加速DTI在较低级别胶质瘤分子亚型分类中的应用
本研究纳入41例已知IDH突变和1p/19q联合缺失状态的较低级别胶质瘤患者,术前行DTI检查,利用神经网络DiffNet从仅含3个扩散编码方向的加速DTI子集估算FA,并与常规ADC及FA比较。结果显示ADC、FA及估算FA在IDH野生型与突变型间差异显著,ADC+FA及ADC+估算FA的多变量分类模型较单用ADC提高了IDH突变和1p/19q联合缺失状态的分类效能。
要点
- ADC、FA及DiffNet估算FA在IDH野生型与突变型较低级别胶质瘤间差异有统计学意义。
- ADC+FA分类IDH突变和1p/19q联合缺失的AUC分别为0.90和0.94,优于单用ADC的0.81和0.83。
- ADC+估算FA分类IDH突变和1p/19q联合缺失的AUC均为0.89,提示加速3方向DTI估算FA有附加价值。
核心结论
- 从加速3方向DTI扫描估算的FA在较低级别胶质瘤分子状态分类中具有附加价值。
研究设计与样本
- 研究纳入41例WHO II级和III级较低级别胶质瘤患者,已知IDH突变和1p/19q联合缺失状态,术前行DTI检查;采用常规解剖MRI序列自动勾画全肿瘤体积,除常规ADC和FA重建外,利用神经网络DiffNet从3方向DTI子集计算FA估算值;基于全肿瘤直方图和纹理特征建立多变量分类模型。
诊断标准与关键数值
- ADC在IDH野生型与IDH突变型较低级别胶质瘤间差异显著(P = .008)。
- FA在IDH野生型与IDH突变型较低级别胶质瘤间差异显著(P < .001)。
- 估算FA在IDH野生型与IDH突变型较低级别胶质瘤间差异显著(P < .001)。
- ADC在IDH突变型伴与不伴1p/19q联合缺失的较低级别胶质瘤间差异显著(P < .001)。
- 单用ADC多变量分类预测IDH突变状态的AUC为0.81,预测1p/19q联合缺失状态的AUC为0.83。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Image-based classification of lower-grade glioma molecular subtypes has substantial prognostic value. Diffusion tensor imaging has shown promise in lower-grade glioma subtyping but currently requires lengthy, nonstandard acquisitions. Our goal was to investigate lower-grade glioma classification using a machine learning technique that estimates fractional anisotropy from accelerated diffusion MR imaging scans containing only 3 diffusion-encoding directions.
MATERIALS AND METHODS: Patients with lower-grade gliomas (n = 41) (World Health Organization grades II and III) with known isocitrate dehydrogenase (IDH) mutation and 1p/19q codeletion status were imaged preoperatively with DTI. Whole-tumor volumes were autodelineated using conventional anatomic MR imaging sequences. In addition to conventional ADC and fractional anisotropy reconstructions, fractional anisotropy estimates were computed from 3-direction DTI subsets using DiffNet, a neural network that directly computes fractional anisotropy from raw DTI data. Differences in whole-tumor ADC, fractional anisotropy, and estimated fractional anisotropy were assessed between IDH-wild-type and IDH-mutant lower-grade gliomas with and without 1p/19q codeletion. Multivariate classification models were developed using whole-tumor histogram and texture features from ADC, ADC + fractional anisotropy, and ADC + estimated fractional anisotropy to identify the added value provided by fractional anisotropy and estimated fractional anisotropy.
RESULTS: ADC (P = .008), fractional anisotropy (P < .001), and estimated fractional anisotropy (P < .001) significantly differed between IDH-wild-type and IDH-mutant lower-grade gliomas. ADC (P < .001) significantly differed between IDH-mutant gliomas with and without codeletion. ADC-only multivariate classification predicted IDH mutation status with an area under the curve of 0.81 and codeletion status with an area under the curve of 0.83. Performance improved to area under the curve = 0.90/0.94 for the ADC + fractional anisotropy classification and to area under the curve = 0.89/0.89 for the ADC + estimated fractional anisotropy classification.
CONCLUSIONS: Fractional anisotropy estimates made from accelerated 3-direction DTI scans add value in classifying lower-grade glioma molecular status.
引用
- Aliotta E, Nourzadeh H, Batchala PP, et al. Molecular Subtype Classification in Lower-Grade Glioma with Accelerated DTI. AJNR Am J Neuroradiol. 2019. PMID: 31413006. doi:10.3174/ajnr.A6162
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。