文献速递神经外周血管MR

非增强颈动脉MRA:新型非门控径向静息间期层面选择MRA在1.5T的临床评估

Non-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5T.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-08-08

这项前瞻性研究在31例临床怀疑颈动脉狭窄的患者中,比较非门控非增强径向静息间期层面选择MRA与传统对比增强MRA的诊断效能,发现前者静脉污染更少、动脉段显示质量略低,但狭窄分级的敏感度85.7%、特异度90.0%,作者认为可作为对比增强MRA的临床替代。

要点

  • 非门控QISS MRA在1.5T检测颈动脉狭窄的敏感度85.7%、特异度90.0%。
  • QISS MRA静脉污染评为「无」者占84.9%,对比增强MRA仅占8.1%(P<.0001)。
  • QISS MRA动脉段显示良好至优秀者占40.2%,对比增强MRA占52.2%(P<.0001)。

核心结论

  • 非门控静息间期层面选择MRA可在1.5T临床用作对比增强MRA的替代,颈动脉狭窄检测的图像质量与诊断准确度无显著差异。

研究设计与样本

  • 前瞻性研究纳入31例连续患者(中位年龄68.8岁,19例男性),均行非门控非增强径向静息间期层面选择MRA与对比增强MRA两种脉冲序列。
  • 将颈部动脉系统分为35个段(左右两侧),由3名盲法阅片者分别评估。
  • 采用有序评分系统评估动脉段图像质量与颈动脉狭窄分级。

关键影像表现/征象

  • 静息间期层面选择MRA总体静脉污染被所有阅片者评为「无」者占84.9%,对比增强MRA占8.1%(P<.0001)。
  • 动脉段可视化质量评为良好至优秀者,静息间期层面选择MRA占40.2%,对比增强MRA占52.2%(P<.0001)。

诊断标准与关键数值

  • 非门控静息间期层面选择MRA对狭窄分级的总体敏感度为85.7%、特异度为90.0%。
  • 图像质量与狭窄分级均采用有序评分系统评估,由3名盲法阅片者独立完成。

临床应用与阅片要点

  • 在临床怀疑颈动脉狭窄且需避免钆对比剂时,非门控静息间期层面选择MRA可作为对比增强MRA的替代选择。
  • 阅片时注意该序列静脉污染更少,但动脉段可视化质量良好至优秀的比例低于对比增强MRA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Non-contrast-enhanced MRA techniques have experienced a renaissance due to the known correlation between the use of gadolinium-based contrast agents and the development of nephrogenic systemic fibrosis and the deposition of gadolinium in some brain regions. The purpose of this study was to assess the diagnostic performance of ungated non-contrast-enhanced radial quiescent-interval slice-selective MRA of the extracranial supra-aortic arteries in comparison with conventional contrast-enhanced MRA in patients with clinical suspicion of carotid stenosis.

MATERIALS AND METHODS: In this prospective study, both MRA pulse sequences were performed in 31 consecutive patients (median age, 68.8 years; 19 men). For the evaluation, the cervical arterial system was divided into 35 segments (right and left side). Three blinded reviewers separately evaluated these segments. An ordinal scoring system was used to assess the image quality of arterial segments and the stenosis grading of carotid arteries.

RESULTS: Overall venous contamination in quiescent-interval slice-selective MRA was rated as "none" by all readers in 84.9% of cases and in 8.1% of cases in contrast-enhanced MRA (P < .0001). The visualization quality of arterial segments was considered good to excellent in 40.2% for the quiescent-interval slice-selective MRA and in 52.2% for the contrast-enhanced MRA (P < .0001). The diagnostic accuracy of ungated quiescent-interval slice-selective MRA concerning the stenosis grading showed a total sensitivity and specificity of 85.7% and 90.0%, respectively.

CONCLUSIONS: Ungated quiescent-interval slice-selective MRA can be used clinically as an alternative to contrast-enhanced MRA without a significantly different image quality or diagnostic accuracy for the detection of carotid stenosis at 1.5T.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Peters S, Huhndorf M, Jensen-Kondering U, et al. Non-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5T. AJNR Am J Neuroradiol. 2019. PMID: 31395666. doi:10.3174/ajnr.A6171

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。