压缩感知二维磁共振波谱成像在儿童脑中的应用
本研究回顾性评估20例儿童脑部常规检查中压缩感知磁共振波谱成像的扫描时间缩短可行性,对数据集进行2至10倍回顾性欠采样并重建,结果显示50%至80%欠采样下重建保真度高,均方根误差不超过3%,加速因子达5倍时代谢物强度与全采样参考数据集无统计学显著差异且相关性高。
要点
- 压缩感知波谱成像在50%至80%欠采样下重建保真度高,任何数据集的均方根误差不超过3%。
- 加速因子达5倍时,基于体素的代谢物强度和比值与全采样参考数据集无统计学显著差异。
- 压缩感知波谱成像有潜力缩短儿童磁共振波谱成像扫描时间,信息损失可忽略。
核心结论
- 压缩感知磁共振波谱成像有潜力缩短儿童患者的磁共振波谱成像扫描时间,且信息损失可忽略。
研究设计与样本
- 回顾性评估压缩感知重建在20例儿童患者(11男9女,平均年龄5.4±4.5岁,年龄范围3天至16岁)的磁共振波谱成像数据集中的应用;对数据集进行回顾性欠采样以模拟2、3、4、5、7和10倍加速,随后在MATLAB中重建;以全采样参考数据集为参照,采用双尾配对t检验和线性回归分析比较各加速下的压缩感知重建。
诊断标准与关键数值
- 在50%至80%欠采样下压缩感知磁共振波谱成像重建保持高保真度,任何数据集的均方根误差不超过3%;基于体素的代谢物强度和比值与全采样参考数据集相比无统计学显著差异,平均代谢物强度在加速因子达5倍时与全采样参考数据集高度相关;评估的代谢物包括N-乙酰天冬氨酸、肌酸、胆碱和乳酸(适用时)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Magnetic resonance spectroscopic imaging helps to determine abnormal brain tissue conditions by evaluating metabolite concentrations. Although a powerful technique, it is underutilized in routine clinical studies because of its long scan times.
OBJECTIVE: In this study, we evaluated the feasibility of scan time reduction in metabolic imaging using compressed-sensing-based MR spectroscopic imaging in pediatric patients undergoing routine brain exams.
MATERIALS AND METHODS: We retrospectively evaluated compressed-sensing reconstructions in MR spectroscopic imaging datasets from 20 pediatric patients (11 males, 9 females; average age: 5.4±4.5 years; age range: 3 days to 16 years). We performed retrospective under-sampling of the MR spectroscopic imaging datasets to simulate accelerations of 2-, 3-, 4-, 5-, 7- and 10-fold, with subsequent reconstructions in MATLAB. Metabolite maps of N-acetylaspartate, creatine, choline and lactate (where applicable) were quantitatively evaluated in terms of the root-mean-square error (RMSE), peak amplitudes and total scan time. We used the two-tailed paired t-test along with linear regression analysis to statistically compare the compressed-sensing reconstructions at each acceleration with the fully sampled reference dataset.
RESULTS: High fidelity was maintained in the compressed-sensing MR spectroscopic imaging reconstructions from 50% to 80% under-sampling, with the RMSE not exceeding 3% in any dataset. Metabolite intensities and ratios evaluated on a voxel-by-voxel basis showed no statistically significant differences and mean metabolite intensities showed high correlation compared to the fully sampled reference dataset up to an acceleration factor of 5.
CONCLUSION: Compressed-sensing MR spectroscopic imaging has the potential to reduce MR spectroscopic imaging scan times for pediatric patients, with negligible information loss.
引用
- Vidya Shankar R, Hu HH, Bikkamane Jayadev N, et al. 2-D magnetic resonance spectroscopic imaging of the pediatric brain using compressed sensing. Pediatr Radiol. 2019. PMID: 31463513. doi:10.1007/s00247-019-04495-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。