动脉自旋标记MRI识别富血供脑膜瘤
回顾性分析34例患者39个脑膜瘤的ASL MRI与DSA资料,比较肿瘤标准化血流量与DSA肿瘤染色。有染色组标准化TBF显著高于无染色组,rater1为4.7±1.1 vs 1.5±1.1,rater2为4.9±5.3 vs 1.5±1.1(p<0.001)。AUC为0.82,阈值2.7时敏感度88%、特异度67%。作者认为ASL MRI有潜力作为无创筛查工具识别富血供脑膜瘤。
要点
- ASL测得的标准化肿瘤血流量在DSA有肿瘤染色的脑膜瘤中显著高于无染色者。
- 标准化TBF阈值2.7识别DSA肿瘤染色的敏感度88%、特异度67%,AUC 0.82。
- ASL MRI可能作为无创筛查工具识别富血供脑膜瘤,作者结论为「shows potential」。
核心结论
- ASL MRI有潜力作为无创筛查工具识别富血供脑膜瘤。
研究设计与样本
- 回顾性研究纳入34例患者39个脑膜瘤,均行ASL MRI和DSA检查,时间范围为2008年1月至2017年1月。
- 两名评估者独立在ASL后处理图像上通过ROI分析计算标准化肿瘤血流量(TBF),并记录DSA上肿瘤染色的有无。
- 采用组内相关系数(ICC)评估评估者间一致性,采用ROC曲线下面积(AUC)评估ASL MRI识别肿瘤染色的性能。
关键影像表现/征象
- DSA上有肿瘤染色的脑膜瘤标准化TBF显著高于无肿瘤染色者(p<0.001)。
- 有肿瘤染色组与无肿瘤染色组的平均标准化TBF分别为:评估者1为4.7±1.1 vs 1.5±1.1,评估者2为4.9±5.3 vs 1.5±1.1。
诊断标准与关键数值
- 两名评估者间ICC为0.91,一致性优秀。
- 以标准化TBF识别DSA肿瘤染色的AUC为0.82(95% CI,0.72-0.91)。
- 标准化TBF切点2.7识别DSA肿瘤染色的敏感度为88%、特异度为67%。
临床应用与阅片要点
- 作者认为ASL MRI有潜力作为无创筛查工具识别富血供脑膜瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Preoperative identification of hypervascular meningiomas can potentially detect those that may benefit from presurgical embolization, which may help to minimize intraoperative blood loss. In this study, we investigate if increased blood flow within meningiomas seen on arterial spin-labeling (ASL) MRI correlates with increased tumor vascularity seen on digital subtraction angiography (DSA). MATERIALS AND METHODS. A retrospective study was performed of 39 meningiomas in 34 patients who underwent ASL MRI and DSA between January 2008 and January 2017. Two raters independently calculated normalized tumor blood flow (TBF) on postprocessed ASL images using ROI analysis. They also recorded the presence or absence of tumor blush on DSA in each case. Interrater agreement was assessed with intraclass correlation coefficient (ICC). Performance of ASL MRI to identify tumor blush was determined with area under the ROC curve (AUC). RESULTS. In 27 female and seven male patients (mean age, 62.8 years), mean normalized TBF for meningiomas with tumor blush on DSA was significantly higher than those without tumor blush (p < 0.001). Mean normalized TBF for the group with tumor blush and the group without tumor blush group was 4.7 ± 1.1 and 1.5 ± 1.1, respectively, for rater 1 and 4.9 ± 5.3 and 1.5 ± 1.1, respectively, for rater 2. ICC was excellent (0.91). AUC for using normalized TBF to identify tumor vascularity on DSA was 0.82 (95% CI, 0.72-0.91), and a normalized TBF cut point of 2.7 yielded 88% sensitivity and 67% specificity. CONCLUSION. ASL MRI shows potential as a noninvasive screening tool for identifying hypervascular meningiomas.
引用
- Mayercik V, Ma M, Holdsworth S, et al. Arterial Spin-Labeling MRI Identifies Hypervascular Meningiomas. AJR Am J Roentgenol. 2019. PMID: 31361532. doi:10.2214/AJR.18.21026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。