发育性髋关节发育不良术中股骨头灌注的超声造影成像:一项可行性研究
本研究为单机构回顾性研究,评估17例发育性髋关节发育不良患儿共20次术中髋关节超声造影检查,并与术后钆增强MRI对比。所有超声造影在复位前后均显示股骨骨骺血流,所有MRI在复位后显示股骨头强化;7例可评估患儿的超声造影与MRI均显示骺板血流。结论认为超声造影是术中评估DDH复位术后血流的可行工具。
要点
- 术中超声造影可在复位前后实时显示股骨骨骺血流,作为术后钆增强MRI的术中替代评估。
- 12例中7例(58.3%)可回顾性评估,其超声造影与MRI均显示股骨骨骺和骺板血流。
- 所有超声造影均见复位前后股骨骨骺血流,所有MRI均见复位后股骨头强化。
核心结论
- 超声造影是术中评估发育性髋关节发育不良复位术后股骨头足够血流的可行工具。
研究设计与样本
- 单机构回顾性研究,经机构审查委员会批准并豁免知情同意,纳入17例发育性髋关节发育不良患儿共20次术中髋关节超声造影,并与术后钆增强MRI对比;由对既往影像和结局设盲的儿科放射科医师分别独立和共识判读。
关键影像表现/征象
- 所有超声造影检查在复位前和复位后均显示股骨骨骺血流。
- 所有MRI检查在复位后均显示股骨头强化。
- 可评估的7例患儿中,超声造影与MRI均显示骺板血流。
临床应用与阅片要点
- 术中超声造影可在复位前后实时评估股骨头灌注,作为术后钆增强MRI的术中替代方法。
- 判读时分别评估复位前与复位后的股骨骨骺血流,并注意骺板血流的显示。
局限性
- 本研究为单机构回顾性研究。
- 17例患儿中仅12例(70.6%)具备复位前超声造影、复位后超声造影和复位后钆增强MRI,其中仅7例(58.3%)可回顾性评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Developmental dysplasia of the hip (DDH) is one of the most common developmental deformities of the lower extremity. Although many children are successfully treated with a brace or harness, some require intraoperative closed or open reduction and spica casting. Surgical reduction is largely successful to relocate the hip; however, iatrogenic avascular necrosis is a major source of morbidity. Recent research showed that postoperative gadolinium-enhanced magnetic resonance imaging (MRI) can depict hip perfusion, which may predict a future incidence of avascular necrosis. As contrast-enhanced ultrasound (CEUS) assesses blood flow in real time, it may be an effective intraoperative alternative to evaluate femoral head perfusion. Here we describe our initial experience regarding the feasibility of intraoperative CEUS of the hip for the assessment of femoral head perfusion before and after DDH reduction.
METHODS: This single-institution retrospective Institutional Review Board-approved study with a waiver of informed consent evaluated intraoperative hip CEUS in children with DDH compared to postoperative contrast-enhanced MRI. Pediatric radiologists, blinded to prior imaging findings and outcomes, reviewed both CEUS and MRI examinations separately and some time from the initial examination both independently and in consensus.
RESULTS: Seventeen patients had 20 intraoperative CEUS examinations. Twelve of 17 (70.6%) had prereduction hip CEUS, postreduction hip CEUS, and postreduction gadolinium-enhanced MRI. Seven of 12 (58.3%) were evaluable retrospectively. All CEUS studies showed blood flow in the femoral epiphysis before and after reduction, and all MRI studies showed femoral head enhancement after reduction. The CEUS and MRI for all 7 patients also showed physeal blood flow.
CONCLUSIONS: Contrast-enhanced ultrasound is a feasible intraoperative tool for assessing adequate blood flow after hip reduction surgery in DDH.
引用
- Back SJ, Chauvin NA, Ntoulia A, et al. Intraoperative Contrast-Enhanced Ultrasound Imaging of Femoral Head Perfusion in Developmental Dysplasia of the Hip: A Feasibility Study. J Ultrasound Med. 2019. PMID: 31334874. doi:10.1002/jum.15097
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。