率显著高于冠状动脉CTA:75% vs 30.5%(p<0.001)。

临床应用与阅片要点

  • 在既往冠状动脉支架置入患者中,CTP可显著提高诊断率与诊断准确率,联合冠状动脉CTA+CTP评估诊断准确率最高(区域水平95.8%)。
  • 冠状动脉CTA+CTP的辐射暴露为4.15±1.5 mSv。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The goal of this study was to assess the diagnostic performance of coronary computed tomography angiography (CTA) alone, adenosine-stress myocardial perfusion assessed by computed tomography (CTP) alone, and coronary CTA + CTP by using a 16-cm Z-axis coverage scanner versus invasive coronary angiography (ICA) and fractional flow reserve (FFR) as the clinical standard.

BACKGROUND: Diagnostic performance of coronary CTA for in-stent restenosis detection is still challenging. Recently, CTP showed additional diagnostic power over coronary CTA in patients with suspected coronary artery disease. However, few data are available on CTP performance in patients with previous stent implantation.

METHODS: Consecutive stable patients with previous coronary stenting referred for ICA were enrolled. All patients underwent stress myocardial CTP and rest CTP + coronary CTA. Invasive FFR was performed during ICA when clinically indicated. The diagnostic rate and diagnostic accuracy of coronary CTA, CTP, and coronary CTA + CTP were evaluated in stent-, territory-, and patient-based analyses.

RESULTS: In the 150 enrolled patients (132 men; mean age 65.1 ± 9.1 years), the CTP diagnostic rate was significantly higher than that of coronary CTA in all analyses (territory based [96.7% vs. 91.1%; p < 0.0001] and patient based [96% vs. 68%; p < 0.0001]). When ICA was used as gold standard, CTP diagnostic accuracy was significantly higher than that of coronary CTA in all analyses (territory based [92.1% vs. 85.5%, p < 0.03] and patient based [86.7% vs. 76.7%, p < 0.03]). The concordant coronary CTA + CTP assessment exhibited the highest diagnostic accuracy values versus ICA (95.8% in the territory-based analysis). The diagnostic accuracy of CTP was significantly higher than that of coronary CTA (75% vs. 30.5%; p < 0.001). The radiation exposure of coronary CTA + CTP was 4.15 ± 1.5 mSv.

CONCLUSIONS: In patients with coronary stents, CTP significantly improved the diagnostic rate and accuracy of coronary CTA alone compared with both ICA and invasive FFR as gold standard.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Andreini D, Mushtaq S, Pontone G, et al. CT Perfusion Versus Coronary CT Angiography in Patients With Suspected In-Stent Restenosis or CAD Progression. JACC Cardiovasc Imaging. 2019. PMID: 31422127. doi:10.1016/j.jcmg.2019.05.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。