文献速递心血管外周血管DSA

冠状动脉疾病患者的血管内偏振测量

Intravascular Polarimetry in Patients With Coronary Artery Disease.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-08-14

这项首次人体预试验纳入30例患者(急性冠脉综合征12例、稳定型心绞痛18例),用偏振敏感光学频域成像评估342个冠状动脉横截面的偏振特性。结果显示双折射和去偏振在不同斑块类型间有统计学显著差异;急性冠脉综合征病变及破裂纤维帽的双折射低于稳定型心绞痛病变。

要点

  • 偏振敏感光学频域成像可定量测量冠状动脉组织的双折射与去偏振。
  • 双折射与去偏振在不同斑块类型间存在统计学显著差异(两者 P<0.001)。
  • 急性冠脉综合征病变及破裂纤维帽的双折射低于稳定型心绞痛病变(P<0.01)。

核心结论

  • 血管内偏振测量提供定量指标,有助于表征冠状动脉组织,并可能为患者冠状动脉粥样硬化病变提供更精细的见解。

研究设计与样本

  • 首次人体预试验,纳入30例接受偏振敏感光学频域成像的患者(急性冠脉综合征12例、稳定型心绞痛18例),沿所有成像冠状动脉均匀选取342个横截面按常规光学频域成像分为7类斑块,并对244个斑块纤维帽横截面进行分析。

关键影像表现/征象

  • 双折射与去偏振的中位数在7类斑块间差异有统计学意义(两者 P<0.001,单因素方差分析)。
  • 去偏振在各类斑块间差异显著(P<0.05),但正常动脉与纤维斑块之间、纤维脂肪斑块与纤维钙化斑块之间除外。
  • 急性冠脉综合征病变的纤维帽及破裂纤维帽的双折射低于稳定型心绞痛病变的纤维帽(P<0.01)。

诊断标准与关键数值

  • 斑块分类依据常规光学频域成像分为7类。
  • 纤维帽双折射与临床表现及巨噬细胞聚集相关,巨噬细胞聚集采用归一化标准差评估。

局限性

  • 本文为首次人体预试验,样本量为30例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aims of this first-in-human pilot study of intravascular polarimetry were to investigate polarization properties of coronary plaques in patients and to examine the relationship of these features with established structural characteristics available to conventional optical frequency domain imaging (OFDI) and with clinical presentation.

BACKGROUND: Polarization-sensitive OFDI measures birefringence and depolarization of tissue together with conventional cross-sectional optical frequency domain images of subsurface microstructure.

METHODS: Thirty patients undergoing polarization-sensitive OFDI (acute coronary syndrome, n = 12; stable angina pectoris, n = 18) participated in this study. Three hundred forty-two cross-sectional images evenly distributed along all imaged coronary arteries were classified into 1 of 7 plaque categories according to conventional OFDI. Polarization features averaged over the entire intimal area of each cross section were compared among plaque types and with structural parameters. Furthermore, the polarization properties in cross sections (n = 244) of the fibrous caps of acute coronary syndrome and stable angina pectoris culprit lesions were assessed and compared with structural features using a generalized linear model.

RESULTS: The median birefringence and depolarization showed statistically significant differences among plaque types (p < 0.001 for both, one-way analysis of variance). Depolarization differed significantly among individual plaque types (p < 0.05), except between normal arteries and fibrous plaques and between fibrofatty and fibrocalcified plaques. Caps of acute coronary syndrome lesions and ruptured caps exhibited lower birefringence than caps of stable angina pectoris lesions (p < 0.01). In addition to clinical presentation, cap birefringence was also associated with macrophage accumulation as assessed using normalized SD.

CONCLUSIONS: Intravascular polarimetry provides quantitative metrics that help characterize coronary arterial tissues and may offer refined insight into coronary arterial atherosclerotic lesions in patients.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Otsuka K, Villiger M, Karanasos A, et al. Intravascular Polarimetry in Patients With Coronary Artery Disease. JACC Cardiovasc Imaging. 2019. PMID: 31422135. doi:10.1016/j.jcmg.2019.06.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。