文献速递神经技术与安全MR

伪影校正对评估钆脑沉积的MRI信号强度比的影响

Influence of Artifact Corrections on MRI Signal Intensity Ratios for Assessment of Gadolinium Brain Retention.
PubMed 文献 · Acad Radiol · 2019-08-26

前瞻性研究纳入76例2007至2017年间接受5次及以上钆布醇增强扫描的受试者及25例无钆对比剂应用史对照,比较有无血流伪影补偿(FAC)和强度不均匀性校正(IIC)对齿状核-脑桥及苍白球-丘脑信号强度比的影响。应用IIC算法对脑核团信号强度比有显著影响。

要点

  • 应用FAC后因血流伪影被排除于齿状核-脑桥信号强度比最终分析的比例降低(15% vs 46%,p < 0.001)。
  • 无IIC时研究组与对照组齿状核-脑桥比值存在差异(p = 0.004),同一序列加IIC重建后未见差异(p = 0.29)。
  • 苍白球-丘脑比值在研究组与对照组间未见差异。

核心结论

  • 应用IIC算法对用于评估钆脑沉积的脑核团信号强度比有显著影响。

研究设计与样本

  • 前瞻性研究纳入76例2007至2017年间接受5次及以上钆布醇增强扫描的受试者,并设25例无钆对比剂应用史对照。
  • 所有受试者行非增强脑MRI,包括两个有和无FAC的T1w自旋回波序列,两个序列分别以有和无IIC重建。
  • 评估图像血流伪影并计算信号强度比。

诊断标准与关键数值

  • 应用FAC时因血流伪影被排除于齿状核-脑桥信号强度比最终分析的受试者比例低于无FAC时(15% vs 46%,p < 0.001)。
  • 无IIC重建时研究组与对照组齿状核-脑桥比值存在差异(p = 0.004)。
  • 同一序列以IIC重建时研究组与对照组齿状核-脑桥比值未见差异(p = 0.29)。
  • 苍白球-丘脑比值在研究组与对照组间未见差异。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Differences in brain signal intensity ratios (SIRs) of deep brain nuclei in T1-weighted (T1w) magnetic resonance images were reported as an indicator of gadolinium brain retention. Variable methods of image reconstruction and inhomogeneity correction for T1w images exist, which might affect the accuracy of SIRs. The aim of our prospective study was to investigate the effect of flow artifact compensation (FAC) and intensity inhomogeneity correction (IIC) on the dentate nucleus-to-pons and globus pallidus-to-thalamus SIRs in study participants who had previously received multiple doses of gadobutrol.

MATERIALS AND METHODS: This study included 76 participants who received five or more gadobutrol-enhanced scans between 2007 and 2017. A control group of 25 participants without gadolinium-based contrast agent application in their patient history was included for comparison. Unenhanced brain magnetic resonance imaging including two T1w spin-echo sequences with and without FAC was performed in all participants. Both sequences were reconstructed with and without IIC. Images were assessed for flow artifacts and SIRs were calculated.

RESULTS: Using FAC, a lower proportion of participants had to be excluded from the final analysis of dentate nucleus-to-pons SIR due to flow artifacts (15% versus 46%, p < 0.001). Without IIC, a difference was found between the study and the control group for the dentate nucleus-to-pons ratio (p = 0.004), but not for the same sequence reconstructed with IIC (p = 0.29). For the globus pallidus-to-thalamus ratio, no difference was found between the study and control group.

CONCLUSION: The application of an IIC algorithm has significant impact on brain nuclei SIRs for the assessment of gadolinium brain retention.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Saake M, Hepp T, Schmidle A, et al. Influence of Artifact Corrections on MRI Signal Intensity Ratios for Assessment of Gadolinium Brain Retention. Acad Radiol. 2019. PMID: 31466889. doi:10.1016/j.acra.2019.07.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。