文献速递神经MR

脊髓灰质自动定量:一种新方法

Automatic Spinal Cord Gray Matter Quantification: A Novel Approach.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-08-22

研究纳入24名健康受试者,在3T MR上采用平均磁化反转恢复采集序列扫描颈髓,比较全自动分割算法与2名阅片者手动分割的灰质和白质横截面积测量。自动法重复性高(平均变异系数≤4.77%),与手动参考标准的一致性优良(灰质Dice系数0.86±0.04,白质0.90±0.03)。

要点

  • 自动法测得颈髓灰质平均面积17.20±2.28 mm²,白质72.71±7.55 mm²。
  • 自动法重复性优于手动法(所有平均变异系数≤4.77%,差异均P<.001)。
  • 自动法与手动参考标准一致性优良:灰质Dice 0.86±0.04,白质0.90±0.03。

核心结论

  • 联合平均磁化反转恢复采集序列与全自动后处理分割算法,可准确、可重复地分割脊髓灰质和白质,有望用于纵向灰质结构变化探索及脊髓受累疾病的临床场景。

研究设计与样本

  • 对24名健康受试者(14名女性,平均年龄40±11岁)在3T MR系统上行test-retest扫描,采集48 mm颈髓节段内12层轴位平均磁化反转恢复图像;由2名经验阅片者手动分割灰质和白质,与采用形状先验(针对3D数据修改并加入层间相似性先验)的自动变分分割算法比较。

诊断标准与关键数值

  • 自动法重复性以变异系数评估,所有平均自动变异系数≤4.77%,自动法与手动法差异均P<.001;准确性以Dice相似系数评估,灰质0.86±0.04、白质0.90±0.03;自动法测得灰质平均面积17.20±2.28 mm²、白质平均面积72.71±7.55 mm²。

临床应用与阅片要点

  • 自动法在层内与层间重复性变异系数相近,且在各采集脊髓层面间表现相似。
  • 作者认为该流程有望用于纵向灰质结构变化探索及脊髓受累疾病的临床应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Currently, accurate and reproducible spinal cord GM segmentation remains challenging and a noninvasive broadly accepted reference standard for spinal cord GM measurements is still a matter of ongoing discussion. Our aim was to assess the reproducibility and accuracy of cervical spinal cord GM and WM cross-sectional area measurements using averaged magnetization inversion recovery acquisitions images and a fully-automatic postprocessing segmentation algorithm.

MATERIALS AND METHODS: The cervical spinal cord of 24 healthy subjects (14 women; mean age, 40 ± 11 years) was scanned in a test-retest fashion on a 3T MR imaging system. Twelve axial averaged magnetization inversion recovery acquisitions slices were acquired over a 48-mm cord segment. GM and WM were both manually segmented by 2 experienced readers and compared with an automatic variational segmentation algorithm with a shape prior modified for 3D data with a slice similarity prior. Precision and accuracy of the automatic method were evaluated using coefficients of variation and Dice similarity coefficients.

RESULTS: The mean GM area was 17.20 ± 2.28 mm2 and the mean WM area was 72.71 ± 7.55 mm2 using the automatic method. Reproducibility was high for both methods, while being better for the automatic approach (all mean automatic coefficients of variation, ≤4.77%; all differences, P < .001). The accuracy of the automatic method compared with the manual reference standard was excellent (mean Dice similarity coefficients: 0.86 ± 0.04 for GM and 0.90 ± 0.03 for WM). The automatic approach demonstrated similar coefficients of variation between intra- and intersession reproducibility as well as among all acquired spinal cord slices.

CONCLUSIONS: Our novel approach including the averaged magnetization inversion recovery acquisitions sequence and a fully-automated postprocessing segmentation algorithm demonstrated an accurate and reproducible spinal cord GM and WM segmentation. This pipeline is promising for both the exploration of longitudinal structural GM changes and application in clinical settings in disorders affecting the spinal cord.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。