文献速递神经技术与安全US

脑组织损伤与被动空化成像定量的惯性空化剂量之间的相关性

Correlation Between Brain Tissue Damage and Inertial Cavitation Dose Quantified Using Passive Cavitation Imaging.
PubMed 文献 · Ultrasound Med Biol · 2019-08-02

本研究用被动空化成像(PCI)定量聚焦超声联合微泡在小鼠脑中产生的惯性空化剂量,并与组织学损伤程度对照,发现惯性空化剂量与组织学级损伤范围呈线性相关,提示PCI可用于预测聚焦超声诱导空化相关的组织学级损伤。

要点

  • 被动空化成像(PCI)可定量聚焦超声联合微泡产生的惯性空化剂量。
  • 惯性空化剂量与组织学级脑组织损伤范围呈线性相关。
  • PCI可能用于预测聚焦超声诱导空化相关的组织学级损伤。

核心结论

  • 基于PCI定量的惯性空化剂量与组织学级组织损伤范围呈线性相关。
  • 本研究提示PCI可用于预测聚焦超声诱导空化相关的组织学级组织损伤。

研究设计与样本

  • 研究类型为动物实验,对象为小鼠。
  • 使用超声图像引导的聚焦超声系统,由单元件聚焦超声换能器(1.5 MHz)与同轴对齐的128阵元线性超声成像阵列组成。
  • 小鼠在全身注射微泡条件下接受不同峰值负压(0.5 MPa、1.1 MPa、4.0 MPa和6.5 MPa)的聚焦超声辐照。
  • 成像阵列被动检测聚焦超声激活微泡的声发射,采集预波束形成通道数据并用频域延迟、求和与积分算法离线处理生成惯性空化图。
  • 所有小鼠在聚焦超声处理后处死,取脑组织行苏木精-伊红染色作为组织学参考标准。

关键影像表现/征象

  • 惯性空化图揭示了不同压力水平下聚焦超声处理过程中微泡行为的动态变化。
  • 基于PCI定量的惯性空化剂量与组织学级组织损伤范围呈线性相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Focused ultrasound (FUS)-induced cavitation-mediated brain therapies have become emerging therapeutic modalities for neurologic diseases. Cavitation monitoring is essential to ensure the safety of all cavitation-mediated therapeutic techniques as inertial cavitation can be associated with tissue damage. The objective of this study was to reveal the correlation between the inertial cavitation dose, quantified by passive cavitation imaging (PCI), and brain tissue histologic-level damage induced by FUS in combination with microbubbles. An ultrasound image-guided FUS system consisting of a single-element FUS transducer (1.5 MHz) and a co-axially aligned 128-element linear ultrasound imaging array was used to perform FUS treatment of mice. Mice were sonicated by FUS with different peak negative pressures (0.5 MPa, 1.1 MPa, 4.0 MPa and 6.5 MPa) in the presence of systemically injected microbubbles. The acoustic emissions from the FUS-activated microbubbles were passively detected by the imaging array. The pre-beamformed channel data were acquired and processed offline using the frequency-domain delay, sum and integration algorithm to generate inertial cavitation maps. All the mice were sacrificed after the FUS treatment, and their brains were harvested and processed for hematoxylin and eosin staining. The obtained inertial cavitation maps revealed the dynamic changes of microbubble behaviors during FUS treatment at different pressure levels. It was found that the inertial cavitation dose quantified based on PCI had a linear correlation with the scale of histologic-level tissue damage. Findings from this study suggested that PCI can be used to predict histologic-level tissue damage associated with the FUS-induced cavitation.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Xu S, Ye D, Wan L, et al. Correlation Between Brain Tissue Damage and Inertial Cavitation Dose Quantified Using Passive Cavitation Imaging. Ultrasound Med Biol. 2019. PMID: 31378549. doi:10.1016/j.ultrasmedbio.2019.07.004