颈段椎板间硬膜外类固醇注射中注射物扩散范围的横断面CT评估:CT透视引导下的研究
本研究回顾性分析83例CT透视引导下颈段椎板间硬膜外类固醇注射(CILESI),术后行颈椎CT评估注射物在硬膜外间隙及神经孔的扩散范围。结果显示腹侧硬膜外间隙(VES)向头侧平均扩散不足1个节段,神经孔约2个节段;VES扩散在穿刺节段(43%)较其他节段(19.5%)更常见,且同侧神经孔扩散较对侧更常见。
要点
- CT透视引导CILESI后,VES向头侧平均扩散0.6个节段,35%的注射未见VES扩散。
- VES扩散在穿刺节段的发生率(43%)高于其他节段(19.5%)(P < .001)。
- 注射物在神经孔的扩散以同侧为主(P < .001),对侧扩散平均1.9个节段。
核心结论
- 颈段椎板间硬膜外类固醇注射的注射物在腹侧硬膜外间隙向头侧平均扩散不足1个节段,在神经孔约2个节段;VES扩散更常见于穿刺节段及同侧神经孔。
研究设计与样本
- 回顾性分析2016年6月至2017年12月连续83例CT透视引导下CILESI,所有操作使用相同注射物(2 mL皮质类固醇、3 mL对比剂),术后行颈椎CT评估对比剂分布。
关键影像表现/征象
- 术后CT评估对比剂在腹侧硬膜外间隙、背侧硬膜外间隙、同侧神经孔及对侧神经孔的分布。
- VES向头侧平均扩散0.6个节段,对侧神经孔1.9个节段,同侧神经孔2.1个节段,背侧硬膜外间隙3个节段。
- 35%(29/83)的注射在任何节段均未见VES扩散。
诊断标准与关键数值
- VES扩散在穿刺节段的发生率为43%(36/83),在其他节段为19.5%(97/498)(P < .001)。
- 同侧神经孔扩散较对侧更常见(P < .001)。
临床应用与阅片要点
- CT横断面成像可直接显示对比剂在VES的分布,有助于评估针尖位置与疼痛靶点的关系。
- 穿刺节段及同侧神经孔是VES扩散的主要部位,阅片时应重点关注。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Previous studies analyzed contrast agent spread during cervical interlaminar epidural steroid injections (CILESIs) by using planar fluoroscopy and reported wide variance of the rate of spread to the ventral epidural space (VES). Cross-sectional CT allows for direct viewing of contrast agent in the VES, providing improved spread assessment and thereby informing needle placement decisions when targeting pain generators. Purpose To determine the extent of injectate spread at CT fluoroscopy-guided CILESI, with particular attention to the VES and bilateral neuroforamina, by using cross-sectional CT. Materials and Methods This study reviewed 83 consecutive CT fluoroscopy-guided CILESIs at which a postprocedural cervical spine CT was performed (June 2016 to December 2017). All procedures used the same injectate (2 mL corticosteroid, 3 mL contrast agent). Postprocedural CT scans were reviewed for the presence of contrast within the VES, dorsal epidural space, ipsilateral neuroforamen, and contralateral neuroforamen in every cervical interlaminar level. Descriptive data are presented as frequencies or means. McNemar tests or hierarchical logistic models were used to assess associations between covariates and contrast agent spread to particular locations. Results The study cohort included 73 individual patients (59% women; 43 of 73) (mean patient age, 57.6 years ± 11.5 [standard deviation]). Mean number of levels of cranial spread were 0.6 level for VES, 1.9 levels for contralateral neuroforamen, 2.1 levels for ipsilateral neuroforamen, and 3 levels for dorsal epidural space. No VES spread in any level was found with 35% (29 of 83) of injections. VES spread was more likely to occur in the level of needle placement (43%; 36 of 83) than in other interlaminar levels (19.5%; 97 of 498; P < .001). Spread was more likely to occur in the neuroforamen ipsilateral to the needle approach compared with contralateral (P < .001). Conclusion Cervical interlaminar epidural steroid injections have injectate spreads with a mean of less than one level cranially in the ventral epidural space (VES) and approximately two levels in the neuroforamen. VES spread occurs more frequently at the level of needle placement and within the ipsilateral neuroforamen. © RSNA, 2019.
引用
- Amrhein TJ, Bozdogan E, Vekaria S, et al. Cross-sectional CT Assessment of the Extent of Injectate Spread at CT Fluoroscopy-guided Cervical Epidural Interlaminar Steroid Injections. Radiology. 2019. PMID: 31310176. doi:10.1148/radiol.2019182795
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。