瓣膜性和/或非瓣膜性主动脉病变可干扰肾动脉狭窄的超声诊断
研究纳入226例接受完整肾动脉狭窄筛查方案的患者,发现狭窄肾AImax为6.2±2.9 s-1、非狭窄肾为13.4±3.5 s-1;以CT或MR血管造影(显著狭窄≥50%)为基准,超声敏感度97%、特异度94%、阴性预测值99%、阳性预测值55%;主动脉瓣狭窄或主动脉弓扩张是非狭窄肾AImax假性降低(≤9.0 s-1)的唯一显著预测因子。
要点
- 肾叶间动脉AImax在狭窄肾为6.2±2.9 s-1、非狭窄肾为13.4±3.5 s-1,可辅助筛查肾动脉狭窄。
- 超声诊断显著肾动脉狭窄(≥50%)敏感度97%、特异度94%,阴性预测值99%、阳性预测值55%。
- 非狭窄肾AImax≤9.0 s-1时,应警惕主动脉瓣狭窄或主动脉弓扩张所致假阳性。
核心结论
- 主动脉瓣膜性和非瓣膜性病变可作为近端阻力,衰减肾实质动脉循环的多普勒血流参数,从而模仿外周血管区域的局灶性阻力。
研究设计与样本
- 研究纳入226例接受完整肾动脉狭窄筛查方案的患者,以肾CT或MR血管造影(显著狭窄 cutoff ≥50%)为参考基准。
- AImax定义为收缩早期血流波形的最大加速度除以峰值收缩速度。
- 主动脉病变(主动脉瓣狭窄或主动脉弓扩张)通过超声心动图评估。
关键影像表现/征象
- 狭窄肾AImax为6.2±2.9 s-1,非狭窄肾AImax为13.4±3.5 s-1(均值±标准差)。
诊断标准与关键数值
- 以CT或MR血管造影显著肾动脉狭窄(≥50%)为基准,超声诊断敏感度97%、特异度94%、阴性预测值99%、阳性预测值55%。
- 非狭窄肾AImax cutoff ≤9.0 s-1用于定义意外低值。
- 逻辑回归显示主动脉病变(主动脉瓣狭窄或主动脉弓扩张)是假阳性病例的唯一显著预测因子(Χ2=33.8,p<0.0001)。
临床应用与阅片要点
- 肾叶间动脉AImax降低(≤9.0 s-1)而肾动脉无显著狭窄时,需考虑主动脉瓣狭窄或主动脉弓扩张作为近端阻力来源。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Renal artery stenosis (RAS) has been shown to cause a reduction in the index of maximal systolic acceleration (AImax: the maximal acceleration of flow waveform in early systole divided by the peak systolic velocity) of blood in the renal interlobar arteries, caused by local dampening of the pulse wave. In previous studies, AImax demonstrated diagnostic accuracy in terms of negative predictive value, which is useful for screening, but had a relatively low specificity. We hypothesized that an upstream focal resistance, such as an aortic stenosis or aneurysm, could act in the same way as RAS, thus generating false positives in non-stenotic kidneys. We studied 226 patients who underwent a complete protocol for RAS screening. AImax was 6.2 ± 2.9 s-1 and 13.4 ± 3.5 s-1 (mean ± standard deviation) in stenotic and non-stenotic kidneys, respectively. Diagnostic accuracy of ultrasonography with respect to the benchmark of renal computed tomography or magnetic resonance angiography (significant RAS cutoff ≥50%) resulted in 97% sensitivity, 94% specificity and a negative and positive predictive value of 99% and 55%, respectively. Using logistic regression for unexpectedly low AImax in non-stenotic kidneys (AImax cutoff ≤ 9.0 s-1), aortic pathology, such as aortic valve stenosis or aortic arch dilation (as assessed by echocardiography), was found to be the only significant predictor (Χ2 = 33.8, p < 0.0001) of false positive cases compared with clinical and hemodynamic variables. We concluded that the aortic valvular and non-valvular pathology can act as a proximal resistance that can attenuate the Doppler flowmetric parameters, which explore the flow waveform in the renal parenchymal arterial circulation, thus mimicking the presence of a focal resistance in the peripheral vascular region explored.
引用
- Bardelli M, Cavressi M, Furlanis G, et al. Valvular and/or Non-valvular Aortic Pathology Can Bias the Ultrasonographic Diagnosis of Renal Artery Stenosis. Ultrasound Med Biol. 2019. PMID: 31439362. doi:10.1016/j.ultrasmedbio.2019.07.414
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。