将锥形束CT纳入疑似桡腕关节骨折的诊断流程:新的诊疗标准?
该前瞻性研究评估在标准影像流程中加入锥形束CT对疑似平片阴性桡腕关节骨折患者的价值。117例患者中50.4%检出骨折,共67处平片隐匿性骨折;锥形束CT敏感度98.3%、特异度100%、准确率99.1%。作者认为锥形束CT应视为这类患者检查的新标准。
要点
- 平片阴性但临床怀疑桡腕关节骨折时,锥形束CT可检出约50%的隐匿性骨折。
- 锥形束CT诊断敏感度98.3%、特异度100%、准确率99.1%,阴性预测值98.3%。
- 锥形束CT辐射剂量低于常规多层CT,可提供比平片更多的诊断信息。
核心结论
- 将锥形束CT纳入标准化诊断流程后,平片阴性但临床持续怀疑桡腕关节骨折的患者骨折检出率为50%;锥形束CT辐射剂量低于常规多层CT,作者认为应将其视为这类患者检查的新标准。
研究设计与样本
- 前瞻性研究评估所有因急性腕痛、初始平片正常而接受锥形束CT检查的患者,共117例;平片未发现骨折但临床仍怀疑骨折者转诊MRI。
关键影像表现/征象
- 117例中50.4%检出骨折,共67处平片隐匿性骨折。
- 1处骨折在MRI上发现而锥形束CT未见。
诊断标准与关键数值
- 锥形束CT诊断骨折的敏感度为98.3%(95%CI,91.1-100%)。
- 特异度为100%(95%CI,93.7-100%)。
- 阳性预测值为100%,阴性预测值为98.3%(95%CI,89.1-100%)。
- 准确率为99.1%(95%CI,95.3-100%)。
临床应用与阅片要点
- 作者认为锥形束CT应视为疑似桡腕关节骨折患者检查的新标准。
- 锥形束CT辐射剂量低于常规多层CT。
- 平片对急性桡腕关节骨折准确率低,且本队列骨折患病率高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.
引用
- Gibney B, Smith M, Moughty A, et al. Incorporating Cone-Beam CT Into the Diagnostic Algorithm for Suspected Radiocarpal Fractures: A New Standard of Care? AJR Am J Roentgenol. 2019. PMID: 31287723. doi:10.2214/AJR.19.21478
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。