文献速递骨肌技术与安全DR

腰椎X线摄影——是时候广泛采用后前位投照了吗?

Lumbar spine radiographs - is it time for widespread adoption of posteroanterior projection?
PubMed 文献 · Br J Radiol · 2019-08-07

比较站立位腰椎X线后前位(PA)与前后位(AP)的辐射剂量和图像质量,并调查英国现行实践。PA较AP有效剂量降低41%(p<0.001),图像质量无差异(p=0.9);调查21名放射科医生,仅1家NHS信托使用PA。作者认为应标准化为PA。

要点

  • 站立位腰椎X线采用PA投照较AP有效剂量降低41%,图像质量无差异。
  • 欧洲指南标准评分显示两种投照图像质量无统计学差异(p=0.9)。
  • 英国多数NHS信托仍使用AP,仅1家使用PA,作者认为应标准化为PA。

核心结论

  • PA腰椎X线摄影降低患者辐射暴露,对图像质量、采集时间或成本无影响,作者认为应标准化为PA。

研究设计与样本

  • 本地评估研究,纳入80例站立位腰椎X线检查的门诊患者(40例AP;40例PA),在恒定KV和焦片距下记录剂量面积乘积,使用PCXMC软件计算有效剂量,每张盲法图像对照欧洲指南标准的优化参考图像评分,采用Mann-Whitney U检验和线性回归分析。
  • 全国调查向80名放射科医生发送匿名问卷以了解现行实践。

关键影像表现/征象

  • PA较AP腰椎X线有效剂量降低41%(p<0.001),图像质量无差异(p=0.9)。
  • 调查21名放射科医生完成问卷,仅1家NHS信托目前使用PA。

临床应用与阅片要点

  • 作者认为应标准化为PA,以降低患者辐射暴露并改善患者安全。

局限性

  • 调查仅21名放射科医生完成问卷,样本量小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Phantom studies and a prior patient study have shown up to 53% effective dose reduction when lumbar spine radiographs are acquired posteroanterior (PA) instead of anteroposterior (AP). Since November 2017, Taunton and Somerset NHS Foundation Trust has acquired all standing lumbar spine radiographs PA. The aim of this study was to locally evaluate dose and image quality in both projections and survey current UK practice.

METHODS: 80 outpatients having a standing lumbar spine radiograph (40 AP; 40 PA) had their dose-area product recorded at a constant KV and focus film distance. Effective dose was calculated using PCXMC software. Each blinded radiograph was scored against an optimal reference image using European Guidelines criteria. The data were analyzed using Mann-Whitney U tests and linear regression. Eighty radiologists nationally were sent an anonymous survey to establish their current practice.

RESULTS: A lumbar spine radiograph acquired PA instead of AP reduced effective dose by 41% (p < 0.001) with no difference in image quality (p = 0.9). 21 radiologists completed our survey and only 1 NHS Trust is currently using PA.

CONCLUSION: PA lumbar spine radiography reduces patient radiation exposure with no affect on image quality, acquisition time or cost. The majority of NHS Trusts nationally are still using AP and it is time to standardize to PA.

ADVANCES IN KNOWLEDGE: This patient study provides further good evidence of how reduction in exposure to ionizing radiation can be achieved in lumbar spine radiography and more widespread adoption of PA protocol could improve patient safety.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Green C, Karnati G, Thomson K, et al. Lumbar spine radiographs - is it time for widespread adoption of posteroanterior projection? Br J Radiol. 2019. PMID: 31356113. doi:10.1259/bjr.20190386

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。