儿童克罗恩病MR小肠造影中扩散加权成像与对比增强成像的检测比较及组织病理学对照
研究纳入2015年4月至2018年6月间68例确诊克罗恩病的儿童患者,行MR小肠造影(含DWI与对比增强序列),由两名放射科医生以四点置信度量表对肠段炎症评分并与组织病理学对照。DWI检测活动性小肠炎症的敏感度97.6%、特异度96.1%、准确率97%,对比增强组敏感度83.3%、特异度96.1%、准确率88.2%;DWI敏感度显著优于对比增强成像(p=0.002),特异度相似(p=0.743)。作者认为DWI/ADC应纳入标准MR小肠造影方案,并提示DWI可能替代T1加权增强序列。
要点
- DWI检测活动性小肠炎症敏感度97.6%、准确率97%,高于对比增强成像的敏感度83.3%、准确率88.2%。
- DWI敏感度显著优于对比增强T1加权成像(p=0.002),两者特异度相似(p=0.743)。
- 作者建议将DWI/ADC纳入标准MR小肠造影方案,并提示DWI可能替代T1加权增强序列。
核心结论
- DWI序列检测克罗恩病受累肠段准确率高,敏感度显著优于对比增强T1加权成像(p=0.002)而特异度相似(p=0.743),作者建议将DWI/ADC纳入标准MR小肠造影方案并提示DWI可能替代T1加权增强序列。
研究设计与样本
- 研究纳入2015年4月至2018年6月间68例确诊克罗恩病的儿童患者,行MR小肠造影检查,序列包括冠状位和轴位FISP、T2加权半傅里叶RARE及DWI序列,以及基线冠状位T1加权脂肪饱和超快速GRE序列和随后对比剂增强3D T1加权GRE序列;由两名放射科医生基于壁增厚及DWI和ADC图上的壁信号,以四点置信度量表对每个肠段炎症评分,并与增强后图像及组织病理学对照。
关键影像表现/征象
- DWI评估全部肠段时获41个真阳性、25个真阴性,1例假阳性为15岁男性终末回肠无炎症组织病理学改变,1例假阴性为10岁女性仅有空肠病变。
- 对比增强组获35个真阳性、25个真阴性,1例假阳性与DWI为同一病例。
诊断标准与关键数值
- DWI检测活动性小肠炎症:敏感度97.6%(95%CI 67.7-99.7)、特异度96.1%(95%CI 66.7-98.5)、PPV 97.6%(95%CI 70.8-98.4)、NPV 96.1%(95%CI 64.2-90.6)、准确率97%(95%CI 84.2-97.5)。
- 对比增强T1加权成像检测活动性小肠炎症:敏感度83.3%(95%CI 65.9-86.7)、特异度96.1%(95%CI 68.7-88.9)、PPV 97.2%(95%CI 84.3-98.7)、NPV 78.1%(95%CI 27.9-72.1)、准确率88.2%(95%CI 41.2-85.6)。
- DWI检测活动性炎症的敏感度显著优于对比增强T1加权成像(p=0.002),特异度相似(p=0.743)。
临床应用与阅片要点
- 作者认为应将DWI/ADC纳入标准MR小肠造影方案,并提示DWI可能替代T1加权增强序列。
- 阅片时基于壁增厚及DWI和ADC图上的壁信号对肠段炎症进行评分,并与增强后图像对照。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The purpose of this study was to determine whether MRE performed with diffusion-weighted imaging (DWI) sequences is comparable to contrast-enhanced MRE in the detection of active small-bowel inflammation in pediatric patients with Crohn's disease (CD). We included in our study 68 patients with diagnosis of CD between April 2015 and June 2018 that underwent MRE examination. Examination protocol includes coronal and axial FISP, T2-w half-Fourier RARE and DWI sequences, a baseline coronal T1-w fat-saturated ultrafast (GRE) sequence followed by contrast 3D T1-w GRE. All images were assessed by two radiologists who graded each of bowel segments for the presence of inflammation on a four-point confidence scale on the basis of wall thickening and wall signal on DWI and ADC maps and comparing their results with post-contrast images. When considering all bowel segments, we found 41 true positive and 25 true negative on DWI. One false positive case corresponded to the absence of inflammatory histopathology changes at the level of the terminal ileum in a 15-year-old male, and one false negative case was in a 10-year-old female with only jejunal lesion. The corresponding sensitivity, specificity, PPV, NPV and accuracy were 97.6% (95% CI 67.7-99.7), 96.1% (95% CI 66.7-98.5), 97.6% (95% CI 70.8-98.4), 96.1% (95% CI 64.2-90.6) and 97% (95% CI 84.2-97.5), respectively. Analyzing the gadolinium-enhanced set, 35 true positive and 25 true negative results were found. One false positive case was found, and it was the same as with DWI. The corresponding sensitivity, specificity, PPV, NPV and accuracy were 83.3% (95% CI 65.9-86.7), 96.1% (95% CI 68.7-88.9), 97.2% (95% CI 84.3-98.7), 78.1% (95% CI 27.9-72.1) and 88.2% (95% CI 41.2-85.6), respectively. Sensitivity for the detection of active IBD lesion was significantly better with DWI than with CE-T1-w imaging (p = 0.002), whereas the specificity was similar (p = 0.743). Our study has shown that DWI sequences have a high accuracy in detecting the bowel segment affected by CD. These results emphasize the utility to include the DWI/ADC in standard MR enterography protocols and suggest that DWI could replace T1-weighted post-contrast sequences.
引用
- Masselli G, De Vincentiis C, Aloi M, et al. Detection of Crohn's disease with diffusion images versus contrast-enhanced images in pediatric using MR enterography with histopathological correlation. Radiol Med. 2019. PMID: 31317380. doi:10.1007/s11547-019-01067-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。