大脑中动脉斑块为何被对比剂强化?基于大脑中动脉狭窄硅胶模型的体模研究
本研究回顾性分析2017年1月至2018年1月急性卒中症状患者黑血对比增强T1加权成像,并按脑血管造影分为大脑中动脉闭塞组(19例)与狭窄组(22例),同时制作4种狭窄程度(狭窄面积0.8、1.0、1.2、1.4 mm,管腔3 mm)的硅胶模型于注药后5分钟行黑血对比增强T1加权成像,结果显示硅胶模型与患者组的斑块及管腔对比强化信号强度比相似(硅胶模型31.0±11.2、闭塞组27.6±19.6、狭窄组22.8±9.8),提示大脑中动脉斑块的对比强化可能部分与对比剂滞留有关。
要点
- 硅胶狭窄模型在注药后5分钟出现管腔内对比剂滞留所致的强化。
- 硅胶模型、大脑中动脉闭塞组与狭窄组的斑块及管腔信号强度比相似。
- 大脑中动脉斑块的对比强化可能部分与对比剂滞留有关。
核心结论
- 硅胶狭窄大脑中动脉模型以对比剂滞留导致的管腔强化为特征,大脑中动脉斑块的对比强化表现可能部分与对比剂滞留有关。
研究设计与样本
- 回顾性研究,纳入2017年1月至2018年1月急性卒中症状患者,按脑血管造影分为大脑中动脉闭塞19例与狭窄22例,并制作4种狭窄面积(0.8、1.0、1.2、1.4 mm,管腔3 mm)的硅胶模型,行黑血对比增强T1加权成像,模型于注药后5分钟成像。
关键影像表现/征象
- 硅胶模型狭窄处管腔出现对比强化,作者将其归因于对比剂滞留。
- 斑块与管腔的对比强化信号强度比在硅胶模型为31.0±11.2、大脑中动脉闭塞组为27.6±19.6、狭窄组为22.8±9.8。
- 硅胶模型的对比强化见于狭窄面积0.8 mm(74%)和1.0 mm(66.7%)者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The pathophysiologic mechanisms of contrast enhancement (CE) of middle cerebral artery (MCA) plaque remain unclear since histologic and imaging findings have never been compared. The purpose of this study was to assess the pattern of CE between patients with MCA stenosis or occlusion and in an MCA stenotic silicone model.
METHODS: We retrospectively reviewed black blood (BB) contrast-enhanced T1-weighted (CE-T1W) imaging of patients who presented with acute stroke symptoms between January 2017 and January 2018. We subdivided the enrolled subjects according to whether the cerebral angiography findings suggested stenosis or occlusion. Silicone models were made with 4 degrees of MCA stenosis (stenotic area: 0.8 mm, 1.0 mm, 1.2 mm, and 1.4 mm) with a 3-mm lumen. BB CE-T1W imaging on silicone models with stenosis was obtained 5 min after contrast injection.
RESULTS: During the period of this study, 19 patients with complete MCA occlusion and 22 with MCA stenosis, as shown by the cerebral angiography, were enrolled in this study. The CE of the silicone models with stenosis were 0.8 (74%) mm and 1.0 (66.7%) mm. The SI ratios of the CE of the plaque and the lumen were similar between the silicone models and the MCA stenosis/occlusion groups (silicone models: 31.0 ± 11.2; MCA occlusion: 27.6 ± 19.6; MCA stenosis: 22.8 ± 9.8).
CONCLUSION: The silicone stenotic MCA model was characterized by luminal enhancement through contrast stagnation. The findings of the CE of the MCA plaque may be partially associated with stagnation of the contrast media.
引用
- Kim SK, Kwak HS, Chung GH, et al. Why is middle cerebral artery plaque augmented by contrast media? A phantom study using middle cerebral artery stenotic silicon model. Neuroradiology. 2019. PMID: 31388726. doi:10.1007/s00234-019-02271-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。