文献速递神经MR

DANTE脉冲联合T1加权SPACE序列在脑转移瘤检测中的价值:与MPRAGE成像的比较

Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-08-01

研究纳入71例疑似脑转移瘤患者,比较增强T1加权SPACE联合DANTE脉冲与MPRAGE序列检测脑转移瘤的诊断效能。SPACE with DANTE显示更多<5 mm强化病灶,且品质因数、敏感度更高,阅读时间更短,病灶-脑实质对比噪声比更高,但白质/灰质对比噪声比更低。结论认为与MPRAGE相比,SPACE with DANTE显著提高脑转移瘤的检测。

要点

  • SPACE with DANTE检测<5 mm强化病灶数多于MPRAGE,两位观察者均显著。
  • SPACE with DANTE的品质因数和敏感度均显著高于MPRAGE,阅读时间更短。
  • SPACE with DANTE病灶/脑实质CNR显著更高,但白质/灰质CNR显著更低。

核心结论

  • 与MPRAGE相比,SPACE with DANTE显著提高脑转移瘤的检测。

研究设计与样本

  • 纳入71例疑似转移性病变且接受增强SPACE with DANTE和MPRAGE序列检查的患者,由两位神经放射学家确定强化病灶数目,评估品质因数、敏感度、阳性预测值、观察者间一致性和阅读时间,并评估病灶/脑实质及白质/灰质对比噪声比。

关键影像表现/征象

  • SPACE with DANTE显示更多<5 mm强化病灶:观察者一328个 vs MPRAGE 175个,观察者二324个 vs MPRAGE 150个。
  • SPACE with DANTE的病灶/脑实质对比噪声比均值52.3 ± 43.1,显著高于MPRAGE的17.5 ± 19.3(P ≤ .0001)。
  • SPACE with DANTE的白质/灰质对比噪声比均值-0.65 ± 1.39,显著低于MPRAGE的3.08 ± 1.39(P ≤ .0001)。

诊断标准与关键数值

  • SPACE with DANTE检测<5 mm强化病灶数:观察者一328个 vs MPRAGE 175个(P < 0.001),观察者二324个 vs MPRAGE 150个(P ≤ .0001)。
  • SPACE with DANTE的品质因数和敏感度均显著高于MPRAGE,阅读时间显著短于MPRAGE(两位观察者均如此)。
  • 病灶/脑实质对比噪声比:SPACE with DANTE 52.3 ± 43.1 vs MPRAGE 17.5 ± 19.3(P ≤ .0001);白质/灰质对比噪声比:SPACE with DANTE -0.65 ± 1.39 vs MPRAGE 3.08 ± 1.39(P ≤ .0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) with the delay alternating with nutation for tailored excitation (DANTE) pulse could suppress the blood flow signal and provide a higher contrast-to-noise ratio of enhancing lesion-to-brain parenchyma than the MPRAGE sequence. The purpose of our study was to evaluate the usefulness of SPACE with DANTE compared with MPRAGE for detecting brain metastases.

MATERIALS AND METHODS: Seventy-one patients who underwent contrast-enhanced SPACE with DANTE and MPRAGE sequences and who were suspected of having metastatic lesions were included. Two neuroradiologists determined the number of enhancing lesions, and diagnostic performance was evaluated using figure of merit, sensitivity, positive predictive value, interobserver agreement, and reading time. Contrast-to-noise ratiolesion/parenchyma and contrast-to-noise ratiowhite matter/gray matter were also assessed.

RESULTS: SPACE with DANTE (observer one, 328; observer two, 324) revealed significantly more small (<5 mm) enhancing lesions than MPRAGE (observer one, 175; observer two, 150) (P < 0.001 for observer 1, P ≤ .0001 for observer 2). Furthermore, SPACE with DANTE showed significantly higher figure of merit and sensitivity and shorter reading time than MPRAGE for both observers. The mean contrast-to-noise ratiolesion/parenchyma of SPACE with DANTE (52.3 ± 43.1) was significantly higher than that of MPRAGE (17.5 ± 19.3) (P ≤ .0001), but the mean contrast-to-noise ratiowhite matter/gray matter of SPACE with DANTE (-0.65 ± 1.39) was significantly lower than that of MPRAGE (3.08 ± 1.39) (P ≤ .0001).

CONCLUSIONS: Compared with MPRAGE, SPACE with DANTE significantly improves the detection of brain metastases.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Kim D, Heo YJ, Jeong HW, et al. Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging. AJNR Am J Neuroradiol. 2019. PMID: 31371358. doi:10.3174/ajnr.A6158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。