先进虚拟单能低keV图像显示肺门淋巴结用于肺癌术前评估的可见性
研究纳入50例肺癌术前患者,行双能增强CT并在注射对比剂后20秒和60秒重建5种图像,比较肺门淋巴结与主肺动脉/肺静脉的CT值对比。结果显示60秒延迟期40keV图像在单一系列图像中评估肺门淋巴结似乎最有价值。
要点
- 60秒延迟期40keV图像评估肺门淋巴结的PA-LN对比度仅次于20秒120kV图像。
- 60秒延迟期40keV与50keV图像的PA-LN和PV-LN对比度显著高于60秒100kV图像。
- 延迟期图像的上腔静脉伪影低于20秒120kV图像。
核心结论
- 作者认为,若用单一系列图像评估肺门淋巴结,延迟60秒期的先进虚拟单能40keV成像似乎最有价值。
研究设计与样本
- 研究纳入50例肺癌术前评估患者(32例男性、18例女性,平均年龄69岁),行双能增强CT,于注射对比剂后20秒和60秒采集。
- 重建5种图像:A为20秒/120kV,B为60秒/40keV,C为60秒/50keV,D为60秒/120kV,E为60秒/100kV。
- 测量双侧主肺动脉、肺静脉和肺门淋巴结的CT值,并评估上腔静脉伪影。
关键影像表现/征象
- 平均PA-LN对比度(HU):A组415、B组299、C组180、D组80、E组100。
- B组PA-LN对比度仅次于A组,居第二位。
- 平均PV-LN对比度(HU):A组306、B组287、C组177、D组78、E组99。
- A组与B组间PV-LN对比度无显著差异。
- B组和C组的PA-LN及PV-LN对比度均显著高于E组。
临床应用与阅片要点
- 延迟60秒期40keV虚拟单能图像可在单一系列图像中兼顾肺门淋巴结与肿瘤的评估,并减少上腔静脉致密对比剂所致条纹伪影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of our study was to evaluate the visibility of the hilar lymph nodes (LNs) using advanced virtual monoenergetic low-keV images compared with early-phase contrast-enhanced CT.
METHODS: Dual energy contrast-enhanced CT was performed for pre-operative evaluation of lung cancer at 20 and 60 s after administration of contrast media in 50 patients (32 males and 18 females; mean age, 69 years). Five kinds of images (A: 20 s/120 kV; B: 60 s/40 keV; C: 60 s/50 keV; D: 60 s/120 kV; E: 60 s/100 kV) were reconstructed. We measured the CT number of the bilateral main pulmonary arteries (PAs), pulmonary veins (PVs) and hilar LNs, and evaluated the differences in CT number (Hounsfield units, HUs) between the PA/PV and LNs (PA-LN and PV-LN contrast). Artifacts from the superior vena cava (SVC) were also evaluated.
RESULTS: The mean PA-LN contrast (HU) was 415 in image group A, 299 in B, 180 in C, 80 in D, and 100 in E. The mean PV-LN contrasts in each group were 306, 287, 177, 78, and 99, respectively. Image group B showed the second highest PA-LN contrast following image group A. There was no significant difference in the PV-LN contrast between image groups A and B. The PA-LN and PV-LN contrasts of image groups B and C were significantly higher than those of E. SVC artifacts were lower in the delayed-phase images (Group B-E) than in Group A.
CONCLUSION: To evaluate the hilar LNs with a single image series, advanced virtual monoenergetic 40-keV imaging at the delayed 60-s phase seems to be the most valuable.
ADVANCES IN KNOWLEDGE: Advanced virtual monoenergetic image is useful for evaluation of both hilar LNs and tumors in the delayed phase without artifact derived from the streak artifact from dense contrast media in the SVC.
引用
- Sekiguchi T, Ozawa Y, Hara M, et al. Visibility of the hilar lymph nodes using advanced virtual monoenergetic low-keV images for preoperative evaluation of lung cancer. Br J Radiol. 2019. PMID: 31430185. doi:10.1259/bjr.20180734